These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
255 related items for PubMed ID: 32746104
21. Rotation Elastogram Estimation Using Synthetic Transmit-aperture Technique: A Feasibility Study. B L, Chintada BR, Thittai AK. Ultrason Imaging; 2017 May; 39(3):189-204. PubMed ID: 28091280 [Abstract] [Full Text] [Related]
22. Multi-source and multi-directional shear wave generation with intersecting steered ultrasound push beams. Nabavizadeh A, Song P, Chen S, Greenleaf JF, Urban MW. IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Apr; 62(4):647-62. PubMed ID: 25881343 [Abstract] [Full Text] [Related]
23. Supersonic transient magnetic resonance elastography for quantitative assessment of tissue elasticity. Liu Y, Liu J, Fite BZ, Foiret J, Ilovitsh A, Leach JK, Dumont E, Caskey CF, Ferrara KW. Phys Med Biol; 2017 May 21; 62(10):4083-4106. PubMed ID: 28426437 [Abstract] [Full Text] [Related]
24. Understanding the Contrast Mechanism in Rotation Elastogram: A Parametric Study. Lokesh B, Ten Dam AM, de Korte CL, Thittai AK. Ultrasound Med Biol; 2018 Aug 21; 44(8):1860-1872. PubMed ID: 29801975 [Abstract] [Full Text] [Related]
25. An octahedral shear strain-based measure of SNR for 3D MR elastography. McGarry MD, Van Houten EE, Perriñez PR, Pattison AJ, Weaver JB, Paulsen KD. Phys Med Biol; 2011 Jul 07; 56(13):N153-64. PubMed ID: 21654044 [Abstract] [Full Text] [Related]
26. Comb-push ultrasound shear elastography (CUSE) with various ultrasound push beams. Song P, Urban MW, Manduca A, Zhao H, Greenleaf JF, Chen S. IEEE Trans Med Imaging; 2013 Aug 07; 32(8):1435-47. PubMed ID: 23591479 [Abstract] [Full Text] [Related]
28. Method to estimate the deviation from ideal uniaxial compression during freehand elastography. Xia R, Thittai AK. Ultrason Imaging; 2015 Jan 07; 37(1):70-82. PubMed ID: 24916397 [Abstract] [Full Text] [Related]
29. Single tracking location methods suppress speckle noise in shear wave velocity estimation. Elegbe EC, McAleavey SA. Ultrason Imaging; 2013 Apr 07; 35(2):109-25. PubMed ID: 23493611 [Abstract] [Full Text] [Related]
30. Dynamic frame pairing in real-time freehand elastography. Xia R, Tao G, Thittai AK. IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Jun 07; 61(6):979-85. PubMed ID: 24859661 [Abstract] [Full Text] [Related]
31. Detection of gaps between high-intensity focused ultrasound (HIFU)-induced lesions using transient axial shear strain elastograms. Liu C, Zhou Y. Med Phys; 2018 Jul 02. PubMed ID: 29963699 [Abstract] [Full Text] [Related]
32. Comb-push ultrasound shear elastography (CUSE): a novel method for two-dimensional shear elasticity imaging of soft tissues. Song P, Zhao H, Manduca A, Urban MW, Greenleaf JF, Chen S. IEEE Trans Med Imaging; 2012 Sep 02; 31(9):1821-32. PubMed ID: 22736690 [Abstract] [Full Text] [Related]
33. Ex vivo bovine liver nonlinear viscoelastic properties: MR elastography and rheological measurements. Jugé L, Foley P, Hatt A, Yeung J, Bilston LE. J Mech Behav Biomed Mater; 2023 Feb 02; 138():105638. PubMed ID: 36623403 [Abstract] [Full Text] [Related]
34. Reverberant magnetic resonance elastographic imaging using a single mechanical driver. Kabir IE, Caban-Rivera DA, Ormachea J, Parker KJ, Johnson CL, Doyley MM. Phys Med Biol; 2023 Feb 27; 68(5):. PubMed ID: 36780698 [Abstract] [Full Text] [Related]
35. Performance evaluation of different implementations of the Lagrangian speckle model estimator for non-invasive vascular ultrasound elastography. Mercure E, Cloutier G, Schmitt C, Maurice RL. Med Phys; 2008 Jul 27; 35(7):3116-26. PubMed ID: 18697537 [Abstract] [Full Text] [Related]
36. Hadamard-Encoded Synthetic Transmit Aperture Imaging for Improved Lateral Motion Estimation in Ultrasound Elastography. Wang Y, Xie X, He Q, Liao H, Zhang H, Luo J. IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Apr 27; 69(4):1204-1218. PubMed ID: 35100113 [Abstract] [Full Text] [Related]
37. 3D Global Time-Delay Estimation for Shear-Wave Absolute Vibro-Elastography of the Placenta. Hashemi HS, Honarvar M, Salcudean T, Rohling R. Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul 27; 2020():2079-2083. PubMed ID: 33018415 [Abstract] [Full Text] [Related]
38. Regularization-Based 2D Strain Tensor Imaging in Quasi-Static Ultrasound Elastography SAGE Publications. Duroy AL, Detti V, Coulon A, Basset O, Brusseau E. Ultrason Imaging; 2023 Jul 27; 45(4):187-205. PubMed ID: 37231671 [Abstract] [Full Text] [Related]
39. Shear wave pulse compression for dynamic elastography using phase-sensitive optical coherence tomography. Nguyen TM, Song S, Arnal B, Wong EY, Huang Z, Wang RK, O'Donnell M. J Biomed Opt; 2014 Jan 27; 19(1):16013. PubMed ID: 24441876 [Abstract] [Full Text] [Related]
40. Real-time monitoring of high-intensity focused ultrasound treatment using axial strain and axial-shear strain elastograms. Xia R, Thittai AK. Ultrasound Med Biol; 2014 Mar 27; 40(3):485-95. PubMed ID: 24361216 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]