These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. [Technique for postoperative irradiation of patients with breast cancer using electron and cobalt beams]. Morawska-Kaczyńska M, Kukołowicz P. Nowotwory; 1990; 40(4):275-83. PubMed ID: 2277779 [Abstract] [Full Text] [Related]
4. [Photon or electron irradiation of the internal breast lymph node chain. Experimental dosimetry and clinical implications]. Conte G, Marchetti C, Polico R, Stea L. Radiol Med; 1990 Oct; 80(4 Suppl 1):81-5. PubMed ID: 2251424 [Abstract] [Full Text] [Related]
9. [A proposal for the treatment technique for the breast and regional lymph nodes in patients with conservatively operated neoplasms]. Guenzi M, Sanguineti G, Botto F, Ghiso G, Andreucci L, Vitale V. Radiol Med; 1990 Oct 15; 80(4 Suppl 1):77-80. PubMed ID: 2251423 [Abstract] [Full Text] [Related]
10. [Evaluation of irradiation techniques in breast carcinoma using dose-volume histograms. Comparison of the heart and lung exposure]. Pakisch B, Stücklschweiger G, Leitner H, Poier E, Poschauko J, Ottl M, Hackl A. Strahlenther Onkol; 1991 Mar 15; 167(3):158-64. PubMed ID: 1901669 [Abstract] [Full Text] [Related]
11. Unplanned irradiation of internal mammary lymph nodes in breast cancer. Kanyilmaz G, Aktan M, Koc M, Demir H, Demir LS. Radiol Med; 2017 Jun 15; 122(6):405-411. PubMed ID: 28255809 [Abstract] [Full Text] [Related]
13. To treat or not to treat the internal mammary nodes: a possible compromise. Marks LB, Hebert ME, Bentel G, Spencer DP, Sherouse GW, Prosnitz LR. Int J Radiat Oncol Biol Phys; 1994 Jul 01; 29(4):903-9. PubMed ID: 8040041 [Abstract] [Full Text] [Related]
14. Contralateral breast doses following radiotherapy of the breast and regional lymph nodes: Measurements and treatment planning calculations. Johansen S, Olsen DR, Danielsen T, Malinen E. Radiother Oncol; 2007 Mar 01; 82(3):332-6. PubMed ID: 16962677 [Abstract] [Full Text] [Related]
16. [Oblique incidence of electron beams--comparisons between calculated and measured dose distributions]. Karcher J, Paulsen F, Christ G. Z Med Phys; 2005 Mar 01; 15(1):6-12. PubMed ID: 15830779 [Abstract] [Full Text] [Related]
17. Optimization of combined electron and photon beams for breast cancer. Xiong W, Li J, Chen L, Price RA, Freedman G, Ding M, Qin L, Yang J, Ma CM. Phys Med Biol; 2004 May 21; 49(10):1973-89. PubMed ID: 15214536 [Abstract] [Full Text] [Related]
20. Number and orientation of beams in inversely planned intensity-modulated radiotherapy of the female breast and the parasternal lymph nodes. Thilmann C, Zabel A, Milker-Zabel S, Schlegel W, Wannenmacher M, Debus J. Am J Clin Oncol; 2003 Oct 21; 26(5):e136-43. PubMed ID: 14528088 [Abstract] [Full Text] [Related] Page: [Next] [New Search]