These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
114 related items for PubMed ID: 32472279
1. The role of sagittal alignment in predicting major failure of lumbopelvic instrumentation: a biomechanical validation of lumbopelvic failure classification. Cho W, Wang W, Bucklen B. Spine Deform; 2020 Aug; 8(4):561-568. PubMed ID: 32472279 [Abstract] [Full Text] [Related]
2. The Role of Biological Fusion and Anterior Column Support in a Long Lumbopelvic Spinal Fixation and Its Effect on the S1 Screw-An In Silico Biomechanics Analysis. Cho W, Wang W, Bucklen B, Ramos RG, Yassari R. Spine (Phila Pa 1976); 2021 Feb 15; 46(4):E250-E256. PubMed ID: 33156284 [Abstract] [Full Text] [Related]
3. Failure of lumbopelvic fixation after long construct fusions in patients with adult spinal deformity: clinical and radiographic risk factors: clinical article. Cho W, Mason JR, Smith JS, Shimer AL, Wilson AS, Shaffrey CI, Shen FH, Novicoff WM, Fu KM, Heller JE, Arlet V. J Neurosurg Spine; 2013 Oct 15; 19(4):445-53. PubMed ID: 23909551 [Abstract] [Full Text] [Related]
4. Biomechanical effect of 4-rod technique on lumbosacral fixation: an in vitro human cadaveric investigation. Wang T, Liu H, Zheng Z, Li Z, Wang J, Shrivastava SS, Yang H. Spine (Phila Pa 1976); 2013 Jul 01; 38(15):E925-9. PubMed ID: 23609200 [Abstract] [Full Text] [Related]
5. Measurements of lumbopelvic lordosis using the pelvic radius technique as it correlates with sagittal spinal balance and sacral translation. Gardocki RJ, Watkins RG, Williams LA. Spine J; 2002 Jul 01; 2(6):421-9. PubMed ID: 14589266 [Abstract] [Full Text] [Related]
6. Congruent spinopelvic alignment on standing lateral radiographs of adult volunteers. Jackson RP, Hales C. Spine (Phila Pa 1976); 2000 Nov 01; 25(21):2808-15. PubMed ID: 11064527 [Abstract] [Full Text] [Related]
18. Rigid, semirigid versus dynamic instrumentation for degenerative lumbar spinal stenosis: a correlative radiological and clinical analysis of short-term results. Korovessis P, Papazisis Z, Koureas G, Lambiris E. Spine (Phila Pa 1976); 2004 Apr 01; 29(7):735-42. PubMed ID: 15087795 [Abstract] [Full Text] [Related]
19. Biomechanical comparison of iliac screws versus interbody femoral ring allograft on lumbosacral kinematics and sacral screw strain. Cunningham BW, Sefter JC, Hu N, Kim SW, Bridwell KH, McAfee PC. Spine (Phila Pa 1976); 2010 Mar 15; 35(6):E198-205. PubMed ID: 20195199 [Abstract] [Full Text] [Related]