7. The Value of Electrically Evoked Stapedius Reflex in Determining the Maximum Comfort Level of a Cochlear Implant. de Andrade KCL, Muniz LF, Menezes PL, Neto SDSC, Carnaúba ATL, Leal MC. J Am Acad Audiol; 2018 Apr; 29(4):292-299. PubMed ID: 29664723 [Abstract] [Full Text] [Related]
11. Multicentre investigation on electrically evoked compound action potential and stapedius reflex: how do these objective measures relate to implant programming parameters? Van Den Abbeele T, Noël-Petroff N, Akin I, Caner G, Olgun L, Guiraud J, Truy E, Attias J, Raveh E, Belgin E, Sennaroglu G, Basta D, Ernst A, Martini A, Rosignoli M, Levi H, Elidan J, Benghalem A, Amstutz-Montadert I, Lerosey Y, De Vel E, Dhooge I, Hildesheimer M, Kronenberg J, Arnold L. Cochlear Implants Int; 2012 Feb; 13(1):26-34. PubMed ID: 22340749 [Abstract] [Full Text] [Related]
12. Stapedius reflex thresholds obtained in a free sound field as an indicator for over- and understimulation in cochlear implant listeners. Franke-Trieger A, Mattheus W, Seebacher J, Zelger P, Zahnert T, Neudert M. Int J Audiol; 2024 Sep; 63(9):695-702. PubMed ID: 37656611 [Abstract] [Full Text] [Related]
13. Stapedius reflex evoked in free sound field in cochlear implant users compared to normal-hearing listeners. Franke-Trieger A, Mattheus W, Seebacher J, Zahnert T, Neudert M. Int J Audiol; 2021 Sep; 60(9):695-703. PubMed ID: 33426977 [Abstract] [Full Text] [Related]
14. [The usefulness of intraoperatively registered, electrically evoked stapedius reflex for the programming of cochlear implants in children]. Zehnder A, Allum JH, Honegger F, Probst R. HNO; 1999 Nov; 47(11):970-5. PubMed ID: 10602787 [Abstract] [Full Text] [Related]
16. Multi-electrode sequential versus single electrode stimulation to elicit the stapedial reflex during cochlear implantation: Correlation with maximum comfort level. Guida M, Falcioni M, Di Lella F, Negri M, Fagnani E, Vincenti V. Eur Ann Otorhinolaryngol Head Neck Dis; 2019 Jun; 136(3):169-172. PubMed ID: 30878509 [Abstract] [Full Text] [Related]
19. Would an endosteal CI-electrode make sense? Comparison of the auditory nerve excitability from different stimulation sites using ESRT measurements and mathematical models. Pau HW, Grünbaum A, Ehrt K, Dahl R, Just T, van Rienen U. Eur Arch Otorhinolaryngol; 2014 Jun; 271(6):1375-81. PubMed ID: 23657576 [Abstract] [Full Text] [Related]