These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
158 related items for PubMed ID: 34610595
1. Comparison of the Clinical Effectiveness of AN69-oXiris versus AN69-ST Filter in Septic Patients: A Single-Centre Study. Zang S, Chen Q, Zhang Y, Xu L, Chen J. Blood Purif; 2022; 51(7):617-629. PubMed ID: 34610595 [Abstract] [Full Text] [Related]
2. The clinical efficacy and suitable implementation of two extracorporeal blood purification therapies: AN69-oXiris versus PMX-HP. Kim HS, Chung YJ, Lee GR, Kim EY. Front Med (Lausanne); 2024; 11():1344893. PubMed ID: 38357649 [Abstract] [Full Text] [Related]
3. Effect of CRRT with oXiris filter on hemodynamic instability in surgical septic shock with AKI: A pilot randomized controlled trial. Feng J, Zhang S, Ai T, Wang L, Gao Y, Li W, Zhu M. Int J Artif Organs; 2022 Oct; 45(10):801-808. PubMed ID: 35864718 [Abstract] [Full Text] [Related]
4. Effect of oXiris-CVVH on the Clinical Outcomes of Patients with Septic Shock: An Inverse Probability of Treatment-Weighted Analysis. Xie J, Xiao W, Lin J. Blood Purif; 2022 Oct; 51(12):972-989. PubMed ID: 35649340 [Abstract] [Full Text] [Related]
5. The haemodynamic effects of oXiris haemofilter in septic shock patients requiring renal support: A single-centre experience. Lumlertgul N, Srisawat N. Int J Artif Organs; 2021 Jan; 44(1):17-24. PubMed ID: 32393096 [Abstract] [Full Text] [Related]
6. Endotoxin and cytokine reducing properties of the oXiris membrane in patients with septic shock: A randomized crossover double-blind study. Broman ME, Hansson F, Vincent JL, Bodelsson M. PLoS One; 2019 Jan; 14(8):e0220444. PubMed ID: 31369593 [Abstract] [Full Text] [Related]
7. COMPARISON OF OXIRIS AND CONVENTIONAL CONTINUOUS RENAL REPLACEMENT THERAPY IN MANAGING SEVERE ABDOMINAL INFECTIONS: IMPACT ON SEPTIC SHOCK MORTALITY. Liao XY, Chen YT, Liu MJ, Liao QX, Lin JD, Lin HR, Huang YH, Zhou Y. Shock; 2024 Oct 01; 62(4):529-538. PubMed ID: 39158926 [Abstract] [Full Text] [Related]
8. [Usage of oXiris hemofilter for septic shock patients: a single-center experience]. Zhang C, Sun B, Lin T, Wang W, Jin Y, Liu S, Zhang J, Wang Z, Liu C. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2019 Dec 01; 31(12):1531-1534. PubMed ID: 32029043 [Abstract] [Full Text] [Related]
9. Application of oXiris-continuous hemofiltration adsorption in patients with sepsis and septic shock: A single-centre experience in China. Zhou Y, Wu C, Ouyang L, Peng Y, Zhong D, Xiang X, Li J. Front Public Health; 2022 Dec 01; 10():1012998. PubMed ID: 36249210 [Abstract] [Full Text] [Related]
10. Continuous Renal Replacement Therapy With Adsorbing Filter oXiris in Acute Kidney Injury With Septic Shock: A Retrospective Observational Study. Guan M, Wang H, Tang X, Zhao Y, Wang F, Zhang L, Fu P. Front Med (Lausanne); 2022 Dec 01; 9():789623. PubMed ID: 35463014 [Abstract] [Full Text] [Related]
12. Early use of endotoxin absorption by oXiris in abdominal septic shock: A case report. Wei T, Chen Z, Li P, Tang X, Marshall MR, Zhang L, Fu P. Medicine (Baltimore); 2020 Jul 10; 99(28):e19632. PubMed ID: 32664051 [Abstract] [Full Text] [Related]
13. Continuous renal replacement therapy with the adsorptive oXiris filter may be associated with the lower 28-day mortality in sepsis: a systematic review and meta-analysis. Wang G, He Y, Guo Q, Zhao Y, He J, Chen Y, Chen W, Zhou Y, Peng Z, Deng K, Guan J, Xie W, Chang P, Liu Z. Crit Care; 2023 Jul 09; 27(1):275. PubMed ID: 37424026 [Abstract] [Full Text] [Related]
14. The effect of the AN69 ST100 versus oXiris® membrane on filter life during CRRT for non-anticoagulated liver failure patients. Naorungroj T, Baldwin I, Eastwood G, Bellomo R. Int J Artif Organs; 2023 Apr 09; 46(4):209-214. PubMed ID: 36895128 [Abstract] [Full Text] [Related]
15. Successful treatment of gastrointestinal infection-induced septic shock using the oXiris® hemofilter: A case report. Li Y, Ji XJ, Jing DY, Huang ZH, Duan ML. World J Clin Cases; 2021 Sep 26; 9(27):8157-8163. PubMed ID: 34621875 [Abstract] [Full Text] [Related]
16. Continuous Renal Replacement Therapy with the Adsorbing Filter oXiris in Septic Patients: A Case Series. Turani F, Barchetta R, Falco M, Busatti S, Weltert L. Blood Purif; 2019 Sep 26; 47 Suppl 3():1-5. PubMed ID: 30982024 [Abstract] [Full Text] [Related]
17. [The effect of AN69 ST membrane on filter lifetime in continuous renal replacement therapy without anticoagulation in patients with high risk of bleeding]. Yin Y, Zhao C, Hu Z, Wei S, Huo Y. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2015 May 26; 27(5):343-8. PubMed ID: 26003637 [Abstract] [Full Text] [Related]
18. oXiris® Use in Septic Shock: Experience of Two French Centres. Schwindenhammer V, Girardot T, Chaulier K, Grégoire A, Monard C, Huriaux L, Illinger J, Leray V, Uberti T, Crozon-Clauzel J, Rimmelé T. Blood Purif; 2019 May 26; 47 Suppl 3():1-7. PubMed ID: 30982028 [Abstract] [Full Text] [Related]
19. Application of Different Continuous Renal Replacement Therapy Hemofilter in Patients with Septic Shock Complicated with Acute Renal Injury. Liu S, Cao Q, Sun R, Wang N. Iran J Public Health; 2022 Oct 26; 51(10):2317-2324. PubMed ID: 36415800 [Abstract] [Full Text] [Related]