These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


271 related items for PubMed ID: 32074256

  • 1. Effectiveness of Implanted Cardiac Rhythm Recorders With Electrocardiographic Monitoring for Detecting Arrhythmias in Pregnant Women With Symptomatic Arrhythmia and/or Structural Heart Disease: A Randomized Clinical Trial.
    Sliwa K, Azibani F, Johnson MR, Viljoen C, Baard J, Osman A, Briton O, Ntsekhe M, Chin A.
    JAMA Cardiol; 2020 Apr 01; 5(4):458-463. PubMed ID: 32074256
    [Abstract] [Full Text] [Related]

  • 2. Effectiveness of implantable loop recorder and Holter electrocardiographic monitoring for the detection of arrhythmias in patients with peripartum cardiomyopathy.
    Hoevelmann J, Sliwa K, Briton O, Ntsekhe M, Chin A, Viljoen C.
    Clin Res Cardiol; 2023 Mar 01; 112(3):379-391. PubMed ID: 36131137
    [Abstract] [Full Text] [Related]

  • 3. Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring.
    Barrett PM, Komatireddy R, Haaser S, Topol S, Sheard J, Encinas J, Fought AJ, Topol EJ.
    Am J Med; 2014 Jan 01; 127(1):95.e11-7. PubMed ID: 24384108
    [Abstract] [Full Text] [Related]

  • 4. Intermittent short ECG recording is more effective than 24-hour Holter ECG in detection of arrhythmias.
    Hendrikx T, Rosenqvist M, Wester P, Sandström H, Hörnsten R.
    BMC Cardiovasc Disord; 2014 Apr 01; 14():41. PubMed ID: 24690488
    [Abstract] [Full Text] [Related]

  • 5. The utility of implantable loop recorders for diagnosing unexplained syncope in 100 consecutive patients: five-year, single-center experience.
    Inamdar V, Mehta S, Juang G, Cohen T.
    J Invasive Cardiol; 2006 Jul 01; 18(7):313-5. PubMed ID: 16816436
    [Abstract] [Full Text] [Related]

  • 6. Cardiac event recorders yield more diagnoses and are more cost-effective than 48-hour Holter monitoring in patients with palpitations. A controlled clinical trial.
    Kinlay S, Leitch JW, Neil A, Chapman BL, Hardy DB, Fletcher PJ.
    Ann Intern Med; 1996 Jan 01; 124(1 Pt 1):16-20. PubMed ID: 7503472
    [Abstract] [Full Text] [Related]

  • 7. A randomised controlled trial evaluating arrhythmia burden, risk of sudden cardiac death and stroke in patients with Fabry disease: the role of implantable loop recorders (RaILRoAD) compared with current standard practice.
    Vijapurapu R, Kozor R, Hughes DA, Woolfson P, Jovanovic A, Deegan P, Rusk R, Figtree GA, Tchan M, Whalley D, Kotecha D, Leyva F, Moon J, Geberhiwot T, Steeds RP.
    Trials; 2019 May 31; 20(1):314. PubMed ID: 31151481
    [Abstract] [Full Text] [Related]

  • 8. Obstructive Sleep Apnoea and Cardiac Arrhythmias (OSCA) trial: a nested cohort study using injectable loop recorders and Holter monitoring in patients with obstructive sleep apnoea.
    He H, Lachlan T, Chandan N, Lim VG, Kimani P, Ng GA, Ali A, Randeva H, Osman F.
    BMJ Open; 2023 Feb 15; 13(2):e070884. PubMed ID: 36792325
    [Abstract] [Full Text] [Related]

  • 9. Implantable loop recorder for monitoring patients with congenital heart disease.
    Huntgeburth M, Hohmann C, Ewert P, Freilinger S, Nagdyman N, Neidenbach R, Pieper L, Pieringer F, Lennerz C, Kaemmerer H, Kolb C.
    Cardiovasc Diagn Ther; 2021 Dec 15; 11(6):1334-1343. PubMed ID: 35070802
    [Abstract] [Full Text] [Related]

  • 10. Detection of arrhythmias in adult congenital heart disease patients with LINQTM implantable loop recorder.
    Dodeja AK, Thomas C, Daniels CJ, Kertesz N, Kamp A.
    Congenit Heart Dis; 2019 Sep 15; 14(5):745-751. PubMed ID: 31313513
    [Abstract] [Full Text] [Related]

  • 11. Extended ECG monitoring with an implantable loop recorder in patients with cryptogenic stroke: time schedule, reasons for explantation and incidental findings (results from the TRACK-AF trial).
    Bettin M, Dechering D, Kochhäuser S, Bode N, Eckardt L, Frommeyer G, Reinke F.
    Clin Res Cardiol; 2019 Mar 15; 108(3):309-314. PubMed ID: 30167809
    [Abstract] [Full Text] [Related]

  • 12. Use of implantable loop recorders in patients with Brugada syndrome and suspected risk of ventricular arrhythmia.
    Kubala M, Aïssou L, Traullé S, Gugenheim AL, Hermida JS.
    Europace; 2012 Jun 15; 14(6):898-902. PubMed ID: 21979995
    [Abstract] [Full Text] [Related]

  • 13. Comparison of the patient-activated event recording system vs. traditional 24 h Holter electrocardiography in individuals with paroxysmal palpitations or dizziness.
    de Asmundis C, Conte G, Sieira J, Chierchia GB, Rodriguez-Manero M, Di Giovanni G, Ciconte G, Levinstein M, Baltogiannis G, Saitoh Y, Casado-Arroyo R, Brugada P.
    Europace; 2014 Aug 15; 16(8):1231-5. PubMed ID: 24574492
    [Abstract] [Full Text] [Related]

  • 14. Diagnostic value of implantable loop recorders in patients with unexplained syncope or palpitations.
    Radovanović NN, Pavlović SU, Kirćanski B, Branković N, Vujadinović N, Sajić V, Milašinović A, Bisenić V, Živković M, Milašinović G.
    Ann Noninvasive Electrocardiol; 2021 Sep 15; 26(5):e12864. PubMed ID: 34097780
    [Abstract] [Full Text] [Related]

  • 15. Efficacy of implantable loop recorders in establishing symptom-rhythm correlation in young patients with syncope and palpitations.
    Rossano J, Bloemers B, Sreeram N, Balaji S, Shah MJ.
    Pediatrics; 2003 Sep 15; 112(3 Pt 1):e228-33. PubMed ID: 12949317
    [Abstract] [Full Text] [Related]

  • 16. The quality of ECG data acquisition, and diagnostic performance of a novel adhesive patch for ambulatory cardiac rhythm monitoring in arrhythmia detection.
    Karaoğuz MR, Yurtseven E, Aslan G, Deliormanlı BG, Adıgüzel Ö, Gönen M, Li KM, Yılmaz EN.
    J Electrocardiol; 2019 Sep 15; 54():28-35. PubMed ID: 30851474
    [Abstract] [Full Text] [Related]

  • 17. [Holter monitoring in patients with focal cerebral ischaemic attacks (author's transl)].
    Tonet JL, Frank R, Ducardonnet A, Fillette F, Fontaine G, Komajda M, Thomas D, Bousser MG, Grosgogeat Y.
    Nouv Presse Med; 2019 Sep 15; 10(30):2491-4. PubMed ID: 6167934
    [Abstract] [Full Text] [Related]

  • 18. Cardiac Rhythm Disturbances in Hemodialysis Patients: Early Detection Using an Implantable Loop Recorder and Correlation With Biological and Dialysis Parameters.
    Sacher F, Jesel L, Borni-Duval C, De Precigout V, Lavainne F, Bourdenx JP, Haddj-Elmrabet A, Seigneuric B, Keller A, Ott J, Savel H, Delmas Y, Bazin-Kara D, Klotz N, Ploux S, Buffler S, Ritter P, Rondeau V, Bordachar P, Martin C, Deplagne A, Reuter S, Haissaguerre M, Gourraud JB, Vigneau C, Mabo P, Maury P, Hannedouche T, Benard A, Combe C.
    JACC Clin Electrophysiol; 2018 Mar 15; 4(3):397-408. PubMed ID: 30089568
    [Abstract] [Full Text] [Related]

  • 19. Comparison of Arrhythmia Detection by 24-Hour Holter and 14-Day Continuous Electrocardiography Patch Monitoring.
    Chua SK, Chen LC, Lien LM, Lo HM, Liao ZY, Chao SP, Chuang CY, Chiu CZ.
    Acta Cardiol Sin; 2020 May 15; 36(3):251-259. PubMed ID: 32425440
    [Abstract] [Full Text] [Related]

  • 20. An unmet need: arrhythmia detection by implantable loop recorder in the systemic right ventricle.
    Kakarla J, Crossland DS, Murray S, Adhvaryu K, Jansen K, Rybicka J, Hermuzi A, Martin R, Shepherd E, Seller N, Coats L.
    Europace; 2023 Nov 02; 25(11):. PubMed ID: 37816150
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 14.