These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
228 related items for PubMed ID: 33393649
41. The conventional versus automated measurement of blood pressure in the office (CAMBO) trial: masked hypertension sub-study. Myers MG, Godwin M, Dawes M, Kiss A, Tobe SW, Kaczorowski J. J Hypertens; 2012 Oct; 30(10):1937-41. PubMed ID: 22828087 [Abstract] [Full Text] [Related]
42. Smartphone Application-Assisted Home Blood Pressure Monitoring Compared With Office and Ambulatory Blood Pressure Monitoring in Patients With Hypertension: the AMUSE-BP Study. Groenland EH, Vendeville JAC, Bemelmans RHH, Monajemi H, Bots ML, Visseren FLJ, Spiering W. Hypertension; 2022 Oct; 79(10):2373-2382. PubMed ID: 35959685 [Abstract] [Full Text] [Related]
45. Usefulness of ambulatory blood pressure monitoring in chronic kidney disease: The moroccan experience. Asserraji M, Bouzerda A, Soukrate S, Maoujoud O, Belarbi M, Zemraoui N, Bendriss L, Khatouri A. Saudi J Kidney Dis Transpl; 2019 Oct; 30(4):913-918. PubMed ID: 31464249 [Abstract] [Full Text] [Related]
46. Automated office blood pressure measurements obtained with and without preceding rest are associated with awake ambulatory blood pressure. Andreadis EA, Geladari CV, Angelopoulos ET. J Clin Hypertens (Greenwich); 2020 Jan; 22(1):32-38. PubMed ID: 31786829 [Abstract] [Full Text] [Related]
48. Screening for hypertension: an elevated office blood pressure measurement is valuable, adding an automated one is even better. Michaud A, Lamarre-Cliche M, Cloutier L. Blood Press Monit; 2019 Jun; 24(3):123-129. PubMed ID: 30998552 [Abstract] [Full Text] [Related]
49. Comparison between unattended automated office blood pressure and conventional office blood pressure under the environment of health checkup among Japanese general population. Sakuma H, Nakagawa N, Horiuchi K, Hayasaka T, Maruyama K, Sawada J, Minoshima A, Fujino T, Takeuchi T, Sato N, Osanai S, Hasebe N. J Clin Hypertens (Greenwich); 2020 Oct; 22(10):1800-1806. PubMed ID: 33245630 [Abstract] [Full Text] [Related]
50. Is home blood pressure monitoring useful in the management of patients with resistant hypertension? Muxfeldt ES, Barros GS, Viegas BB, Carlos FO, Salles GF. Am J Hypertens; 2015 Feb; 28(2):190-9. PubMed ID: 25143267 [Abstract] [Full Text] [Related]
51. The effects of continuous positive airway pressure on prehypertension and masked hypertension in men with severe obstructive sleep apnea. Drager LF, Pedrosa RP, Diniz PM, Diegues-Silva L, Marcondes B, Couto RB, Giorgi DM, Krieger EM, Lorenzi-Filho G. Hypertension; 2011 Mar; 57(3):549-55. PubMed ID: 21242462 [Abstract] [Full Text] [Related]
52. Assessment of hypertension in obstructive sleep apnea by ambulatory blood pressure monitoring: a systematic review and meta-analysis. Yildiz AB, Siriopol D, Vehbi S, Özgü Ö, Yağ B, Kanbay A, Kanbay M. Blood Press Monit; 2022 Oct 01; 27(5):285-296. PubMed ID: 35866496 [Abstract] [Full Text] [Related]
53. Persistence of Masked Hypertension in Chinese Patients. Wei FF, Li Y, Zhang L, Shan XL, Cheng YB, Wang JG, Yang CH, Staessen JA. Am J Hypertens; 2016 Mar 01; 29(3):326-31. PubMed ID: 26150543 [Abstract] [Full Text] [Related]
54. Automated office blood pressure and 24-h ambulatory measurements are equally associated with left ventricular mass index. Andreadis EA, Agaliotis GD, Angelopoulos ET, Tsakanikas AP, Chaveles IA, Mousoulis GP. Am J Hypertens; 2011 Jun 01; 24(6):661-6. PubMed ID: 21415839 [Abstract] [Full Text] [Related]
55. Blood pressure measurement: Should technique define targets? Hiremath S, Ramsay T, Ruzicka M. J Clin Hypertens (Greenwich); 2021 Aug 01; 23(8):1538-1546. PubMed ID: 34268883 [Abstract] [Full Text] [Related]
56. The Importance of Out-of-Office Blood Pressure Measurement, as Highlighted by the Correlation with Left Ventricular Hypertrophy in an Untreated Hypertensive Population. Antza C, Tziomalos G, Kostopoulos G, Trakatelli C, Kotsis V. Medicina (Kaunas); 2023 Sep 09; 59(9):. PubMed ID: 37763755 [Abstract] [Full Text] [Related]
57. [PASTIS study: Evaluation of an automated office blood pressure measurement]. Ayach O, Sarlon Bartoli G, Silhol F, Demari C, Vaïsse B. Ann Cardiol Angeiol (Paris); 2018 Jun 09; 67(3):180-185. PubMed ID: 29793672 [Abstract] [Full Text] [Related]
58. 'Office-hour' ambulatory blood pressure monitoring is sufficient for blood pressure diagnosis. Wong RC, Yeo TC. J Hum Hypertens; 2006 Jun 09; 20(6):440-3. PubMed ID: 16598289 [Abstract] [Full Text] [Related]
59. Comparison of Automated Office Blood Pressure With Office and Out-Off-Office Measurement Techniques. Pappaccogli M, Di Monaco S, Perlo E, Burrello J, D'Ascenzo F, Veglio F, Monticone S, Rabbia F. Hypertension; 2019 Feb 09; 73(2):481-490. PubMed ID: 30624994 [Abstract] [Full Text] [Related]
60. Blood pressure and heart rate related to sex in untreated subjects: the India ABPM study. Kaul U, Bhagwat A, Omboni S, Pancholia AK, Hardas S, Bardoloi N, Davidson D, Sivakadaksham PR, Mohan JC, Vaidyanathan PR, Natarajan S, Kapardhi LNP, Reddy KS, Solanki D, Makkar JS, Viswanathan M, Arambam P, Suvarna V, Verberk WJ. J Clin Hypertens (Greenwich); 2020 Jul 09; 22(7):1154-1162. PubMed ID: 32558208 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]