6. Two-site evaluation of a new workflow for the detection of malignant cells on the Sysmex XN-1000 body fluid analyzer. Favresse J, Boland L, Schellen M, Fervaille C, Wuestenberghs F, Camboni A, Chatelain B, Mullier F, Defour JP, Jacqmin H. Int J Lab Hematol; 2020 Oct; 42(5):544-551. PubMed ID: 32163671 [Abstract] [Full Text] [Related]
7. Evaluation of cell count and classification capabilities in body fluids using a fully automated Sysmex XN equipped with high-sensitive Analysis (hsA) mode and DI-60 hematology analyzer system. Takemura H, Ai T, Kimura K, Nagasaka K, Takahashi T, Tsuchiya K, Yang H, Konishi A, Uchihashi K, Horii T, Tabe Y, Ohsaka A. PLoS One; 2018 Oct; 13(4):e0195923. PubMed ID: 29698492 [Abstract] [Full Text] [Related]
8. Detection of malignant cells in serous body fluids by counting high-fluorescent cells on the Sysmex XN-2000 hematology analyzer. Labaere D, Boeckx N, Geerts I, Moens M, Van den Driessche M. Int J Lab Hematol; 2015 Oct; 37(5):715-22. PubMed ID: 26074270 [Abstract] [Full Text] [Related]
9. Screening for malignant tumor cells in serous effusions with an automatic hematology analyzer using a novel diagnostic algorithm. Sun D, Mao X, An T, He X, Qiu K, Luo Y, Qin Z, He Y, Xiong T, Feng H, Li J, Zheng L. Ann Transl Med; 2022 Mar; 10(6):321. PubMed ID: 35433938 [Abstract] [Full Text] [Related]
10. Analytical performance of the digital morphology analyzer Sysmex DI-60 for body fluid cell differential counts. Yoon S, Kim HR. PLoS One; 2023 Mar; 18(7):e0288551. PubMed ID: 37498851 [Abstract] [Full Text] [Related]
12. Improving performance of recently introduced flow cytometry-based approach of malignant cell screening in serous cavity effusion. Sun J, Ding S, Zhu L, Liu Y, Jiang Q, Song S, Chen W, Li S, Ma P. Int J Lab Hematol; 2020 Oct; 42(5):612-618. PubMed ID: 32573949 [Abstract] [Full Text] [Related]
14. Validation of reflex testing rules and establishment of a new workflow for body fluid cell analysis using a Sysmex XN-550 automatic hematology analyzer. Cho YU, You E, Jang S, Park CJ. Int J Lab Hematol; 2018 Jun; 40(3):258-267. PubMed ID: 29314650 [Abstract] [Full Text] [Related]
16. Serous body fluid evaluation using the new automated haematology analyser Mindray BC-6800Plus. Boldú L, Laguna J, Casanova A, García S, Molina A, Merino A. Clin Chem Lab Med; 2022 Oct 26; 60(11):1786-1795. PubMed ID: 36039597 [Abstract] [Full Text] [Related]
17. Extent of agreement between the body fluid model of Sysmex XN-20 and the manual microscopy method. Huang WH, Lu LP, Wu K, Guo FY, Guo J, Yu JL, Zhou DY, Sun Y, Deng AM. J Clin Lab Anal; 2017 Sep 26; 31(5):. PubMed ID: 27925284 [Abstract] [Full Text] [Related]
18. Comparison of Sysmex XN-V body fluid mode and deep-learning-based quantification with manual techniques for total nucleated cell count and differential count for equine bronchoalveolar lavage samples. Lapsina S, Riond B, Hofmann-Lehmann R, Stirn M. BMC Vet Res; 2024 Feb 05; 20(1):48. PubMed ID: 38317167 [Abstract] [Full Text] [Related]
19. Evaluation of Sysmex-UF 5000-BF Module for Sterile Body Fluids. An Alternative for Conventional Methods? Baran E, Ilki AA. Clin Lab; 2023 Apr 01; 69(4):. PubMed ID: 37057945 [Abstract] [Full Text] [Related]