These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


261 related items for PubMed ID: 33573950

  • 1. Use of bioelectrical impedance spectroscopy to provide a measure of body composition in sows.
    Muller TL, Ward LC, Plush KJ, Pluske JR, D'Souza DN, Bryden WL, van Barneveld RJ.
    Animal; 2021 Mar; 15(3):100156. PubMed ID: 33573950
    [Abstract] [Full Text] [Related]

  • 2. Body composition assessment in horses using bioimpedance spectroscopy.
    Ward LC, White KJ, van der Aa Kuhle K, Cawdell-Smith J, Bryden WL.
    J Anim Sci; 2016 Feb; 94(2):533-41. PubMed ID: 27065123
    [Abstract] [Full Text] [Related]

  • 3. Suitability of Bioelectrical Based Methods to Assess Water Compartments in Recreational and Elite Athletes.
    Matias CN, Júdice PB, Santos DA, Magalhães JP, Minderico CS, Fields DA, Sardinha LB, Silva AM.
    J Am Coll Nutr; 2016 Jul; 35(5):413-21. PubMed ID: 26934568
    [Abstract] [Full Text] [Related]

  • 4. Prediction of body water compartments in preterm infants by bioelectrical impedance spectroscopy.
    Collins CT, Reid J, Makrides M, Lingwood BE, McPhee AJ, Morris SA, Gibson RA, Ward LC.
    Eur J Clin Nutr; 2013 Jan; 67 Suppl 1():S47-53. PubMed ID: 23299871
    [Abstract] [Full Text] [Related]

  • 5. Assessment of total body water and its compartments in elite judo athletes: comparison of bioelectrical impedance spectroscopy with dilution techniques.
    Gonçalves EM, Matias CN, Santos DA, Sardinha LB, Silva AM.
    J Sports Sci; 2015 Jan; 33(6):634-40. PubMed ID: 25278240
    [Abstract] [Full Text] [Related]

  • 6. New bioelectrical impedance analysis equations for children and adolescents based on the deuterium dilution technique.
    Kourkoumelis N, Grujic VR, Grabez M, Vidic A, Siksna I, Lazda I, Bajić B, Đurović D, Spiroski I, Dimitrovska M, Rito A, Mendes S, Kæstel P, Ward LC.
    Clin Nutr ESPEN; 2021 Aug; 44():402-409. PubMed ID: 34330497
    [Abstract] [Full Text] [Related]

  • 7. Validation of bio-impedance spectroscopy: effects of degree of obesity and ways of calculating volumes from measured resistance values.
    Cox-Reijven PL, Soeters PB.
    Int J Obes Relat Metab Disord; 2000 Mar; 24(3):271-80. PubMed ID: 10757619
    [Abstract] [Full Text] [Related]

  • 8. Development and validation of impedance-based equations for the prediction of total body water and fat-free mass in children aged 8-11 years.
    Ben Jemaa H, Mankaï A, Khlifi S, Minaoui R, Ghozzi D, Zediri M, Kortobi B, Karmous I, Ben Hmad H, Ben Slama F, Jamoussi H, Aguenaou H, El Kari K, Aouidet A.
    Clin Nutr; 2019 Feb; 38(1):227-233. PubMed ID: 29429643
    [Abstract] [Full Text] [Related]

  • 9. Validity of water compartments estimated using bioimpedance spectroscopy in athletes differing in hydration status.
    Francisco R, Jesus F, Gomes T, Nunes CL, Rocha P, Minderico CS, Heymsfield SB, Lukaski H, Sardinha LB, Silva AM.
    Scand J Med Sci Sports; 2021 Aug; 31(8):1612-1620. PubMed ID: 33817862
    [Abstract] [Full Text] [Related]

  • 10. Phase angle and bioelectrical impedance vector analysis in the evaluation of body composition in athletes.
    Marini E, Campa F, Buffa R, Stagi S, Matias CN, Toselli S, Sardinha LB, Silva AM.
    Clin Nutr; 2020 Feb; 39(2):447-454. PubMed ID: 30850270
    [Abstract] [Full Text] [Related]

  • 11. Determination of intracellular water by multifrequency bioelectrical impedance.
    De Lorenzo A, Candeloro N, Andreoli A, Deurenberg P.
    Ann Nutr Metab; 1995 Feb; 39(3):177-84. PubMed ID: 7486844
    [Abstract] [Full Text] [Related]

  • 12. Is bioelectrical impedance spectroscopy accurate in estimating total body water and its compartments in elite athletes?
    Matias CN, Santos DA, Gonçalves EM, Fields DA, Sardinha LB, Silva AM.
    Ann Hum Biol; 2013 Mar; 40(2):152-6. PubMed ID: 23249164
    [Abstract] [Full Text] [Related]

  • 13. Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods.
    Jaffrin MY, Morel H.
    Med Eng Phys; 2008 Dec; 30(10):1257-69. PubMed ID: 18676172
    [Abstract] [Full Text] [Related]

  • 14. Evaluation of a new bioelectrical impedance instrument for the prediction of body cell mass independently of height or weight.
    Ward LC, Doman D, Jebb SA.
    Nutrition; 2000 Sep; 16(9):745-50. PubMed ID: 10978855
    [Abstract] [Full Text] [Related]

  • 15. Development and validation of bioelectrical impedance analysis equations for prediction total body water and fat-free mass using D2O technique in Moroccan children aged between 8 and 11 years old.
    El Harchaoui I, El Hamdouchi A, Baddou I, El Menchawy I, Benjeddou K, Saeid N, Belghiti H, El Mzibri M, El Kari K, Aguenaou H.
    Eur J Clin Nutr; 2018 Dec; 72(12):1663-1672. PubMed ID: 29391592
    [Abstract] [Full Text] [Related]

  • 16. Body-water compartments measured by bio-electrical impedance spectroscopy in patients with chronic obstructive pulmonary disease.
    Baarends EM, van Marken Lichtenbelt WD, Wouters EF, Schols AM.
    Clin Nutr; 1998 Feb; 17(1):15-22. PubMed ID: 10205310
    [Abstract] [Full Text] [Related]

  • 17. Validation of bioelectrical impedance analysis for total body water assessment against the deuterium dilution technique in Asian children.
    Liu A, Byrne NM, Ma G, Nasreddine L, Trinidad TP, Kijboonchoo K, Ismail MN, Kagawa M, Poh BK, Hills AP.
    Eur J Clin Nutr; 2011 Dec; 65(12):1321-7. PubMed ID: 21731041
    [Abstract] [Full Text] [Related]

  • 18. Prediction of fat-free mass by bioelectrical impedance analysis in older adults from developing countries: a cross-validation study using the deuterium dilution method.
    Aleman-Mateo H, Rush E, Esparza-Romero J, Ferriolli E, Ramirez-Zea M, Bour A, Yuchingtat G, Ndour R, Mokhtar N, Valencia ME, Schoeller DA.
    J Nutr Health Aging; 2010 Jun; 14(6):418-26. PubMed ID: 20617282
    [Abstract] [Full Text] [Related]

  • 19. Evaluation of bioimpedance spectroscopy for measurements of body water distribution in healthy women before, during, and after pregnancy.
    Lof M, Forsum E.
    J Appl Physiol (1985); 2004 Mar; 96(3):967-73. PubMed ID: 14634029
    [Abstract] [Full Text] [Related]

  • 20. Accuracy of bioelectrical impedance spectroscopy in measuring changes in body composition during severe weight loss.
    Cox-Reijven PL, van Kreel B, Soeters PB.
    JPEN J Parenter Enteral Nutr; 2002 Mar; 26(2):120-7. PubMed ID: 11873761
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 14.