These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. [Hemodynamics after mitral valve replacement with Starr-Edwards, Björk-Shiley and Lillehei-Kaster protheses (author's transl)]. Haerten K, Both A, Lück J, Herzer J, Loogen F. Z Kardiol; 1977 May; 66(5):242-6. PubMed ID: 878552 [Abstract] [Full Text] [Related]
23. Evaluation of various mechanical heart values in the mitral and aortic positions. Iwahashi K, Ota T, Okada M, Tsukube T, Matsuda H. Kobe J Med Sci; 1993 Jun; 39(3):81-93. PubMed ID: 8255076 [Abstract] [Full Text] [Related]
24. In-vitro measurements of the regurgitation of mechanical mitral heart valve prostheses in case of atrial fibrillation. Mouret F, Garitey V, Fuseri J, Rieu R. J Heart Valve Dis; 2001 Mar; 10(2):264-8. PubMed ID: 11297214 [Abstract] [Full Text] [Related]
25. A new design for polyurethane heart valves. Butterfield M, Wheatley DJ, Williams DF, Fisher J. J Heart Valve Dis; 2001 Jan; 10(1):105-10. PubMed ID: 11206756 [Abstract] [Full Text] [Related]
26. [Doppler echocardiographic evaluation of functional parameters of mechanical and biological valve prostheses]. De Gaetano G, Barberis L, Dottori V, Parodi E, Passerone GC, Lijoi A, Kandil H, Gnecco G, Badano L, Venere G. Minerva Cardioangiol; 1993 Sep; 41(9):365-70. PubMed ID: 8259231 [Abstract] [Full Text] [Related]
27. In vitro comparison of bileaflet aortic heart valve prostheses. St. Jude Medical, CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves. Reul H, van Son JA, Steinseifer U, Schmitz B, Schmidt A, Schmitz C, Rau G. J Thorac Cardiovasc Surg; 1993 Sep; 106(3):412-20. PubMed ID: 8361181 [Abstract] [Full Text] [Related]
28. Hydrodynamic function of tilting disc prostheses and bileaflet valves in double valve replacement. Strüber M, Campbell A, Richard G, Laas J. Eur J Cardiothorac Surg; 1996 Sep; 10(6):422-7. PubMed ID: 8817137 [Abstract] [Full Text] [Related]
29. [In vitro hydrodynamic characteristics of heart valves in tricuspid position]. Yamada T. Nihon Kyobu Geka Gakkai Zasshi; 1990 Jul; 38(7):1176-82. PubMed ID: 2212780 [Abstract] [Full Text] [Related]
30. Hydrodynamic function of ten prosthetic heart valves in the aortic position. Fisher J, Wheatley DJ. Clin Phys Physiol Meas; 1988 Nov; 9(4):307-17. PubMed ID: 3233885 [Abstract] [Full Text] [Related]
31. Variability of regurgitation in Björk-Shiley mitral valves and relationship to disc occluder design: an in vitro two-dimensional color-Doppler flow mapping study. Lindower PD, Dellsperger KC, Johnson B, Chandran KB, Vandenberg BF. J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S178-83. PubMed ID: 8905518 [Abstract] [Full Text] [Related]
32. The Björk-Shiley Delrin tilting disc heart valve: historical perspective, design and need for scientific analyses after 25 years. Wieting DW. J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S157-68. PubMed ID: 8905516 [Abstract] [Full Text] [Related]
33. Different tilting disc valves show similar rotation-dependent impairment in hemodynamic performance under a tilted implantation position. Hartrumpf M, Kuehnel RU, Puchner R, Wendt MO, Pohl M, Albes JM. Thorac Cardiovasc Surg; 2005 Oct; 53(5):274-80. PubMed ID: 16208612 [Abstract] [Full Text] [Related]
34. Closing sounds and related complaints after heart valve replacement with St Jude Medical, Duromedics Edwards, Björk-Shiley Monostrut, and Carbomedics prostheses. Moritz A, Steinseifer U, Kobinia G, Neuwirth-Riedl K, Wolters H, Reul H, Wolner E. Br Heart J; 1992 Jun; 67(6):460-5. PubMed ID: 1622695 [Abstract] [Full Text] [Related]
35. Hemodynamic performance of the new St. Jude Medical Epic Supra porcine bioprosthesis in comparison to the Medtronic Mosaic on the basis of patient annulus diameter. Ruzicka DJ, Eichinger WB, Hettich IM, Bleiziffer S, Bauernschmitt R, Lange R. J Heart Valve Dis; 2008 Jul; 17(4):426-33; discussion 434. PubMed ID: 18751473 [Abstract] [Full Text] [Related]
36. Six month postoperative hemodynamics of the Hancock heterograft and the Björk-Shiley prosthesis: results of a Veterans Administration cooperative prospective randomized trial. Khuri SF, Folland ED, Sethi GK, Souchek J, Oprian C, Wong M, Burchfiel C, Henderson WG, Hammermeister KE. J Am Coll Cardiol; 1988 Jul; 12(1):8-18. PubMed ID: 3288680 [Abstract] [Full Text] [Related]
37. [Functional transvalvular regurgitation in patients with Björk-Shiley aortic valves: a pulsed Doppler echocardiographic study]. Yoshida K, Yoshikawa J, Kato H, Yanagihara K, Okumachi F, Koizumi K, Shiratori K, Asaka T, Suzuki K, Inanami H. J Cardiogr; 1985 Dec; 15(4):1137-44. PubMed ID: 3841896 [Abstract] [Full Text] [Related]
38. Clinical performance of Bjork-Shiley mechanical heart valves: a perspective on outlet strut fractures in the 60 degrees and 70 degrees convexo-concave disc models. Scully HE, Damle A, Goldman BS, Tong C, Azuma J, Mickleborough LL, Schwartz L, Baird RJ. Can J Cardiol; 1988 Oct; 4(7):386-92. PubMed ID: 3228767 [Abstract] [Full Text] [Related]
39. A novel pulse duplicator system: evaluation of different valve prostheses. Haaf P, Steiner M, Attmann T, Pfister G, Cremer J, Lutter G. Thorac Cardiovasc Surg; 2009 Feb; 57(1):10-7. PubMed ID: 19169990 [Abstract] [Full Text] [Related]