These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


289 related items for PubMed ID: 31812360

  • 21. Influence of CBCT enhancement filters on diagnosis of vertical root fractures: a simulation study in endodontically treated teeth with and without intracanal posts.
    Ferreira LM, Visconti MA, Nascimento HA, Dallemolle RR, Ambrosano GM, Freitas DQ.
    Dentomaxillofac Radiol; 2015; 44(5):20140352. PubMed ID: 25666446
    [Abstract] [Full Text] [Related]

  • 22. Diagnostic efficacy of cone-beam computed tomography for detection of vertical root fractures in endodontically treated teeth: a systematic review.
    Habibzadeh S, Ghoncheh Z, Kabiri P, Mosaddad SA.
    BMC Med Imaging; 2023 Jun 01; 23(1):68. PubMed ID: 37264339
    [Abstract] [Full Text] [Related]

  • 23. Diagnosis of Mesiodistal Vertical Root Fractures in Teeth with Metal Posts: Influence of Applying Filters in Cone-beam Computed Tomography Images at Different Resolutions.
    De Martin E Silva D, Campos CN, Pires Carvalho AC, Devito KL.
    J Endod; 2018 Mar 01; 44(3):470-474. PubMed ID: 29153985
    [Abstract] [Full Text] [Related]

  • 24. Influence of the metal post material, tooth location in the dental arch, and metal artifact reduction tool on vertical root fracture diagnosis in cone beam CT.
    Rosado LPL, Fontenele RC, Farias-Gomes A, Freitas DQ, Neves FS.
    Odontology; 2024 Jul 01; 112(3):959-965. PubMed ID: 38214844
    [Abstract] [Full Text] [Related]

  • 25. Assessment of the Metal Artifact Reduction Tool for the Detection of Root Isthmus in Mandibular Molars with Intraradicular Posts in Cone-beam Computed Tomographic Scans.
    Barros de Oliveira ML, Junqueira RB, Kamburoğlu K, Eratam N, Çakmak EE, Sönmez G, Küçük Ö, Verner FS.
    J Endod; 2021 Oct 01; 47(10):1583-1591. PubMed ID: 34265325
    [Abstract] [Full Text] [Related]

  • 26. The influence of voxel size and artifact reduction on the detection of vertical root fracture in endodontically treated teeth.
    Uysal S, Akcicek G, Yalcin ED, Tuncel B, Dural S.
    Acta Odontol Scand; 2021 Jul 01; 79(5):354-358. PubMed ID: 33337942
    [Abstract] [Full Text] [Related]

  • 27. Detection of Vertical Root Fractures Using Cone-Beam Computed Tomography in the Presence and Absence of Gutta-Percha.
    Hekmatian E, Karbasi Kheir M, Fathollahzade H, Sheikhi M.
    ScientificWorldJournal; 2018 Jul 01; 2018():1920946. PubMed ID: 30111988
    [Abstract] [Full Text] [Related]

  • 28. Accuracy of detecting vertical root fractures in non-root filled teeth using cone beam computed tomography: effect of voxel size and fracture width.
    Guo XL, Li G, Zheng JQ, Ma RH, Liu FC, Yuan FS, Lyu PJ, Guo YJ, Yin S.
    Int Endod J; 2019 Jun 01; 52(6):887-898. PubMed ID: 30661246
    [Abstract] [Full Text] [Related]

  • 29. Evaluation of three imaging techniques for the detection of vertical root fractures in the absence and presence of gutta-percha root fillings.
    Khedmat S, Rouhi N, Drage N, Shokouhinejad N, Nekoofar MH.
    Int Endod J; 2012 Nov 01; 45(11):1004-9. PubMed ID: 22551491
    [Abstract] [Full Text] [Related]

  • 30. Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth.
    Bechara B, McMahan CA, Noujeim M, Faddoul T, Moore WS, Teixeira FB, Geha H.
    Dentomaxillofac Radiol; 2013 Nov 01; 42(7):20120404. PubMed ID: 23625067
    [Abstract] [Full Text] [Related]

  • 31. Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth.
    Bechara B, Alex McMahan C, Moore WS, Noujeim M, Teixeira FB, Geha H.
    Dentomaxillofac Radiol; 2013 Nov 01; 42(5):20120245. PubMed ID: 23520395
    [Abstract] [Full Text] [Related]

  • 32. Effect of digital enhancement on the radiographic assessment of vertical root fractures in the presence of different intracanal materials: an in vitro study.
    Gaêta-Araujo H, Nascimento EHL, Oliveira-Santos N, Queiroz PM, Oliveira ML, Freitas DQ, Oliveira-Santos C.
    Clin Oral Investig; 2021 Jan 01; 25(1):195-202. PubMed ID: 32506327
    [Abstract] [Full Text] [Related]

  • 33. Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures.
    Caetano AP, Sousa TO, Oliveira MR, Evanglista K, Bueno JM, Silva MA.
    Dentomaxillofac Radiol; 2021 Mar 01; 50(3):20200334. PubMed ID: 33259236
    [Abstract] [Full Text] [Related]

  • 34. The detection of vertical root fractures in root filled teeth with periapical radiographs and CBCT scans.
    Patel S, Brady E, Wilson R, Brown J, Mannocci F.
    Int Endod J; 2013 Dec 01; 46(12):1140-52. PubMed ID: 23617242
    [Abstract] [Full Text] [Related]

  • 35. Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts.
    Bezerra IS, Neves FS, Vasconcelos TV, Ambrosano GM, Freitas DQ.
    Dentomaxillofac Radiol; 2015 Dec 01; 44(6):20140428. PubMed ID: 25764360
    [Abstract] [Full Text] [Related]

  • 36. Effect of different intracanal posts and exposure parameters on detection of vertical root fractures by cone-beam computed tomography.
    Shokri A, Eskandarloo A, Zahedi F, Karkehabadi H, Foroozandeh M, Farhadian M.
    Aust Endod J; 2023 Sep 01; 49 Suppl 1():132-145. PubMed ID: 36269003
    [Abstract] [Full Text] [Related]

  • 37. In Vivo Detection of Subtle Vertical Root Fracture in Endodontically Treated Teeth by Cone-beam Computed Tomography.
    Zhang L, Wang T, Cao Y, Wang C, Tan B, Tang X, Tan R, Lin Z.
    J Endod; 2019 Jul 01; 45(7):856-862. PubMed ID: 31030978
    [Abstract] [Full Text] [Related]

  • 38. Do the tube current and metal artifact reduction influence the diagnosis of vertical root fracture in a tooth positioned in the vicinity of a zirconium implant? A CBCT study.
    Fontenele RC, Farias Gomes A, Nejaim Y, Freitas DQ.
    Clin Oral Investig; 2021 Apr 01; 25(4):2229-2235. PubMed ID: 32827079
    [Abstract] [Full Text] [Related]

  • 39. Impact of root fillings and posts on the diagnostic ability of three intra-oral digital radiographic systems in detecting vertical root fractures.
    Nascimento HA, Neves FS, de-Azevedo-Vaz SL, Duque TM, Ambrosano GM, Freitas DQ.
    Int Endod J; 2015 Sep 01; 48(9):864-71. PubMed ID: 25251773
    [Abstract] [Full Text] [Related]

  • 40. Detection of vertical root fractures in vivo in endodontically treated teeth by cone-beam computed tomography scans.
    Metska ME, Aartman IH, Wesselink PR, Özok AR.
    J Endod; 2012 Oct 01; 38(10):1344-7. PubMed ID: 22980175
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 15.