1. Routine monitoring of cyclosporine in whole blood and in kidney tissue using high performance liquid chromatography. Kahn GC, Shaw LM, Kane MD. J Anal Toxicol; 1986; 10(1):28-34. PubMed ID: 3512913 [Abstract] [Full Text] [Related]
2. Cyclosporine measurement in transplantation. Sanghvi A, Seltman H, Diven W. Arch Pathol Lab Med; 1985 Dec; 109(12):1072-5. PubMed ID: 3907588 [Abstract] [Full Text] [Related]
3. Semi-automated high-performance liquid chromatographic determination of cyclosporine A in whole blood using one-step sample purification and column-switching. Hamilton G, Roth E, Wallisch E, Tichy F. J Chromatogr; 1985 Jun 14; 341(2):411-9. PubMed ID: 3897257 [Abstract] [Full Text] [Related]
4. Monitoring of blood levels of cyclosporine in renal and cardiac transplant recipients--comparison of HPLC to Incstar CYCLO-Trac SP RIA. Loo JC, Gallicano KD, McGilveray IJ, Beaudoin N, Jindal SL. Clin Biochem; 1991 Feb 14; 24(1):49-53. PubMed ID: 2060132 [Abstract] [Full Text] [Related]
5. Therapeutic cyclosporine monitoring: comparison of radioimmunoassay and high-performance liquid chromatography methods in organ transplant recipients. Hirvisalo EL, Kivistö KT, Neuvonen PJ. Ther Drug Monit; 1990 Jul 14; 12(4):353-8. PubMed ID: 2396309 [Abstract] [Full Text] [Related]
6. Specific 3H radioimmunoassay with a monoclonal antibody for monitoring cyclosporine in blood. Ball PE, Munzer H, Keller HP, Abisch E, Rosenthaler J. Clin Chem; 1988 Feb 14; 34(2):257-60. PubMed ID: 3277744 [Abstract] [Full Text] [Related]
7. Micro method for liquid chromatographic determination of cyclosporin A in whole blood with use of a rapid extraction procedure. Sadeg N, Chuong PH, Claude JR, Hamon M. J Anal Toxicol; 1991 Feb 14; 15(2):95-7. PubMed ID: 2051752 [Abstract] [Full Text] [Related]
8. Solid-phase extraction and liquid chromatography for improved assay of cyclosporine in whole blood or plasma. Kabra PM, Wall JH, Blanckaert N. Clin Chem; 1985 Oct 14; 31(10):1717-20. PubMed ID: 4042335 [Abstract] [Full Text] [Related]
9. Measurement of cyclosporine concentrations in whole blood: HPLC and radioimmunoassay with a specific monoclonal antibody and 3H- or 125I-labeled ligand compared. Wolf BA, Daft MC, Koenig JW, Flye MW, Turk JW, Scott MG. Clin Chem; 1989 Jan 14; 35(1):120-4. PubMed ID: 2642760 [Abstract] [Full Text] [Related]
10. Evaluation of the Incstar Cyclo-Trac sp kit for the determination of cyclosporine in blood. Plebani M, Masiero M, Paleari CD, Faggian D, Burlina A. Clin Biochem; 1989 Oct 14; 22(5):345-7. PubMed ID: 2805337 [Abstract] [Full Text] [Related]
11. Simple and specific isocratic liquid chromatographic procedure for cyclosporine A determination in whole blood, compared with radioimmunoassay. Klíma J, Petrásek R, Kocandrle V. J Chromatogr; 1987 Jan 09; 385():357-61. PubMed ID: 3549751 [No Abstract] [Full Text] [Related]
12. New automated high-performance liquid chromatographic analysis of cyclosporin A and G in human serum. Wallemacq PE, Lesne M. J Chromatogr; 1987 Jan 23; 413():131-40. PubMed ID: 3558662 [Abstract] [Full Text] [Related]
13. Fully automated high-performance liquid chromatographic determination using pretreatment polymer column and column-switching for fast, daily, routine bedside monitoring of cyclosporine in whole blood. Uchida K, Yamada N, Orihara A, Tominaga Y, Tanaka Y, Hayashi S, Kondo T, Nishikawa Y, Morozumi K, Satake M. Transplant Proc; 1989 Feb 23; 21(1 Pt 1):901-3. PubMed ID: 2705254 [No Abstract] [Full Text] [Related]
14. Cyclosporine metabolites in human blood and renal tissue. Rosano TG, Freed BM, Pell MA, Lempert N. Transplant Proc; 1986 Dec 23; 18(6 Suppl 5):35-40. PubMed ID: 3538572 [No Abstract] [Full Text] [Related]
15. Ciclosporin monitoring in kidney-transplanted children: high-performance liquid chromatography versus radioimmunoassay. Khoss AE, Hamilton G, Illievich V, Mühlbacher F, Roth E, Steger H, Wladika W, Howanietz H, Balzar E. Child Nephrol Urol; 1986 Dec 23; 9(1-2):42-5. PubMed ID: 3075152 [Abstract] [Full Text] [Related]
16. Cyclosporine determinations in heart and kidney transplant patients: comparison of high-performance liquid chromatography, polyclonal, and monoclonal methods. Subbarao MN, Swanson JR, Mueggler PA. Ther Drug Monit; 1989 Dec 23; 11(1):53-6. PubMed ID: 2643203 [Abstract] [Full Text] [Related]
17. Therapeutic monitoring of cyclosporine: impact of a change in standards on 125I-monoclonal RIA performance in comparison with liquid chromatography. Keown PA, Glenn J, Denegri J, Maciejewska U, Seccombe D, Stawecki M, Freeman D, Stiller C, Shackleton C, Cameron E. Clin Chem; 1990 May 23; 36(5):804-7. PubMed ID: 2337993 [Abstract] [Full Text] [Related]
18. Cyclosporine and metabolites in blood from renal allograft recipients with nephrotoxicity, rejection, or good renal function: comparative high-performance liquid chromatography and monoclonal radioimmunoassay studies. Rosano TG, Pell MA, Freed BM, Dybas MT, Lempert N. Transplant Proc; 1988 Apr 23; 20(2 Suppl 2):330-8. PubMed ID: 3284076 [No Abstract] [Full Text] [Related]
19. A prospective study of cyclosporine concentration in relation to its therapeutic effect and toxicity after renal transplantation. Lindholm A, Dahlqvist R, Groth GG, Sjöqvist F. Br J Clin Pharmacol; 1990 Sep 23; 30(3):443-52. PubMed ID: 2223423 [Abstract] [Full Text] [Related]