These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
404 related items for PubMed ID: 31736146
21. MR fingerprinting for rapid quantification of myocardial T1 , T2 , and proton spin density. Hamilton JI, Jiang Y, Chen Y, Ma D, Lo WC, Griswold M, Seiberlich N. Magn Reson Med; 2017 Apr; 77(4):1446-1458. PubMed ID: 27038043 [Abstract] [Full Text] [Related]
22. Free-breathing 3D whole-heart joint T1/T2 mapping and water/fat imaging at 0.55 T. Si D, Crabb MG, Kunze KP, Littlewood SJ, Prieto C, Botnar RM. Magn Reson Med; 2024 Oct; 92(4):1511-1524. PubMed ID: 38872384 [Abstract] [Full Text] [Related]
23. Deep Learning for Inference of Hepatic Proton Density Fat Fraction From T1-Weighted In-Phase and Opposed-Phase MRI: Retrospective Analysis of Population-Based Trial Data. Wang K, Cunha GM, Hasenstab K, Henderson WC, Middleton MS, Cole SA, Umans JG, Ali T, Hsiao A, Sirlin CB. AJR Am J Roentgenol; 2023 Nov; 221(5):620-631. PubMed ID: 37466189 [Abstract] [Full Text] [Related]
24. Magnetic resonance fingerprinting with dictionary-based fat and water separation (DBFW MRF): A multi-component approach. Cencini M, Biagi L, Kaggie JD, Schulte RF, Tosetti M, Buonincontri G. Magn Reson Med; 2019 May; 81(5):3032-3045. PubMed ID: 30578569 [Abstract] [Full Text] [Related]
26. Comparison of Multi-Echo Dixon Methods with Volume Interpolated Breath-Hold Gradient Echo Magnetic Resonance Imaging in Fat-Signal Fraction Quantification of Paravertebral Muscle. Yoo YH, Kim HS, Lee YH, Yoon CS, Paek MY, Yoo H, Kannengiesser S, Chung TS, Song HT, Suh JS, Kim S. Korean J Radiol; 2015 May; 16(5):1086-95. PubMed ID: 26357503 [Abstract] [Full Text] [Related]
27. Magnetization-prepared GRASP MRI for rapid 3D T1 mapping and fat/water-separated T1 mapping. Feng L, Liu F, Soultanidis G, Liu C, Benkert T, Block KT, Fayad ZA, Yang Y. Magn Reson Med; 2021 Jul; 86(1):97-114. PubMed ID: 33580909 [Abstract] [Full Text] [Related]
28. 3D SASHA myocardial T1 mapping with high accuracy and improved precision. Nordio G, Bustin A, Henningsson M, Rashid I, Chiribiri A, Ismail T, Odille F, Prieto C, Botnar RM. MAGMA; 2019 Apr; 32(2):281-289. PubMed ID: 30191345 [Abstract] [Full Text] [Related]
29. Free-breathing simultaneous native myocardial T1, T2 and T1ρ mapping with Cartesian acquisition and dictionary matching. Lyu Z, Hua S, Xu J, Shen Y, Guo R, Hu P, Qi H. J Cardiovasc Magn Reson; 2023 Nov 09; 25(1):63. PubMed ID: 37946191 [Abstract] [Full Text] [Related]
30. Evaluation of liver T1 using MOLLI gradient echo readout under the influence of fat. Liu CY, Noda C, Ambale-Venkatesh B, Kassai Y, Bluemke D, Lima JAC. Magn Reson Imaging; 2022 Jan 09; 85():57-63. PubMed ID: 34678435 [Abstract] [Full Text] [Related]
31. Free-breathing simultaneous water-fat separation and T1 mapping of the whole liver (SWALI) with isotropic resolution using 3D golden-angle radial trajectory. Wang Y, Qi H, Wang Y, Xiao M, Xiang C, Dong J, Chen H. Quant Imaging Med Surg; 2023 Feb 01; 13(2):912-923. PubMed ID: 36819282 [Abstract] [Full Text] [Related]
32. Spiral blurring correction with water-fat separation for magnetic resonance fingerprinting in the breast. Nolte T, Gross-Weege N, Doneva M, Koken P, Elevelt A, Truhn D, Kuhl C, Schulz V. Magn Reson Med; 2020 Apr 01; 83(4):1192-1207. PubMed ID: 31631385 [Abstract] [Full Text] [Related]
33. Free-breathing, fat-corrected T1 mapping of the liver with stack-of-stars MRI, and joint estimation of T1, PDFF, R2* , and B1+. Muslu Y, Tamada D, Roberts NT, Cashen TA, Mandava S, Kecskemeti SR, Hernando D, Reeder SB. Magn Reson Med; 2024 Nov 01; 92(5):1913-1932. PubMed ID: 38923009 [Abstract] [Full Text] [Related]
34. Quantitative Skeletal Muscle Imaging Using 3D MR Fingerprinting With Water and Fat Separation. Marty B, Lopez Kolkovsky AL, Araujo ECA, Reyngoudt H. J Magn Reson Imaging; 2021 May 01; 53(5):1529-1538. PubMed ID: 32996670 [Abstract] [Full Text] [Related]
35. Evaluation of six-point modified dixon and magnetic resonance spectroscopy for fat quantification: a fat-water-iron phantom study. Fukuzawa K, Hayashi T, Takahashi J, Yoshihara C, Tano M, Kotoku J, Saitoh S. Radiol Phys Technol; 2017 Sep 01; 10(3):349-358. PubMed ID: 28770394 [Abstract] [Full Text] [Related]
36. Motion-resolved fat-fraction mapping with whole-heart free-running multiecho GRE and pilot tone. Mackowiak ALC, Roy CW, Yerly J, Falcão MBL, Bacher M, Speier P, Piccini D, Stuber M, Bastiaansen JAM. Magn Reson Med; 2023 Sep 01; 90(3):922-938. PubMed ID: 37103471 [Abstract] [Full Text] [Related]
37. Free-breathing multitasking multi-echo MRI for whole-liver water-specific T1 , proton density fat fraction, and R2∗ quantification. Wang N, Cao T, Han F, Xie Y, Zhong X, Ma S, Kwan A, Fan Z, Han H, Bi X, Noureddin M, Deshpande V, Christodoulou AG, Li D. Magn Reson Med; 2022 Jan 01; 87(1):120-137. PubMed ID: 34418152 [Abstract] [Full Text] [Related]
38. Reference Values for Water-Specific T1 of the Liver at 3 T: T2*-Compensation and the Confounding Effects of Fat. Thompson RB, Sherrington R, Beaulieu C, Kirkham A, Paterson DI, Seres P, Grenier J. J Magn Reson Imaging; 2024 Nov 01; 60(5):2063-2075. PubMed ID: 38305588 [Abstract] [Full Text] [Related]
39. Accelerated liver water T1 mapping using single-shot continuous inversion-recovery spiral imaging. Huaroc Moquillaza E, Weiss K, Stelter J, Steinhelfer L, Lee YJ, Amthor T, Koken P, Makowski MR, Braren R, Doneva M, Karampinos DC. NMR Biomed; 2024 May 01; 37(5):e5097. PubMed ID: 38269568 [Abstract] [Full Text] [Related]
40. Whole-heart T1 mapping using a 2D fat image navigator for respiratory motion compensation. Nordio G, Schneider T, Cruz G, Correia T, Bustin A, Prieto C, Botnar RM, Henningsson M. Magn Reson Med; 2020 Jan 01; 83(1):178-187. PubMed ID: 31400054 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]