These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


185 related items for PubMed ID: 320853

  • 41. [Emergent Re-do Mitral Valve Replacement for Prosthetic Valve Endocarditis with Increasing Obstruction of Mitral Valve].
    Paku M, Takeda T, Kohno S.
    Kyobu Geka; 2018 Dec; 71(13):1084-1087. PubMed ID: 30587747
    [Abstract] [Full Text] [Related]

  • 42. Cardiac pathology after valve replacement with a tilting disc prosthesis (Björk-Shiley type). A study of 46 necropsy patients and 49 Björk-Shiley prostheses.
    Roberts WC, Hammer WJ.
    Am J Cardiol; 1976 Jun; 37(7):1024-33. PubMed ID: 1274863
    [No Abstract] [Full Text] [Related]

  • 43.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 44.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 45.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 46. Postoperative disc entrapment following cardiac valve replacement--a report of ten cases.
    Järvinen A, Virtanen K, Peltola K, Maamies T, Ketonen P, Männikkö A.
    Thorac Cardiovasc Surg; 1984 Jun; 32(3):152-6. PubMed ID: 6206594
    [Abstract] [Full Text] [Related]

  • 47. [Echocardiographic diagnosis of malfunction of the Björk-Shiley prosthetic heart valve in the mitral position (author's transl)].
    Wisskirchen K, Mattern H, Fricke G.
    Z Kardiol; 1979 Jan; 68(1):21-5. PubMed ID: 419805
    [Abstract] [Full Text] [Related]

  • 48. [Massive mitral valve insufficiency caused by thrombosis in a Björk-Shiley prosthesis. Report of a case].
    Steyer de Munguía I, Hurtado del Río D, Carrillo López H, Gutiérrez Bosque R.
    Arch Inst Cardiol Mex; 1980 Jan; 50(2):157-60. PubMed ID: 7416863
    [Abstract] [Full Text] [Related]

  • 49. [Clinical experience in 3 cases, 5 events of thrombosed Björk-Shiley mitral prostheses].
    Kuwaki K, Matsuzaki T, Ichinomiya Y, Harada H, Ueda M, Komatsu S.
    Kyobu Geka; 1993 Jun; 46(6):498-502. PubMed ID: 8315921
    [Abstract] [Full Text] [Related]

  • 50.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 51. Repeated mitral valve replacement in the growing child with congenital mitral valve disease.
    Nudelman I, Schachner A, Levy MJ.
    J Thorac Cardiovasc Surg; 1980 May; 79(5):765-9. PubMed ID: 7366244
    [Abstract] [Full Text] [Related]

  • 52. Endocarditis on a Björk-Shiley mitral prosthesis due to Neisseria meningitidis.
    Dennis J, Edwards LD, Fisher TN, Makeever L.
    Scand J Thorac Cardiovasc Surg; 1977 May; 11(3):205-9. PubMed ID: 413188
    [Abstract] [Full Text] [Related]

  • 53. Perivalvular leakage 25 years after initial mitral valve replacement with a Björk-Shiley prosthesis.
    Minami H, Asada T, Gan K.
    Gen Thorac Cardiovasc Surg; 2008 Sep; 56(9):462-4. PubMed ID: 18791673
    [Abstract] [Full Text] [Related]

  • 54. Strut fracture and disc embolization in Björk-Shiley mitral valve prostheses: diagnosis and management.
    Davis PK, Myers JL, Pennock JL, Thiele BL.
    Ann Thorac Surg; 1985 Jul; 40(1):65-8. PubMed ID: 4015246
    [Abstract] [Full Text] [Related]

  • 55. [A case of acute extrinsic malfunction of prosthetic valve due to suture tag causing incomplete closure of the disc].
    Miyahara K, Kawase M, Sakakibara T, Ida T, Mannoji E, Hayashi K, Amano T, Shibuya M.
    Kyobu Geka; 1992 Jul; 45(7):635-9. PubMed ID: 1619830
    [Abstract] [Full Text] [Related]

  • 56. Mitral valve replacement with the Hancock, Björk-Shiley and Lillehei-Kaster prostheses. A comparison based on a 15-year follow-up.
    Milano A, Bortolotti U, Mazzucco A, Guerra F, Magni A, Stellin G, Gallucci V.
    Eur J Cardiothorac Surg; 1989 Jul; 3(4):312-9; discussion 319-20. PubMed ID: 2624803
    [Abstract] [Full Text] [Related]

  • 57. Aortic valve replacement with the Hancock standard, Björk-Shiley, and Lillehei-Kaster prostheses. A comparison based on follow-up from 1 to 15 years.
    Milano AD, Bortolotti U, Mazzucco A, Guerra F, Magni A, Gallucci V.
    J Thorac Cardiovasc Surg; 1989 Jul; 98(1):37-47. PubMed ID: 2739424
    [Abstract] [Full Text] [Related]

  • 58. [The contribution of echocardiography in the diagnosis of thrombosis of the Björk-Shiley valve in the mitral position (author's transl)].
    Giard A, Watel A, Delmon A, Pauchant M, Soots G.
    Ann Cardiol Angeiol (Paris); 1979 Jul; 28(2):119-23. PubMed ID: 453767
    [No Abstract] [Full Text] [Related]

  • 59. Sound spectral analysis of prosthetic valvular clicks for diagnosis of thrombosed Björk-Shiley tilting standard disc valve prostheses.
    Sato N, Miura M, Itoh T, Ohmi M, Haneda K, Mohri H, Nitta S, Tanaka M.
    J Thorac Cardiovasc Surg; 1993 Feb; 105(2):313-20. PubMed ID: 8429660
    [Abstract] [Full Text] [Related]

  • 60. A 22-year course of the Kay-Shiley disc valve with muscle guard at the mitral position.
    Sakamoto Y, Kurosawa H, Takakura H, Saitoh F, Naganuma H.
    Jpn J Thorac Cardiovasc Surg; 1999 Nov; 47(11):574-6. PubMed ID: 10614100
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 10.