These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


554 related items for PubMed ID: 33909724

  • 21.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 22.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 23. Fatigue fracture resistance of titanium and chairside CAD-CAM zirconia implant abutments supporting zirconia crowns: An in vitro comparative and finite element analysis study.
    Giner S, Bartolomé JF, Gomez-Cogolludo P, Castellote C, Pradíes G.
    J Prosthet Dent; 2021 Mar; 125(3):503.e1-503.e9. PubMed ID: 33243472
    [Abstract] [Full Text] [Related]

  • 24. In vitro performance of implant-supported monolithic zirconia crowns: Influence of patient-specific tooth-coloured abutments with titanium adhesive bases.
    Rosentritt M, Rembs A, Behr M, Hahnel S, Preis V.
    J Dent; 2015 Jul; 43(7):839-45. PubMed ID: 25953721
    [Abstract] [Full Text] [Related]

  • 25.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 26.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 27. Comparison of fracture resistance of pressable metal ceramic custom implant abutments with CAD/CAM commercially fabricated zirconia implant abutments.
    Kim S, Kim HI, Brewer JD, Monaco EA.
    J Prosthet Dent; 2009 Apr; 101(4):226-30. PubMed ID: 19328275
    [Abstract] [Full Text] [Related]

  • 28. Failure Load of Monolithic Lithium Disilicate Implant-Supported Single Crowns Bonded to Ti-base Abutments versus to Customized Ceramic Abutments after Fatigue.
    Spitznagel FA, Bonfante EA, Vollmer F, Gierthmuehlen PC.
    J Prosthodont; 2022 Feb; 31(2):136-146. PubMed ID: 33870577
    [Abstract] [Full Text] [Related]

  • 29. Comparison of fracture resistance of pressable metal ceramic custom implant abutment with a commercially fabricated CAD/CAM zirconia implant abutment.
    Protopapadaki M, Monaco EA, Kim HI, Davis EL.
    J Prosthet Dent; 2013 Nov; 110(5):389-96. PubMed ID: 24011801
    [Abstract] [Full Text] [Related]

  • 30.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 31. Fracture Strength of Monolithic All-Ceramic Crowns on Titanium Implant Abutments.
    Weyhrauch M, Igiel C, Scheller H, Weibrich G, Lehmann KM.
    Int J Oral Maxillofac Implants; 2016 Nov; 31(2):304-9. PubMed ID: 27004277
    [Abstract] [Full Text] [Related]

  • 32. Mechanical behavior of nano-hybrid composite in comparison to lithium disilicate as posterior cement-retained implant-supported crowns restoring different abutments.
    Elsayed A, Yazigi C, Kern M, Chaar MS.
    Dent Mater; 2021 Aug; 37(8):e435-e442. PubMed ID: 33875247
    [Abstract] [Full Text] [Related]

  • 33.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 34. Effect of abutment design on fracture resistance of resin-matrix ceramic crowns for dental implant restoration: an in vitro study.
    Lin J, Cai P, Zhuo Y, Lin L, Zheng Z.
    BMC Oral Health; 2023 Jun 21; 23(1):410. PubMed ID: 37344826
    [Abstract] [Full Text] [Related]

  • 35.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 36. Mechanical stability and technical outcomes of monolithic CAD/CAM fabricated abutment-crowns supported by titanium bases: An in vitro study.
    Pitta J, Hjerppe J, Burkhardt F, Fehmer V, Mojon P, Sailer I.
    Clin Oral Implants Res; 2021 Feb 21; 32(2):222-232. PubMed ID: 33258267
    [Abstract] [Full Text] [Related]

  • 37.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 38. Stress behavior of an anterior single implant restored with high-performance polymer abutments under immediate and delayed loading: A 3D FEA study.
    Diken Turksayar AA, Donmez MB.
    J Prosthodont; 2023 Feb 21; 32(2):132-138. PubMed ID: 36007157
    [Abstract] [Full Text] [Related]

  • 39. Fracture strength of various titanium-based, CAD-CAM and PFM implant crowns.
    DuVall NB, DeReis SP, Vandewalle KS.
    J Esthet Restor Dent; 2021 Apr 21; 33(3):522-530. PubMed ID: 33174333
    [Abstract] [Full Text] [Related]

  • 40. Effect of aging on fracture resistance and torque loss of restorations supported by zirconia and polyetheretherketone abutments: An in vitro study.
    Ghodsi S, Tanous M, Hajimahmoudi M, Mahgoli H.
    J Prosthet Dent; 2021 Mar 21; 125(3):501.e1-501.e6. PubMed ID: 33248675
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 28.