These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
414 related items for PubMed ID: 32050836
1. Changes in cardiac output with hemodialysis relate to net volume balance and to inferior vena cava ultrasound collapsibility in critically ill patients. Kaptein MJ, Kaptein JS, Nguyen CD, Oo Z, Thwe PP, Thu MB, Kaptein EM. Ren Fail; 2020 Nov; 42(1):179-192. PubMed ID: 32050836 [Abstract] [Full Text] [Related]
2. Relationship of inferior vena cava collapsibility to ultrafiltration volume achieved in critically ill hemodialysis patients. Kaptein MJ, Kaptein JS, Oo Z, Kaptein EM. Int J Nephrol Renovasc Dis; 2018 Nov; 11():195-209. PubMed ID: 30087575 [Abstract] [Full Text] [Related]
3. Influence of head-of-bed elevation on the measurement of inferior vena cava diameter and collapsibility. Bondarsky E, Rothman A, Ramesh N, Love A, Kory P, Lee YI. J Clin Ultrasound; 2020 Jun; 48(5):249-253. PubMed ID: 32017142 [Abstract] [Full Text] [Related]
5. Ultrasound-based clinical profiles for predicting the risk of intradialytic hypotension in critically ill patients on intermittent dialysis: a prospective observational study. da Hora Passos R, Caldas J, Ramos JGR, Dos Santos Galvão de Melo EB, Ribeiro MPD, Alves MFC, Batista PBP, Messeder OHC, de Carvalho de Farias AM, Macedo E, Rouby JJ. Crit Care; 2019 Dec 02; 23(1):389. PubMed ID: 31791373 [Abstract] [Full Text] [Related]
8. Handcarried ultrasound measurement of the inferior vena cava for assessment of intravascular volume status in the outpatient hemodialysis clinic. Brennan JM, Ronan A, Goonewardena S, Blair JE, Hammes M, Shah D, Vasaiwala S, Kirkpatrick JN, Spencer KT. Clin J Am Soc Nephrol; 2006 Jul 02; 1(4):749-53. PubMed ID: 17699282 [Abstract] [Full Text] [Related]
9. Prospective evaluation of intravascular volume status in critically ill patients: does inferior vena cava collapsibility correlate with central venous pressure? Stawicki SP, Adkins EJ, Eiferman DS, Evans DC, Ali NA, Njoku C, Lindsey DE, Cook CH, Balakrishnan JM, Valiaveedan S, Galwankar SC, Boulger CT, Springer AN, Bahner DP. J Trauma Acute Care Surg; 2014 Apr 02; 76(4):956-63; discussion 963-4. PubMed ID: 24662857 [Abstract] [Full Text] [Related]
14. Can a renal nurse assess fluid status using ultrasound on the inferior vena cava? A cross-sectional interrater study. Steinwandel U, Gibson N, Towell A, Rippey JJR, Rosman J. Hemodial Int; 2018 Apr 02; 22(2):261-269. PubMed ID: 29024379 [Abstract] [Full Text] [Related]
16. Does bedside sonographic measurement of the inferior vena cava diameter correlate with central venous pressure in the assessment of intravascular volume in children? Ng L, Khine H, Taragin BH, Avner JR, Ushay M, Nunez D. Pediatr Emerg Care; 2013 Mar 02; 29(3):337-41. PubMed ID: 23426248 [Abstract] [Full Text] [Related]
17. Echography of the inferior vena cava for estimating fluid removal from patients undergoing hemodialysis. Kusaba T, Yamaguchi K, Oda H. Nihon Jinzo Gakkai Shi; 1996 Mar 02; 38(3):119-23. PubMed ID: 8721332 [Abstract] [Full Text] [Related]
18. Measurements of Inferior Vena Cava Diameter for Prediction of Hypotension and Bradycardia during Spinal Anesthesia in Spontaneously Breathing Patients during Elective Knee Joint Replacement Surgery. Mačiulienė A, Gelmanas A, Jaremko I, Tamošiūnas R, Smailys A, Macas A. Medicina (Kaunas); 2018 Jul 12; 54(3):. PubMed ID: 30344280 [Abstract] [Full Text] [Related]