These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


162 related items for PubMed ID: 3336227

  • 1. A new method for separate lung ventilation.
    Nazari S, Trazzi R, Moncalvo F, Carahella F, Bellinzona G, Braschi A, Scaroni MT, Mapelli A.
    J Thorac Cardiovasc Surg; 1988 Jan; 95(1):133-8. PubMed ID: 3336227
    [Abstract] [Full Text] [Related]

  • 2. Selective bronchial intubation for one lung anaesthesia in thoracic surgery. A new method.
    Nazari S, Trazzi R, Moncalvo F, Zonta A, Campani M.
    Anaesthesia; 1986 May; 41(5):519-26. PubMed ID: 3728911
    [Abstract] [Full Text] [Related]

  • 3. [Selective right bronchial intubation using tracheal tubes under fibroscopic guidance].
    Correa J, Litvan H, Casas JI, Moreno M, Villar-Landeira JM.
    Rev Esp Anestesiol Reanim; 1992 May; 39(2):113-6. PubMed ID: 1594778
    [Abstract] [Full Text] [Related]

  • 4. [A new single-lumen endobronchial tube for artificial respiration following pneumonectomy in thoracic surgery].
    Brendle BC, Morgan JA.
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1992 Feb; 27(1):53-5. PubMed ID: 1504192
    [Abstract] [Full Text] [Related]

  • 5. [Placement of a double-lumen tube using a 6 mm diameter fibro-bronchoscope and a Cook exchange catheter in a patient with unforeseen tracheal intubation difficulty].
    Villalonga A, Metje M, Torres-Bahí S, Aragonès N, Navarro M, March X.
    Rev Esp Anestesiol Reanim; 2002 Apr; 49(4):205-8. PubMed ID: 14606381
    [Abstract] [Full Text] [Related]

  • 6. [Thoracoscopic surgery using a new bronchial blocker].
    Okada S, Ishimori S, Yamagata S, Satoh S, Kato T, Yaegashi S.
    Kyobu Geka; 2004 Nov; 57(12):1113-6. PubMed ID: 15553027
    [Abstract] [Full Text] [Related]

  • 7. [Artificial lung ventilation using separate intubation of two main bronchi in patients with acute respiratory failure].
    Galstian GM, Shulutko EM, Riazanova IB, Iatskov KV, Makhinia VA, Togonidze DK.
    Anesteziol Reanimatol; 2005 Nov; (3):27-33. PubMed ID: 16076042
    [Abstract] [Full Text] [Related]

  • 8. [Separation of the airways: historical aspects].
    Wiedemann K, Fleischer E, Dressler P.
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2002 Jan; 37(1):8-15. PubMed ID: 11845374
    [Abstract] [Full Text] [Related]

  • 9. [Applications for bronchial blockers in thoracic surgery].
    García-Guasch R, Campos JH, Granell M, Peña JJ.
    Rev Esp Anestesiol Reanim; 2007 Nov; 54(9):547-55. PubMed ID: 18085108
    [Abstract] [Full Text] [Related]

  • 10. [Right bronchial intubation using a left-sided double-lumen tube in a patient with situs inversus].
    Bougaki M, Orii R, Yamada Y.
    Masui; 2007 Dec; 56(12):1411-3. PubMed ID: 18078097
    [Abstract] [Full Text] [Related]

  • 11. Bronchial blocker compared to double-lumen tube for one-lung ventilation during thoracoscopy.
    Bauer C, Winter C, Hentz JG, Ducrocq X, Steib A, Dupeyron JP.
    Acta Anaesthesiol Scand; 2001 Feb; 45(2):250-4. PubMed ID: 11167173
    [Abstract] [Full Text] [Related]

  • 12. New technique for one-lung anesthesia using an endobronchial blocker.
    Ginsberg RJ.
    J Thorac Cardiovasc Surg; 1981 Oct; 82(4):542-6. PubMed ID: 7278345
    [Abstract] [Full Text] [Related]

  • 13. High-frequency ventilation with an uncuffed endobronchial tube. A new technique for one-lung anesthesia.
    El-Baz NM, Kittle CF, Faber LP, Welsher W.
    J Thorac Cardiovasc Surg; 1982 Dec; 84(6):823-8. PubMed ID: 7144216
    [Abstract] [Full Text] [Related]

  • 14. [The proper size of bronchial tube for pediatric differential lung ventilation using laryngeal mask airway].
    Fujiwara S, Takemine K, Kakiuchi H, Tsujimoto S, Tashiro C.
    Masui; 2004 Feb; 53(2):137-42. PubMed ID: 15011420
    [Abstract] [Full Text] [Related]

  • 15. [Bronchial blocking with a balloon wedge pressure Catheter in a small infant].
    Satoi AH, Murao K, Kubo K, Takeyasu A, Ohashi A, Nakao S, Shingu K.
    Masui; 2006 Apr; 55(4):475-7. PubMed ID: 16634556
    [Abstract] [Full Text] [Related]

  • 16. [Differential lung ventilation using laryngeal mask airway and a bronchial blocker tube for a patient with unanticipated difficult intubation].
    Tsuchihashi T, Ide S, Nakagawa H, Hishinuma N, Takano T, Nishizawa M.
    Masui; 2007 Sep; 56(9):1075-7. PubMed ID: 17877050
    [Abstract] [Full Text] [Related]

  • 17. [Right main bronchus obstruction in a patient intubated with a left double-lumen tube for thoracic aortic surgery].
    Valdivia J, Ferrá M, Moyano P, Garrido P.
    Rev Esp Anestesiol Reanim; 2006 May; 53(5):315-8. PubMed ID: 16827072
    [Abstract] [Full Text] [Related]

  • 18. Failure to provide adequate one-lung ventilation with a conventional endotracheal tube using a transbronchial approach: a case report.
    Ng YT, Chung PC, Hsieh JR, Yu CC, Lau WM, Liu YH.
    Can J Anaesth; 2003 May; 50(6):603-6. PubMed ID: 12826555
    [Abstract] [Full Text] [Related]

  • 19. [One-lung ventilation using a new original connector: with a bronchial blocker and a single lumen tracheal tube].
    Ishizaki T, Yanagihara H, Isshiki A.
    Masui; 2003 Feb; 52(2):191-4. PubMed ID: 12649882
    [Abstract] [Full Text] [Related]

  • 20. One lung ventilation in infants and children: experience with Marraro double lumen tube.
    Pawar DK, Marraro GA.
    Paediatr Anaesth; 2005 Mar; 15(3):204-8. PubMed ID: 15725317
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 9.