These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
173 related items for PubMed ID: 31725175
21. Bivariate marker measurements and ROC analysis. Wang MC, Li S. Biometrics; 2012 Dec; 68(4):1207-18. PubMed ID: 23005264 [Abstract] [Full Text] [Related]
22. A unified Bayesian framework for exact inference of area under the receiver operating characteristic curve. Lin R, Chan KG, Shi H. Stat Methods Med Res; 2021 Oct; 30(10):2269-2287. PubMed ID: 34468238 [Abstract] [Full Text] [Related]
23. Time-dependent ROC curve estimation for interval-censored data. Beyene KM, El Ghouch A. Biom J; 2022 Aug; 64(6):1056-1074. PubMed ID: 35523738 [Abstract] [Full Text] [Related]
25. Estimation of smooth ROC curves for biomarkers with limits of detection. Bantis LE, Yan Q, Tsimikas JV, Feng Z. Stat Med; 2017 Oct 30; 36(24):3830-3843. PubMed ID: 28786136 [Abstract] [Full Text] [Related]
31. The average receiver operating characteristic curve in multireader multicase imaging studies. Chen W, Samuelson FW. Br J Radiol; 2014 Aug 30; 87(1040):20140016. PubMed ID: 24884728 [Abstract] [Full Text] [Related]
32. Comparison of two correlated ROC curves at a given specificity or sensitivity level. Bantis LE, Feng Z. Stat Med; 2016 Oct 30; 35(24):4352-4367. PubMed ID: 27324068 [Abstract] [Full Text] [Related]
33. Restricted ROC curves are useful tools to evaluate the performance of tumour markers. Parodi S, Muselli M, Carlini B, Fontana V, Haupt R, Pistoia V, Corrias MV. Stat Methods Med Res; 2016 Feb 30; 25(1):294-314. PubMed ID: 22735161 [Abstract] [Full Text] [Related]
34. ROC curve estimation under test-result-dependent sampling. Wang X, Ma J, George SL. Biostatistics; 2013 Jan 30; 14(1):160-72. PubMed ID: 22723502 [Abstract] [Full Text] [Related]
35. More efficient estimators of the area under the receiver operating characteristic curve in paired ranked set sampling. Abdallah MS. Stat Methods Med Res; 2023 Jun 30; 32(6):1217-1233. PubMed ID: 37032644 [Abstract] [Full Text] [Related]
38. A model for adjusting for nonignorable verification bias in estimation of the ROC curve and its area with likelihood-based approach. Liu D, Zhou XH. Biometrics; 2010 Dec 30; 66(4):1119-28. PubMed ID: 20222937 [Abstract] [Full Text] [Related]
39. Jackknife variance of the partial area under the empirical receiver operating characteristic curve. Bandos AI, Guo B, Gur D. Stat Methods Med Res; 2017 Apr 30; 26(2):528-541. PubMed ID: 25228637 [Abstract] [Full Text] [Related]