These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Quantitative Prediction of Paravalvular Leak in Transcatheter Aortic Valve Replacement Based on Tissue-Mimicking 3D Printing. Qian Z, Wang K, Liu S, Zhou X, Rajagopal V, Meduri C, Kauten JR, Chang YH, Wu C, Zhang C, Wang B, Vannan MA. JACC Cardiovasc Imaging; 2017 Jul; 10(7):719-731. PubMed ID: 28683947 [Abstract] [Full Text] [Related]
3. Pre-procedural fit-testing of TAVR valves using parametric modeling and 3D printing. Hosny A, Dilley JD, Kelil T, Mathur M, Dean MN, Weaver JC, Ripley B. J Cardiovasc Comput Tomogr; 2019 Jul; 13(1):21-30. PubMed ID: 30322772 [Abstract] [Full Text] [Related]
5. Practical determination of aortic valve calcium volume score on contrast-enhanced computed tomography prior to transcatheter aortic valve replacement and impact on paravalvular regurgitation: Elucidating optimal threshold cutoffs. Bettinger N, Khalique OK, Krepp JM, Hamid NB, Bae DJ, Pulerwitz TC, Liao M, Hahn RT, Vahl TP, Nazif TM, George I, Leon MB, Einstein AJ, Kodali SK. J Cardiovasc Comput Tomogr; 2017 Apr; 11(4):302-308. PubMed ID: 28457950 [Abstract] [Full Text] [Related]
6. Comparison of self-expanding and balloon-expandable transcatheter aortic valves morphology and association with paravalvular regurgitation: Evaluation using multidetector computed tomography. Almeida JG, Ferreira SM, Fonseca P, Dias T, Guerreiro C, Barbosa A, Teixeira P, Carvalho M, Ferreira W, Ferreira ND, Braga P, Ribeiro J, Ribeiro VG. Catheter Cardiovasc Interv; 2018 Sep 01; 92(3):533-541. PubMed ID: 29105953 [Abstract] [Full Text] [Related]
7. Impact of Aortic Root Anatomy and Geometry on Paravalvular Leak in Transcatheter Aortic Valve Replacement With Extremely Large Annuli Using the Edwards SAPIEN 3 Valve. Tang GHL, Zaid S, George I, Khalique OK, Abramowitz Y, Maeno Y, Makkar RR, Jilaihawi H, Kamioka N, Thourani VH, Babaliaros V, Webb JG, Htun NM, Attinger-Toller A, Ahmad H, Kaple R, Sharma K, Kozina JA, Kaneko T, Shah P, Hirji SA, Desai ND, Anwaruddin S, Jagasia D, Herrmann HC, Basra SS, Szerlip MA, Mack MJ, Mathur M, Tan CW, Don CW, Sharma R, Gafoor S, Zhang M, Kapadia SR, Mick SL, Krishnaswamy A, Amoroso N, Salemi A, Wong SC, Kini AS, Rodés-Cabau J, Leon MB, Kodali SK. JACC Cardiovasc Interv; 2018 Jul 23; 11(14):1377-1387. PubMed ID: 29960755 [Abstract] [Full Text] [Related]
8. Impact of aortic valve calcification severity on device success after transcatheter aortic valve replacement. Larroche J, Panh L, Lhermusier T, Bataille V, Marachet MA, Chollet T, Petermann A, Bouisset F, Boudou N, Marcheix B, Rousseau H, Galinier M, Carrié D, Lairez O, Lavie-Badie Y. Int J Cardiovasc Imaging; 2020 Apr 23; 36(4):731-740. PubMed ID: 31916068 [Abstract] [Full Text] [Related]
9. Anatomical risk models for paravalvular leak and landing zone complications for balloon-expandable transcatheter aortic valve replacement. Condado JF, Corrigan FE, Lerakis S, Parastatidis I, Stillman AE, Binongo JN, Stewart J, Mavromatis K, Devireddy C, Leshnower B, Guyton R, Forcillo J, Patel A, Thourani VH, Block PC, Babaliaros V. Catheter Cardiovasc Interv; 2017 Oct 01; 90(4):690-700. PubMed ID: 28471092 [Abstract] [Full Text] [Related]
10. Aortic valve and left ventricular outflow tract calcium volume and distribution in transcatheter aortic valve replacement: Influence on the risk of significant paravalvular regurgitation. Hansson NC, Leipsic J, Pugliese F, Andersen HR, Rossi A, Simonato M, Jensen KT, Christiansen EH, Terkelsen CJ, Blanke P, Tang M, Krusell LR, Klaaborg KE, Terp K, Kennon S, Dvir D, Bøtker HE, Webb J, Nørgaard BL. J Cardiovasc Comput Tomogr; 2018 Oct 01; 12(4):290-297. PubMed ID: 29519754 [Abstract] [Full Text] [Related]
11. Predictors for Paravalvular Regurgitation After TAVR With the Self-Expanding Prosthesis: Quantitative Measurement of MDCT Analysis. Yoon SH, Ahn JM, Ohno Y, Barbanti M, Chan J, Lin MS, Kim YH, Yang DH, Sugiyama D, Chan KT, Immé S, Tamburino CI, Sgroi C, Park DW, Kang SJ, Lee SW, Lee CW, Park SW, Lee M, Kao HL, Tamburino C, Park SJ. JACC Cardiovasc Imaging; 2016 Oct 01; 9(10):1233-1234. PubMed ID: 26777220 [No Abstract] [Full Text] [Related]
12. Impact of device-host interaction on paravalvular aortic regurgitation with different transcatheter heart valves. Rodríguez-Olivares R, El Faquir N, Rahhab Z, van Gils L, Ren B, Sakhi R, Geleijnse ML, van Domburg R, de Jaegere PPT, Zamorano Gómez JL, Van Mieghem NM. Cardiovasc Revasc Med; 2019 Feb 01; 20(2):126-132. PubMed ID: 29779973 [Abstract] [Full Text] [Related]
13. Impact of device landing zone calcification patterns on paravalvular regurgitation after transcatheter aortic valve replacement with different next-generation devices. Mauri V, Frohn T, Deuschl F, Mohemed K, Kuhr K, Reimann A, Körber MI, Schofer N, Adam M, Friedrichs K, Kuhn EW, Scholtz S, Rudolph V, Wahlers TCW, Baldus S, Mader N, Schäfer U, Rudolph TK. Open Heart; 2020 May 01; 7(1):. PubMed ID: 32393655 [Abstract] [Full Text] [Related]
14. Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure. Barbanti M, Webb JG, Tamburino C, Van Mieghem NM, Makkar RR, Piazza N, Latib A, Sinning JM, Won-Keun K, Bleiziffer S, Bedogni F, Kapadia S, Tchetche D, Rodés-Cabau J, Fiorina C, Nombela-Franco L, De Marco F, de Jaegere PP, Chakravarty T, Vaquerizo B, Colombo A, Svensson L, Lange R, Nickenig G, Möllmann H, Walther T, Della Rosa F, Elhmidi Y, Dvir D, Brambilla N, Immè S, Sgroi C, Gulino S, Todaro D, Pilato G, Petronio AS, Tamburino C. Circ Cardiovasc Interv; 2016 Sep 01; 9(9):. PubMed ID: 27578840 [Abstract] [Full Text] [Related]
15. Computed Tomography-Based Oversizing Degrees and Incidence of Paravalvular Regurgitation of a New Generation Transcatheter Heart Valve. Blanke P, Pibarot P, Hahn R, Weissman N, Kodali S, Thourani V, Parvataneni R, Dvir D, Naoum C, Nørgaard BL, Douglas P, Jaber W, Khalique OK, Jilaihawi H, Mack M, Smith C, Leon M, Webb J, Leipsic J. JACC Cardiovasc Interv; 2017 Apr 24; 10(8):810-820. PubMed ID: 28427598 [Abstract] [Full Text] [Related]
16. 3D printing based on cardiac CT assists anatomic visualization prior to transcatheter aortic valve replacement. Ripley B, Kelil T, Cheezum MK, Goncalves A, Di Carli MF, Rybicki FJ, Steigner M, Mitsouras D, Blankstein R. J Cardiovasc Comput Tomogr; 2016 Apr 24; 10(1):28-36. PubMed ID: 26732862 [Abstract] [Full Text] [Related]
17. Optimal positioning of self-expanding valves before deployment decreases paravalvular regurgitation following transcatheter aortic valve replacement. Dadu RT, Xu J, Rehman H, von Ballmoos MW, Barker CM, Reyes M, Ramchandani M, Reul RM, Reardon MJ, Kleiman NS. Catheter Cardiovasc Interv; 2019 Jan 01; 93(1):149-155. PubMed ID: 30218488 [Abstract] [Full Text] [Related]
18. Potential impact of dynamic automated CT aortic annular measurements on outcomes for transcatheter aortic valve replacement sizing. Subramanyam P, Legasto AC, Al'Aref SJ, Wong SC, Truong QA. Int J Cardiovasc Imaging; 2020 Nov 01; 36(11):2291-2297. PubMed ID: 32621038 [Abstract] [Full Text] [Related]
19. Realistic Vascular Replicator for TAVR Procedures. Rotman OM, Kovarovic B, Sadasivan C, Gruberg L, Lieber BB, Bluestein D. Cardiovasc Eng Technol; 2018 Sep 01; 9(3):339-350. PubMed ID: 29654509 [Abstract] [Full Text] [Related]
20. Hemodynamic classification of paravalvular leakage after transcatheter aortic valve implantation compared with angiographic or echocardiographic classification for prediction of 1-year mortality. Schoechlin S, Brennemann T, Allali A, Ruile P, Jander N, Allgeier M, Gick M, Richardt G, Neumann FJ, Abdel-Wahab M. Catheter Cardiovasc Interv; 2018 May 01; 91(6):E56-E63. PubMed ID: 29105984 [Abstract] [Full Text] [Related] Page: [Next] [New Search]