143 related items for PubMed ID: 33303712

  • 1. Evaluation of the Barricor Tube in 28 Routine Chemical Tests and Its Impact on Turnaround Time in an Outpatient Clinic.
    Moon SY, Lee HS, Park MS, Kim IS, Lee SM.
    Ann Lab Med; 2021 May 01; 41(3):277-284. PubMed ID: 33303712
    [Abstract] [Full Text] [Related]

  • 2. Improved Sample Quality and Decreased Turnaround Time When Using Plasma Blood Collection Tubes with a Mechanical Separator in a Large University Hospital.
    Hétu PO, Hobeila S, Larivière F, Bélanger MC.
    J Appl Lab Med; 2021 Mar 01; 6(2):409-420. PubMed ID: 32989467
    [Abstract] [Full Text] [Related]

  • 3. Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube.
    Shin S, Oh J, Park HD.
    Ann Lab Med; 2021 Jan 01; 41(1):114-119. PubMed ID: 32829587
    [Abstract] [Full Text] [Related]

  • 4. Test results comparison and sample stability study: is the BD Barricor tube a suitable replacement for the BD RST tube?
    Mandić S, Mandić D, Lukić I, Rolić T, Horvat V, Lukić M, Osvald S, Šerić V.
    Biochem Med (Zagreb); 2020 Oct 15; 30(3):030704. PubMed ID: 33071555
    [Abstract] [Full Text] [Related]

  • 5. Barricor blood collection tubes are equivalent to PST for a variety of chemistry and immunoassay analytes except for lactate dehydrogenase.
    Raizman JE, Goudreau BL, Füzéry AK, Cembrowski GS.
    Clin Chim Acta; 2019 Sep 15; 496():18-24. PubMed ID: 31201816
    [Abstract] [Full Text] [Related]

  • 6. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube.
    Arslan FD, Karakoyun I, Basok BI, Aksit MZ, Baysoy A, Ozturk YK, Guclu YA, Duman C.
    Biochem Med (Zagreb); 2017 Oct 15; 27(3):030706. PubMed ID: 28900369
    [Abstract] [Full Text] [Related]

  • 7. Evaluation of the BD Vacutainer(®) RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study.
    Kocijancic M, Cargonja J, Delic-Knezevic A.
    Biochem Med (Zagreb); 2014 Oct 15; 24(3):368-75. PubMed ID: 25351355
    [Abstract] [Full Text] [Related]

  • 8. The BD Barricor blood collection tube is an acceptable and robust alternative to the PST for use with the Beckman AccuTnI+3 assay.
    Füzéry AK, Raizman JE, Goudreau BL, Moses K, Niemann K, Park J, Cembrowski GS.
    Clin Biochem; 2017 Oct 15; 50(15):851-857. PubMed ID: 28583435
    [Abstract] [Full Text] [Related]

  • 9. Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes.
    Cadamuro J, Mrazek C, Leichtle AB, Kipman U, Felder TK, Wiedemann H, Oberkofler H, Fiedler GM, Haschke-Becher E.
    Biochem Med (Zagreb); 2018 Feb 15; 28(1):010704. PubMed ID: 29187797
    [Abstract] [Full Text] [Related]

  • 10. A Multicenter Evaluation of a Nongel Mechanical Separator Plasma Blood Collection Tube for Testing of Selected Therapeutic Drugs.
    Morosyuk S, Berube J, Christenson R, Wu AHB, Uettwiller-Geiger D, Palicka V, Prusa R, Zima T, Shaw K, Plokhoy E, Ahuja AJ, Stankovic AK.
    J Appl Lab Med; 2020 Jul 01; 5(4):671-685. PubMed ID: 32603441
    [Abstract] [Full Text] [Related]

  • 11. Improved quality of samples and laboratory turnaround time using 3.5 mL low vacuum BD Vacutainer® Barricor tubes in the emergency department.
    Badiou S, Vuillot O, Bargnoux AS, Kuster N, Lefebvre S, Sebbane M, Cristol JP, Dupuy AM.
    Pract Lab Med; 2019 Aug 01; 16():e00128. PubMed ID: 31289734
    [Abstract] [Full Text] [Related]

  • 12. A comparison of stability of chemical analytes in plasma from the BD Vacutainer® Barricor™ tube with mechanical separator versus tubes containing gel separator.
    Gawria G, Tillmar L, Landberg E.
    J Clin Lab Anal; 2020 Feb 01; 34(2):e23060. PubMed ID: 31605419
    [Abstract] [Full Text] [Related]

  • 13. Biochemical, immunochemical and serology analytes validation of the lithium heparin BD Barricor blood collection tube on a highly automated Roche COBAS8000 instrument.
    Ferrari D, Strollo M, Vidali M, Motta A, Pontillo M, Locatelli M.
    Acta Biomed; 2020 Mar 19; 91(1):47-55. PubMed ID: 32191654
    [Abstract] [Full Text] [Related]

  • 14. Quality of plasma samples and BD Vacutainer Barricor tubes: Effects of centrifugation.
    Padoan A, Zaninotto M, Piva E, Sciacovelli L, Aita A, Tasinato A, Plebani M.
    Clin Chim Acta; 2018 Aug 19; 483():271-274. PubMed ID: 29753681
    [Abstract] [Full Text] [Related]

  • 15. Stability of potassium, calcium and phosphorus electrolytes in three different tubes in patients with essential thrombocytosis.
    Aksit M, Zeytinli Aksit M, Colak A, Isbilen Basok B, Ceylan C.
    Scand J Clin Lab Invest; 2023 Dec 19; 83(8):582-590. PubMed ID: 38063345
    [Abstract] [Full Text] [Related]

  • 16. Switching from serum to plasma: Implementation of BD Vacutainer® Barricor™ Plasma Blood Collection Tubes improves sample quality and laboratory turnaround time.
    Ramakers C, Meyer B, Yang W, Plokhoy E, Xiong Y, Church S, Kaushik N.
    Pract Lab Med; 2020 Jan 19; 18():e00149. PubMed ID: 31909146
    [Abstract] [Full Text] [Related]

  • 17. Introduction of BD Vacutainer® Barricor™ tubes in clinical biobanking and application of amino acid and cytokine quality indicators to Barricor plasma.
    Knutti N, Neugebauer S, Scherr F, Mathay C, Marchese M, Henry E, Palm J, Betsou F, Kiehntopf M.
    Clin Chem Lab Med; 2022 Apr 26; 60(5):689-700. PubMed ID: 35073617
    [Abstract] [Full Text] [Related]

  • 18. Evaluation of BD Barricor™ Plasma Blood Collection Tube for Biochemical Tests.
    Kösem A, Topçuoğlu C, Sezer S, Cevher ŞK, Yenigün EC, Dede F, Turhan T.
    Clin Lab; 2019 Dec 01; 65(12):. PubMed ID: 31850716
    [Abstract] [Full Text] [Related]

  • 19. Validation of Becton Dickinson Barricor tubes for use with Abbott Alinity and Siemens Atellica® highly sensitive cardiac troponin I measuring systems.
    Gajewski P, Krintus M, Chudas K, Pawlowski R, Laskowska E, Jasiewicz M, Szternel L, El-Essa A, Kubica J, Sypniewska G, Panteghini M.
    EJIFCC; 2024 Apr 01; 35(1):10-22. PubMed ID: 38706733
    [Abstract] [Full Text] [Related]

  • 20. Evaluation of the quick-clotting serum separator tube, VQ-Tube™, for clinical chemistry and thyroid hormone assays.
    Jo SJ, Chae H, Lee YW, Seo JD, Song SH, Lee J.
    Ann Clin Biochem; 2021 Sep 01; 58(5):468-473. PubMed ID: 33940935
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]