These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
353 related items for PubMed ID: 3400759
1. Oculab Tono-Pen, Goldmann applanation tonometry, and pneumatic tonometry for intraocular pressure assessment in gas-filled eyes. Hines MW, Jost BF, Fogelman KL. Am J Ophthalmol; 1988 Aug 15; 106(2):174-9. PubMed ID: 3400759 [Abstract] [Full Text] [Related]
2. A clinical comparison of the Oculab Tono-Pen with the Goldmann applanation tonometer in eyes filled with silicone oil. Alfaro DV, Tran VT. Retina; 1991 Aug 15; 11(2):219-20. PubMed ID: 1925086 [Abstract] [Full Text] [Related]
6. Comparison of the Tono-Pen to the Goldmann applanation tonometer. Frenkel RE, Hong YJ, Shin DH. Arch Ophthalmol; 1988 Jun 15; 106(6):750-3. PubMed ID: 3369998 [Abstract] [Full Text] [Related]
7. Evaluation of the Tono-Pen 2 and the X-Pert noncontact tonometers in cataract surgery. Denis P, Nordmann JP, Bertin V, Gayraud JM, Laroche L, Saraux H. Ophthalmologica; 1993 Jun 15; 207(3):155-61. PubMed ID: 8278182 [Abstract] [Full Text] [Related]
8. Clinical comparison of the Oculab Tono-Pen to the Goldmann applanation tonometer. Kao SF, Lichter PR, Bergstrom TJ, Rowe S, Musch DC. Ophthalmology; 1987 Dec 15; 94(12):1541-4. PubMed ID: 3431824 [Abstract] [Full Text] [Related]
9. Assessment of intraocular pressure in vitrectomized gas-containing eyes. A clinical and manometric comparison of the Tono-Pen to the pneumotonometer. Lim JI, Blair NP, Higginbotham EJ, Farber MD, Shaw WE, Garretson BR. Arch Ophthalmol; 1990 May 15; 108(5):684-8. PubMed ID: 2334326 [Abstract] [Full Text] [Related]
11. Intraocular pressure assessment in gas-filled eyes following vitrectomy. Poliner LS, Schoch LH. Arch Ophthalmol; 1987 Feb 15; 105(2):200-2. PubMed ID: 3028345 [Abstract] [Full Text] [Related]
12. Evaluation of the Tono-Pen and the Pulsair tonometers. Armstrong TA. Am J Ophthalmol; 1990 Jun 15; 109(6):716-20. PubMed ID: 2346202 [Abstract] [Full Text] [Related]
13. Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas. Kontadakis GA, Pennos A, Pentari I, Kymionis GD, Pallikaris IG, Ginis H. Ther Adv Ophthalmol; 2020 Jun 15; 12():2515841420923190. PubMed ID: 32577607 [Abstract] [Full Text] [Related]
16. Pascal dynamic contour tonometry versus goldmann applanation tonometry in gas and air-filled eyes after vitrectomy surgery. Donaldson MJ, Bhatnagar P, Dhrami-Gavazi E, Santos RA, Barile GR, Del Priore LV, Iranmanesh R, Schiff WM, Chang S. Retina; 2009 Apr 15; 29(4):481-6. PubMed ID: 18936717 [Abstract] [Full Text] [Related]
17. Accuracy and precision of the Tono-Pen in measuring intraocular pressure after keratoplasty and epikeratophakia and in scarred corneas. Rootman DS, Insler MS, Thompson HW, Parelman J, Poland D, Unterman SR. Arch Ophthalmol; 1988 Dec 15; 106(12):1697-700. PubMed ID: 3058102 [Abstract] [Full Text] [Related]
18. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen. Bhan A, Browning AC, Shah S, Hamilton R, Dave D, Dua HS. Invest Ophthalmol Vis Sci; 2002 May 15; 43(5):1389-92. PubMed ID: 11980851 [Abstract] [Full Text] [Related]
19. Comparison of Scleral Tono-Pen Intraocular Pressure Measurements with Goldmann Applanation Tonometry. Badakere SV, Choudhari NS, Rao HL, Chary CR, Garudadri CS, Senthil S. Optom Vis Sci; 2018 Feb 15; 95(2):129-135. PubMed ID: 29370020 [Abstract] [Full Text] [Related]