These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
218 related items for PubMed ID: 32989788
1. High-resolution multi-T1 -weighted contrast and T1 mapping with low B1>+ sensitivity using the fluid and white matter suppression (FLAWS) sequence at 7T. Beaumont J, Gambarota G, Saint-Jalmes H, Acosta O, Ferré JC, Raniga P, Fripp J. Magn Reson Med; 2021 Mar; 85(3):1364-1378. PubMed ID: 32989788 [Abstract] [Full Text] [Related]
2. Advantages of fluid and white matter suppression (FLAWS) with MP2RAGE compared with double inversion recovery turbo spin echo (DIR-TSE) at 7T. Urushibata Y, Kuribayashi H, Fujimoto K, Kober T, Grinstead JW, Isa T, Okada T. Eur J Radiol; 2019 Jul; 116():160-164. PubMed ID: 31153559 [Abstract] [Full Text] [Related]
3. Fluid and White Matter Suppression: New Sensitive 3 T Magnetic Resonance Imaging Contrasts for Cortical Lesion Detection in Multiple Sclerosis. Müller J, La Rosa F, Beaumont J, Tsagkas C, Rahmanzadeh R, Weigel M, Bach Cuadra M, Gambarota G, Granziera C. Invest Radiol; 2022 Sep 01; 57(9):592-600. PubMed ID: 35510874 [Abstract] [Full Text] [Related]
4. Simultaneous Optimization of MP2RAGE T1 -weighted (UNI) and FLuid And White matter Suppression (FLAWS) brain images at 7T using Extended Phase Graph (EPG) Simulations. Dokumacı AS, Aitken FR, Sedlacik J, Bridgen P, Tomi-Tricot R, Mooiweer R, Vecchiato K, Wilkinson T, Casella C, Giles S, Hajnal JV, Malik SJ, O'Muircheartaigh J, Carmichael DW. Magn Reson Med; 2023 Mar 01; 89(3):937-950. PubMed ID: 36352772 [Abstract] [Full Text] [Related]
5. Whole brain and deep gray matter structure segmentation: Quantitative comparison between MPRAGE and MP2RAGE sequences. Droby A, Thaler A, Giladi N, Hutchison RM, Mirelman A, Ben Bashat D, Artzi M. PLoS One; 2021 Mar 01; 16(8):e0254597. PubMed ID: 34358242 [Abstract] [Full Text] [Related]
6. Optimization and validation of low-field MP2RAGE T1 mapping on 0.35T MR-Linac: Toward adaptive dose painting with hypoxia biomarkers. Park CKS, Warner NS, Kaza E, Sudhyadhom A. Med Phys; 2024 Nov 01; 51(11):8124-8140. PubMed ID: 39140821 [Abstract] [Full Text] [Related]
7. Can 7T MPRAGE match MP2RAGE for gray-white matter contrast? Oliveira ÍAF, Roos T, Dumoulin SO, Siero JCW, van der Zwaag W. Neuroimage; 2021 Oct 15; 240():118384. PubMed ID: 34265419 [Abstract] [Full Text] [Related]
8. The impact of B1+ correction on MP2RAGE cortical T1 and apparent cortical thickness at 7T. Haast RAM, Ivanov D, Uludağ K. Hum Brain Mapp; 2018 Jun 15; 39(6):2412-2425. PubMed ID: 29457319 [Abstract] [Full Text] [Related]
12. STrategically Acquired Gradient Echo (STAGE) imaging, part I: Creating enhanced T1 contrast and standardized susceptibility weighted imaging and quantitative susceptibility mapping. Chen Y, Liu S, Wang Y, Kang Y, Haacke EM. Magn Reson Imaging; 2018 Feb 15; 46():130-139. PubMed ID: 29056394 [Abstract] [Full Text] [Related]
13. Radiofrequency Bias Correction of Magnetization Prepared Rapid Gradient Echo MRI at 7.0 Tesla Using an External Reference in a Sequential Protocol. Olsson H, Novén M, Lätt J, Wirestam R, Helms G. Tomography; 2021 Sep 13; 7(3):434-451. PubMed ID: 34564300 [Abstract] [Full Text] [Related]
17. An Ultra-High Field Study of Cerebellar Pathology in Early Relapsing-Remitting Multiple Sclerosis Using MP2RAGE. Fartaria MJ, OʼBrien K, Şorega A, Bonnier G, Roche A, Falkovskiy P, Krueger G, Kober T, Bach Cuadra M, Granziera C. Invest Radiol; 2017 May 13; 52(5):265-273. PubMed ID: 27898603 [Abstract] [Full Text] [Related]
18. 7T MPFLAIR versus MP2RAGE for Quantifying Lesion Volume in Multiple Sclerosis. Spini M, Choi S, Harrison DM. J Neuroimaging; 2020 Jul 13; 30(4):531-536. PubMed ID: 32569408 [Abstract] [Full Text] [Related]