These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
239 related items for PubMed ID: 32113456
1. Vacuum-compatible photon-counting hybrid pixel detector for wide-angle x-ray scattering, x-ray diffraction, and x-ray reflectometry in the tender x-ray range. Skroblin D, Schavkan A, Pflüger M, Pilet N, Lüthi B, Krumrey M. Rev Sci Instrum; 2020 Feb 01; 91(2):023102. PubMed ID: 32113456 [Abstract] [Full Text] [Related]
6. Using an in-vacuum CCD detector for simultaneous small- and wide-angle scattering at beamline X9. Yang L. J Synchrotron Radiat; 2013 Mar 10; 20(Pt 2):211-8. PubMed ID: 23412476 [Abstract] [Full Text] [Related]
7. Performance of small- and wide-angle x-ray scattering beamline at Indus-2 synchrotron. Das A, Bahadur J, Kumar A, Sen D. Rev Sci Instrum; 2023 Apr 01; 94(4):. PubMed ID: 38081274 [Abstract] [Full Text] [Related]
8. Implementation of a beam deflection system for studies of liquid interfaces on beamline I07 at Diamond. Arnold T, Nicklin C, Rawle J, Sutter J, Bates T, Nutter B, McIntyre G, Burt M. J Synchrotron Radiat; 2012 May 01; 19(Pt 3):408-16. PubMed ID: 22514177 [Abstract] [Full Text] [Related]
9. Components for the X-ray radiometry beamline at BESSY II. Krumrey M, Herrmann C, Müller P, Ulm G. J Synchrotron Radiat; 1998 May 01; 5(Pt 3):788-90. PubMed ID: 15263654 [Abstract] [Full Text] [Related]
10. Design of a four-crystal monochromator beamline for radiometry at BESSY II. Krumrey M. J Synchrotron Radiat; 1998 Jan 01; 5(Pt 1):6-9. PubMed ID: 16687794 [Abstract] [Full Text] [Related]
11. Highly versatile laboratory X-ray scattering instrument enabling (nano-)material structure analysis on multiple length scales by covering a scattering vector range of almost five decades. Bolze J, Gateshki M. Rev Sci Instrum; 2019 Dec 01; 90(12):123103. PubMed ID: 31893848 [Abstract] [Full Text] [Related]
18. Application of a pnCCD in X-ray diffraction: a three-dimensional X-ray detector. Leitenberger W, Hartmann R, Pietsch U, Andritschke R, Starke I, Strüder L. J Synchrotron Radiat; 2008 Sep 01; 15(Pt 5):449-57. PubMed ID: 18728315 [Abstract] [Full Text] [Related]
19. High-efficiency B₄C/Mo₂C alternate multilayer grating for monochromators in the photon energy range from 0.7 to 3.4 keV. Choueikani F, Lagarde B, Delmotte F, Krumrey M, Bridou F, Thomasset M, Meltchakov E, Polack F. Opt Lett; 2014 Apr 01; 39(7):2141-4. PubMed ID: 24686695 [Abstract] [Full Text] [Related]
20. Biomolecular solution X-ray scattering at the National Synchrotron Light Source. Allaire M, Yang L. J Synchrotron Radiat; 2011 Jan 01; 18(1):41-4. PubMed ID: 21169689 [Abstract] [Full Text] [Related] Page: [Next] [New Search]