These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Improved reconstruction stability for chemical shift encoded hyperpolarized 13 C magnetic resonance spectroscopic imaging using k-t spiral acquisitions. Macdonald EB, Barton GP, Cox BL, Johnson KM, Strigel RM, Fain SB. Magn Reson Med; 2020 Jul; 84(1):25-38. PubMed ID: 31814173 [Abstract] [Full Text] [Related]
6. Technique development of 3D dynamic CS-EPSI for hyperpolarized 13 C pyruvate MR molecular imaging of human prostate cancer. Chen HY, Larson PEZ, Gordon JW, Bok RA, Ferrone M, van Criekinge M, Carvajal L, Cao P, Pauly JM, Kerr AB, Park I, Slater JB, Nelson SJ, Munster PN, Aggarwal R, Kurhanewicz J, Vigneron DB. Magn Reson Med; 2018 Nov; 80(5):2062-2072. PubMed ID: 29575178 [Abstract] [Full Text] [Related]
8. Comparison of selective excitation and multi-echo chemical shift encoding for imaging of hyperpolarized [1-13C]pyruvate. Michel KA, Ragavan M, Walker CM, Merritt ME, Lai SY, Bankson JA. J Magn Reson; 2021 Apr; 325():106927. PubMed ID: 33607386 [Abstract] [Full Text] [Related]
9. Combining multiband slice selection with consistent k-t-space EPSI for accelerated spectral imaging. Schmidt R, Seginer A, Tal A. Magn Reson Med; 2019 Sep; 82(3):867-876. PubMed ID: 30990227 [Abstract] [Full Text] [Related]
10. Frequency correction method for improved spatial correlation of hyperpolarized 13C metabolites and anatomy. Cunningham CH, Dominguez Viqueira W, Hurd RE, Chen AP. NMR Biomed; 2014 Feb; 27(2):212-8. PubMed ID: 24353129 [Abstract] [Full Text] [Related]
12. In vivo single-shot 13C spectroscopic imaging of hyperpolarized metabolites by spatiotemporal encoding. Schmidt R, Laustsen C, Dumez JN, Kettunen MI, Serrao EM, Marco-Rius I, Brindle KM, Ardenkjaer-Larsen JH, Frydman L. J Magn Reson; 2014 Mar; 240():8-15. PubMed ID: 24486720 [Abstract] [Full Text] [Related]
13. Overdiscrete echo-planar spectroscopic imaging with correlated higher-order phase correction. Coello E, Hafalir FS, Noeske R, Menzel M, Haase A, Menze B, Schulte RF. Magn Reson Med; 2020 Jul; 84(1):11-24. PubMed ID: 31828853 [Abstract] [Full Text] [Related]
14. Reduction of spectral ghost artifacts in high-resolution echo-planar spectroscopic imaging of water and fat resonances. Du W, Du YP, Fan X, Zamora MA, Karczmar GS. Magn Reson Med; 2003 Jun; 49(6):1113-20. PubMed ID: 12768590 [Abstract] [Full Text] [Related]
20. Artifact suppression in readout-segmented consistent K-t space EPSI (RS-COKE) for fast 1 H spectroscopic imaging at 7 T. Seginer A, Keith GA, Porter DA, Schmidt R. Magn Reson Med; 2022 Dec; 88(6):2339-2357. PubMed ID: 35975965 [Abstract] [Full Text] [Related] Page: [Next] [New Search]