These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


173 related items for PubMed ID: 31691149

  • 1. Transpulmonary thermodilution before and during veno-venous extra-corporeal membrane oxygenation ECMO: an observational study on a potential loss of indicator into the extra-corporeal circuit.
    Herner A, Lahmer T, Mayr U, Rasch S, Schneider J, Schmid RM, Huber W.
    J Clin Monit Comput; 2020 Oct; 34(5):923-936. PubMed ID: 31691149
    [Abstract] [Full Text] [Related]

  • 2. Comparison of cardiac function index derived from femoral and jugular indicator injection for transpulmonary thermodilution with the PiCCO-device: A prospective observational study.
    Herner A, Heilmaier M, Mayr U, Schmid RM, Huber W.
    PLoS One; 2018 Oct; 13(7):e0200740. PubMed ID: 30063736
    [Abstract] [Full Text] [Related]

  • 3. Influence of different infracardial positions of central venous catheters in hemodynamic monitoring using the transpulmonal thermodilution method.
    Kellner P, Schleusener V, Bauerfeind F, Soukup J.
    J Clin Monit Comput; 2016 Oct; 30(5):629-40. PubMed ID: 26341509
    [Abstract] [Full Text] [Related]

  • 4. Comparison of global end-diastolic volume index derived from jugular and femoral indicator injection: a prospective observational study in patients equipped with both a PiCCO-2 and an EV-1000-device.
    Herner A, Heilmaier M, Mayr U, Schmid RM, Huber W.
    Sci Rep; 2020 Nov 27; 10(1):20773. PubMed ID: 33247165
    [Abstract] [Full Text] [Related]

  • 5. Transpulmonary thermodilution in patients treated with veno-venous extracorporeal membrane oxygenation.
    Loosen G, Conrad AM, Hagman M, Essert N, Thiel M, Luecke T, Krebs J.
    Ann Intensive Care; 2021 Jul 02; 11(1):101. PubMed ID: 34213674
    [Abstract] [Full Text] [Related]

  • 6. Room-temperature vs iced saline indicator injection for transpulmonary thermodilution.
    Huber W, Kraski T, Haller B, Mair S, Saugel B, Beitz A, Schmid RM, Malbrain ML.
    J Crit Care; 2014 Dec 02; 29(6):1133.e7-1133.e14. PubMed ID: 25240464
    [Abstract] [Full Text] [Related]

  • 7. Comparison of pulmonary vascular permeability index PVPI and global ejection fraction GEF derived from jugular and femoral indicator injection using the PiCCO-2 device: A prospective observational study.
    Huber W, Gruber A, Eckmann M, Elkmann F, Klein I, Lahmer T, Mayr U, Schellnegger R, Schneider J, Batres-Baires G, Fekecs L, Beitz A, Berbara H, Schmid R, Herner A.
    PLoS One; 2017 Dec 02; 12(10):e0178372. PubMed ID: 29040264
    [Abstract] [Full Text] [Related]

  • 8. In-parallel connected intermittent hemodialysis through ECMO does not affect hemodynamic parameters derived from transpulmonary thermodilution.
    Lahmer T, Mayr U, Rasch S, Batres Baires G, Schmid RM, Huber W.
    Perfusion; 2017 Nov 02; 32(8):702-705. PubMed ID: 28440110
    [Abstract] [Full Text] [Related]

  • 9. Transpulmonary thermodilution using femoral indicator injection: a prospective trial in patients with a femoral and a jugular central venous catheter.
    Saugel B, Umgelter A, Schuster T, Phillip V, Schmid RM, Huber W.
    Crit Care; 2010 Nov 02; 14(3):R95. PubMed ID: 20500825
    [Abstract] [Full Text] [Related]

  • 10. Femoral indicator injection for transpulmonary thermodilution using the EV1000/VolumeView(®): do the same criteria apply as for the PiCCO(®)?
    Huber W, Phillip V, Höllthaler J, Schultheiss C, Saugel B, Schmid RM.
    J Zhejiang Univ Sci B; 2016 Jul 02; 17(7):561-7. PubMed ID: 27381733
    [Abstract] [Full Text] [Related]

  • 11. Effects of changes in veno-venous extracorporeal membrane oxygenation blood flow on the measurement of intrathoracic blood volume and extravascular lung water index: a prospective interventional study.
    Conrad AM, Loosen G, Boesing C, Thiel M, Luecke T, Rocco PRM, Pelosi P, Krebs J.
    J Clin Monit Comput; 2023 Apr 02; 37(2):599-607. PubMed ID: 36284041
    [Abstract] [Full Text] [Related]

  • 12. [The influence of continuous venovenous hemofiltration on parameter measurement by the transpulmonary thermodilution technique].
    Wang Z, Li J, Qin Y, Xu L, Zhang J, Zhi Y.
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2015 Oct 02; 27(10):831-5. PubMed ID: 27132447
    [Abstract] [Full Text] [Related]

  • 13. Computed tomography to estimate cardiac preload and extravascular lung water. A retrospective analysis in critically ill patients.
    Saugel B, Holzapfel K, Stollfuss J, Schuster T, Phillip V, Schultheiss C, Schmid RM, Huber W.
    Scand J Trauma Resusc Emerg Med; 2011 May 23; 19():31. PubMed ID: 21605380
    [Abstract] [Full Text] [Related]

  • 14. Pulmonary vascular permeability index and global end-diastolic volume: are the data consistent in patients with femoral venous access for transpulmonary thermodilution: a prospective observational study.
    Berbara H, Mair S, Beitz A, Henschel B, Schmid RM, Huber W.
    BMC Anesthesiol; 2014 Sep 24; 14():81. PubMed ID: 25928560
    [Abstract] [Full Text] [Related]

  • 15. Impact of misplaced subclavian vein catheter into jugular vein on transpulmonary thermodilution measurement variables.
    Yu WQ, Zhang Y, Zhang SY, Liang ZY, Fu SQ, Xu J, Liang TB.
    J Zhejiang Univ Sci B; 2016 Jan 24; 17(1):60-6. PubMed ID: 26739527
    [Abstract] [Full Text] [Related]

  • 16. Transpulmonary thermodilution measurements are not affected by continuous veno-venous hemofiltration at high blood pump flow.
    Dufour N, Delville M, Teboul JL, Camous L, Favier du Noyer A, Richard C, Monnet X.
    Intensive Care Med; 2012 Jul 24; 38(7):1162-8. PubMed ID: 22543424
    [Abstract] [Full Text] [Related]

  • 17. Influence of the central venous site on the transpulmonary thermodilution parameters in critically ill burn patients.
    Soussi S, Sisso F, Maurel V, Oueslati H, Legrand M.
    Burns; 2015 Nov 24; 41(7):1607-10. PubMed ID: 26771037
    [Abstract] [Full Text] [Related]

  • 18. [Pulse indicator continuous cardiac output measurement-guided treatment aids two pediatric patients with severe acute pancreatitis complicated with acute respiratory distress syndrome].
    Yan W, Wang L.
    Zhonghua Er Ke Za Zhi; 2014 Sep 24; 52(9):693-8. PubMed ID: 25476433
    [Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20. Consistency of cardiac function index and global ejection fraction with global end-diastolic volume in patients with femoral central venous access for transpulmonary thermodilution: a prospective observational study.
    Beitz A, Berbara H, Mair S, Henschel B, Lahmer T, Rasch S, Schmid R, Huber W.
    J Clin Monit Comput; 2017 Jun 24; 31(3):599-605. PubMed ID: 27103253
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 9.