These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


404 related items for PubMed ID: 31736146

  • 41. Improved accuracy and precision with three-parameter simultaneous myocardial T1 and T2 mapping using multiparametric SASHA.
    Chow K, Hayes G, Flewitt JA, Feuchter P, Lydell C, Howarth A, Pagano JJ, Thompson RB, Kellman P, White JA.
    Magn Reson Med; 2022 Jun; 87(6):2775-2791. PubMed ID: 35133018
    [Abstract] [Full Text] [Related]

  • 42. Fast multi-parametric imaging in abdomen by B 1 + corrected dual-flip angle sequence with interleaved echo acquisition.
    Peng H, Cheng C, Wan Q, Jia S, Wang S, Lv J, Liang D, Liu W, Liu X, Zheng H, Zou C.
    Magn Reson Med; 2022 May; 87(5):2194-2208. PubMed ID: 34888911
    [Abstract] [Full Text] [Related]

  • 43. Clinical feasibility of 3D-QALAS - Single breath-hold 3D myocardial T1- and T2-mapping.
    Kvernby S, Warntjes M, Engvall J, Carlhäll CJ, Ebbers T.
    Magn Reson Imaging; 2017 May; 38():13-20. PubMed ID: 27998745
    [Abstract] [Full Text] [Related]

  • 44. Cardiac MR fingerprinting with a short acquisition window in consecutive patients referred for clinical CMR and healthy volunteers.
    Rumac S, Pavon AG, Hamilton JI, Rodrigues D, Seiberlich N, Schwitter J, van Heeswijk RB.
    Sci Rep; 2022 Nov 04; 12(1):18705. PubMed ID: 36333385
    [Abstract] [Full Text] [Related]

  • 45.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 46. Confounder-corrected T1 mapping in the liver through simultaneous estimation of T1 , PDFF, R 2 * , and B 1 + in a single breath-hold acquisition.
    Roberts NT, Tamada D, Muslu Y, Hernando D, Reeder SB.
    Magn Reson Med; 2023 Jun 04; 89(6):2186-2203. PubMed ID: 36656152
    [Abstract] [Full Text] [Related]

  • 47. Free-running 3D whole heart myocardial T1 mapping with isotropic spatial resolution.
    Qi H, Jaubert O, Bustin A, Cruz G, Chen H, Botnar R, Prieto C.
    Magn Reson Med; 2019 Oct 04; 82(4):1331-1342. PubMed ID: 31099442
    [Abstract] [Full Text] [Related]

  • 48.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 49.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 50.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 51.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 52.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 53. Water-Fat Separation in MR Fingerprinting for Quantitative Monitoring of the Skeletal Muscle in Neuromuscular Disorders.
    Marty B, Reyngoudt H, Boisserie JM, Le Louër J, C A Araujo E, Fromes Y, Carlier PG.
    Radiology; 2021 Sep 04; 300(3):652-660. PubMed ID: 34254855
    [Abstract] [Full Text] [Related]

  • 54. Accelerated free-breathing whole-heart 3D T2 mapping with high isotropic resolution.
    Bustin A, Milotta G, Ismail TF, Neji R, Botnar RM, Prieto C.
    Magn Reson Med; 2020 Mar 04; 83(3):988-1002. PubMed ID: 31535729
    [Abstract] [Full Text] [Related]

  • 55.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 56.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 57. Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS.
    Kvernby S, Warntjes MJ, Haraldsson H, Carlhäll CJ, Engvall J, Ebbers T.
    J Cardiovasc Magn Reson; 2014 Dec 20; 16(1):102. PubMed ID: 25526880
    [Abstract] [Full Text] [Related]

  • 58.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 59.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 60. Free-breathing three-dimensional simultaneous myocardial T1 and T2 mapping based on multi-parametric SAturation-recovery and Variable-flip-Angle.
    Si D, Guo R, Cheng L, Kong X, Herzka DA, Ding H.
    J Cardiovasc Magn Reson; 2014 Dec 20; 26(2):101065. PubMed ID: 39059610
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 21.