These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


167 related items for PubMed ID: 3290261

  • 1. Titanium-coated hollow screw and reconstruction plate system (THORP) in mandibular reconstruction.
    Hellem S, Olofsson J.
    J Craniomaxillofac Surg; 1988 May; 16(4):173-83. PubMed ID: 3290261
    [Abstract] [Full Text] [Related]

  • 2. Mandibular reconstruction with the THORP condylar prosthesis after hemimandibulectomy.
    Vuillemin T, Raveh J, Sutter F.
    J Craniomaxillofac Surg; 1989 Feb; 17(2):78-87. PubMed ID: 2921333
    [Abstract] [Full Text] [Related]

  • 3. Mandibular reconstruction with the titanium hollow screw reconstruction plate (THORP) system: evaluation of 62 cases.
    Vuillemin T, Raveh J, Sutter F.
    Plast Reconstr Surg; 1988 Nov; 82(5):804-14. PubMed ID: 3174870
    [Abstract] [Full Text] [Related]

  • 4. [Mandibular reconstruction with the titanium-hollow screw-reconstruction plate system (THORP)].
    Vuillemin T, Raveh J, Sutter F.
    Schweiz Monatsschr Zahnmed; 1990 Nov; 100(6):701-8. PubMed ID: 2377883
    [Abstract] [Full Text] [Related]

  • 5. Use of the titanium-coated hollow screw and reconstruction plate system in bridging of lower jaw defects.
    Raveh J, Stich H, Sutter F, Greiner R.
    J Oral Maxillofac Surg; 1984 May; 42(5):281-94. PubMed ID: 6371200
    [Abstract] [Full Text] [Related]

  • 6. [Bridging of the defect by the lingual approach and bone graft fixation in the mandible with the THRP (titanium-coated hollow-screw and reconstruction plate) system].
    Raveh J, Sutter F.
    Schweiz Monatsschr Zahnmed (1984); 1984 Feb; 94(2):134-42. PubMed ID: 6367030
    [No Abstract] [Full Text] [Related]

  • 7. Titanium-coated hollow screw and reconstruction plate system for bridging of lower jaw defects: biomechanical aspects.
    Sutter F, Raveh J.
    Int J Oral Maxillofac Surg; 1988 Aug; 17(4):267-74. PubMed ID: 3139801
    [Abstract] [Full Text] [Related]

  • 8. Advantages of mandibular reconstruction with the titanium hollow screw osseointegrating reconstruction plate (THORP).
    Koch WM, Yoo GH, Goodstein ML, Eisele DW, Richtsmeier WJ, Price JC.
    Laryngoscope; 1994 May; 104(5 Pt 1):545-52. PubMed ID: 8189984
    [Abstract] [Full Text] [Related]

  • 9. [Advantages of the titanium plasma-coated half- and full-core reconstruction plate system (THORP) for the bridging of mandibular defects].
    Raveh J, Vuillemin T, Lädrach K, Sutter F.
    Ther Umsch; 1987 Feb; 44(2):137-50. PubMed ID: 3576504
    [No Abstract] [Full Text] [Related]

  • 10. Rigid fixation of vascularized bone grafts in mandibular reconstruction.
    Futran ND, Urken ML, Buchbinder D, Moscoso JF, Biller HF.
    Arch Otolaryngol Head Neck Surg; 1995 Jan; 121(1):70-6. PubMed ID: 7803025
    [Abstract] [Full Text] [Related]

  • 11. [Titanium-coated hollow screw and reconstruction plate system for the bridging of jaw defects. II. Possible reconstruction variants with the THRP system].
    Raveh J, Stich H, Sutter F.
    Chirurg; 1985 May; 56(5):337-44. PubMed ID: 3891246
    [Abstract] [Full Text] [Related]

  • 12. Comparative study of locking plates in mandibular reconstruction after ablative tumor surgery: THORP versus UniLOCK system.
    Gellrich NC, Suarez-Cunqueiro MM, Otero-Cepeda XL, Schön R, Schmelzeisen R, Gutwald R.
    J Oral Maxillofac Surg; 2004 Feb; 62(2):186-93. PubMed ID: 14762751
    [Abstract] [Full Text] [Related]

  • 13. Long-term stability of two different mandibular bridging systems.
    Söderholm AL, Hallikainen D, Lindqvist C.
    Arch Otolaryngol Head Neck Surg; 1993 Sep; 119(9):1031-6. PubMed ID: 8357585
    [Abstract] [Full Text] [Related]

  • 14.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 15. Improving the mandibular reconstruction plate: technical innovation.
    Gregory GF, Gavin DV.
    J R Coll Surg Edinb; 2000 Apr; 45(2):120-1. PubMed ID: 10822921
    [Abstract] [Full Text] [Related]

  • 16. AO reconstruction plate systems for the repair of mandibular defects 3-DBRP versus Thorp-system.
    Stoll P, Wächter R.
    J Craniomaxillofac Surg; 1992 Jan; 20(1):40-5. PubMed ID: 1564120
    [Abstract] [Full Text] [Related]

  • 17. [Titanium plasma-coated hollow screws and reconstruction plate system for the bridging of jaw defects. I. Basic principles and biomechanical properties].
    Sutter F, Raveh J, Schürch H, Stich H.
    Chirurg; 1984 Nov; 55(11):741-8. PubMed ID: 6510088
    [No Abstract] [Full Text] [Related]

  • 18. Analysis of complications after reconstruction of bone defects involving complete mandibular resection using finite element modelling.
    Markwardt J, Pfeifer G, Eckelt U, Reitemeier B.
    Onkologie; 2007 Mar; 30(3):121-6. PubMed ID: 17341898
    [Abstract] [Full Text] [Related]

  • 19. New concepts in the reconstruction of mandibular defects following tumor resection.
    Raveh Y, Stich H, Sutter F, Greiner R.
    J Oral Maxillofac Surg; 1983 Jan; 41(1):3-16. PubMed ID: 6571737
    [Abstract] [Full Text] [Related]

  • 20. Fixation with reconstruction plates under critical conditions: the role of screw characteristics.
    Söderholm AL, Rahn BA, Skutnabb K, Lindqvist C.
    Int J Oral Maxillofac Surg; 1996 Dec; 25(6):469-73. PubMed ID: 8986552
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 9.