1. Filtering-induced time shifts in photoplethysmography pulse features measured at different body sites: the importance of filter definition and standardization. Liu H, Allen J, Khalid SG, Chen F, Zheng D. Physiol Meas; 2021 Jul 28; 42(7):. PubMed ID: 34111855 [Abstract] [Full Text] [Related]
2. Filtering-induced changes of pulse transmit time across different ages: a neglected concern in photoplethysmography-based cuffless blood pressure measurement. Liao S, Liu H, Lin WH, Zheng D, Chen F. Front Physiol; 2023 Jul 28; 14():1172150. PubMed ID: 37560157 [Abstract] [Full Text] [Related]
3. Optimal fiducial points for pulse rate variability analysis from forehead and finger photoplethysmographic signals. Peralta E, Lazaro J, Bailon R, Marozas V, Gil E. Physiol Meas; 2019 Feb 26; 40(2):025007. PubMed ID: 30669123 [Abstract] [Full Text] [Related]
4. Estimation of phase distortions of the photoplethysmographic signal in digital IIR filtering. Lapitan DG, Rogatkin DA, Molchanova EA, Tarasov AP. Sci Rep; 2024 Mar 19; 14(1):6546. PubMed ID: 38503856 [Abstract] [Full Text] [Related]
6. Coherence between Decomposed Components of Wrist and Finger PPG Signals by Imputing Missing Features and Resolving Ambiguous Features. Tsai PY, Huang CH, Guo JW, Li YC, Wu AA, Lin HJ, Wang TD. Sensors (Basel); 2021 Jun 24; 21(13):. PubMed ID: 34202597 [Abstract] [Full Text] [Related]
7. Effects of using different algorithms and fiducial points for the detection of interbeat intervals, and different sampling rates on the assessment of pulse rate variability from photoplethysmography. Mejía-Mejía E, May JM, Kyriacou PA. Comput Methods Programs Biomed; 2022 May 24; 218():106724. PubMed ID: 35255373 [Abstract] [Full Text] [Related]
18. Pulse arrival time (PAT) measurement based on arm ECG and finger PPG signals - comparison of PPG feature detection methods for PAT calculation. Rajala S, Ahmaniemi T, Lindholm H, Taipalus T. Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul 30; 2017():250-253. PubMed ID: 29059857 [Abstract] [Full Text] [Related]
19. Systolic blood pressure estimation using PPG and ECG during physical exercise. Sun S, Bezemer R, Long X, Muehlsteff J, Aarts RM. Physiol Meas; 2016 Dec 30; 37(12):2154-2169. PubMed ID: 27841157 [Abstract] [Full Text] [Related]