62. The effects of anticoagulation and processing on assays of IL-6, sIL-6R, sIL-2R and soluble transferrin receptor. De Jongh R, Vranken J, Vundelinckx G, Bosmans E, Maes M, Heylen R. Cytokine; 1997 Sep; 9(9):696-701. PubMed ID: 9325019 [Abstract] [Full Text] [Related]
63. Metabolite Ratios as Quality Indicators for Pre-Analytical Variation in Serum and EDTA Plasma. Heiling S, Knutti N, Scherr F, Geiger J, Weikert J, Rose M, Jahns R, Ceglarek U, Scherag A, Kiehntopf M. Metabolites; 2021 Sep 18; 11(9):. PubMed ID: 34564454 [Abstract] [Full Text] [Related]
64. Recentrifugation of Lithium Heparin Gel Separator Tubes up to 8 h after Blood Collection Has No Relevant Influence on the Stability of 30 Routine Biochemical Analytes. van Balveren JA, Gemen EFA, Kusters R. J Appl Lab Med; 2019 Mar 18; 3(5):864-869. PubMed ID: 31639761 [Abstract] [Full Text] [Related]
68. PLASMA SEPARATOR TUBES DO NOT HAVE ANY OVERT EFFECTS ON ROUTINE PLASMA CHEMISTRY DATA OF GREEN SEA TURTLES (CHELONIA MYDAS). Glassman AR, Zachariah TT, Patterson JL, Gann SL, Montgomery N, Stacy NI. J Zoo Wildl Med; 2021 Dec 18; 52(4):1241-1246. PubMed ID: 34998295 [Abstract] [Full Text] [Related]
70. Evaluation of three different specimen types (serum, plasma lithium heparin and serum gel separator) for analysis of certain analytes: clinical significance of differences in results and efficiency in use. O'Keane MP, Cunningham SK. Clin Chem Lab Med; 2006 Dec 18; 44(5):662-8. PubMed ID: 16681442 [Abstract] [Full Text] [Related]
71. Effects of storage temperature and time before centrifugation on ionized calcium in blood collected in plain vacutainer tubes and silicone-separator (SST) tubes. Toffaletti J, Blosser N, Kirvan K. Clin Chem; 1984 Apr 18; 30(4):553-6. PubMed ID: 6705198 [Abstract] [Full Text] [Related]
74. Absorption of therapeutic drugs by barrier gels in serum separator blood collection tubes. Volume- and time-dependent reduction in total and free drug concentrations. Dasgupta A, Dean R, Saldana S, Kinnaman G, McLawhon RW. Am J Clin Pathol; 1994 Apr 18; 101(4):456-61. PubMed ID: 8160636 [Abstract] [Full Text] [Related]
76. Using BD Vacutainer CD4 Stabilization Tubes for Absolute Cluster of Differentiation Type 4 Cell Count Measurement on BD FacsCount and Partec Cyflow Cytometers: A Method Comparison Study from Zimbabwe. Vogt F, Van den Bergh R, Bernasconi A, Moyo B, Havazvidi L, Bastard M, Flevaud L, Taziwa F, Makondo E, Mtapuri-Zinyowera S. PLoS One; 2015 Apr 18; 10(8):e0136537. PubMed ID: 26295802 [Abstract] [Full Text] [Related]
78. The effect of pre-analytical variability on the measurement of MRM-MS-based mid- to high-abundance plasma protein biomarkers and a panel of cytokines. Aguilar-Mahecha A, Kuzyk MA, Domanski D, Borchers CH, Basik M. PLoS One; 2012 Apr 18; 7(6):e38290. PubMed ID: 22701622 [Abstract] [Full Text] [Related]
79. Continual improvement of the pre-analytical process in a public health laboratory with quality indicators-based risk management. Karadağ C, Demirel NN. Clin Chem Lab Med; 2019 Sep 25; 57(10):1530-1538. PubMed ID: 31050651 [Abstract] [Full Text] [Related]
80. Thrombin-mediated degradation of parathyroid hormone in serum tubes. La'ulu SL, Straseski JA, Schmidt RL, Genzen JR. Clin Chim Acta; 2014 Nov 01; 437():191-6. PubMed ID: 25086279 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]