These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. [Measurement of cardiac output using localized thoracic electrical plethysmography (correlation study with the dye dilution technic]. Demange J, Pernod J, Haguenauer G, Colin J. Ann Med Interne (Paris); 1972 Dec; 123(12):1019-24. PubMed ID: 4578115 [No Abstract] [Full Text] [Related]
3. [Reliability and effectiveness of monitoring the stroke and minute volume of the heart by Kubicek's rheographic method]. Genin AM, Zingerman LS, Maksimov DG, Belozerov GE, Katuntsev VP. Kosm Biol Aviakosm Med; 1984 Dec; 18(3):9-14. PubMed ID: 6737989 [Abstract] [Full Text] [Related]
4. Development and evaluation of an impedance cardiac output system. Kubicek WG, Karnegis JN, Patterson RP, Witsoe DA, Mattson RH. Aerosp Med; 1966 Dec; 37(12):1208-12. PubMed ID: 5339656 [No Abstract] [Full Text] [Related]
5. [Use of the tetrapolar rheography method for assessment of the circulatory system]. Tikhomirov IB, Turchaninova VF, Selivanenko VT, Staferov VA. Kosm Biol Aviakosm Med; 1977 Dec; 11(4):70-4. PubMed ID: 333176 [Abstract] [Full Text] [Related]
6. [Evaluation of a tetrapolar rheographic method for determining cardiac output in rats]. Ismailov ShI, Baranov VS, Medvedev OS, Matsievskiĭ DD, Suchkov VV. Fiziol Zh SSSR Im I M Sechenova; 1982 Aug; 68(8):1171-4. PubMed ID: 6215267 [No Abstract] [Full Text] [Related]
7. [Comparative evaluation of impedance cardiographic and dye dilution methods in determining hemodynamic indices]. Kaloianova A. Vutr Boles; 1981 Aug; 20(4):93-8. PubMed ID: 7029910 [Abstract] [Full Text] [Related]
8. [Usefulness of ultrasonic blood flow determination after renal artery reconstruction for later prognosis]. Rykowski H, Szczawiński A, Wesołowski J, Nowicki A, Kwietniak Z, Ratynski B, Stawowiak S. Pol Przegl Chir; 1980 Mar; 52(3):217-23. PubMed ID: 7393769 [No Abstract] [Full Text] [Related]
9. [Impedance cardiography and cardiac output]. Mikami T, Miyamoto Y. Rinsho Byori; 1983 Oct; Spec No 57():30-42. PubMed ID: 6371320 [No Abstract] [Full Text] [Related]
10. Evaluation of impedance cardiac output in children. Lababidi Z, Ehmke DA, Durnin RE, Leaverton PE, Lauer RM. Pediatrics; 1971 May; 47(5):870-9. PubMed ID: 4929902 [No Abstract] [Full Text] [Related]
11. [Non-invasive continuous measurement of the cardiac minute-volume by means of impedance]. Ritz R, Baitsch G, Burkart F. Schweiz Med Wochenschr; 1974 Nov 02; 104(44):1589-90. PubMed ID: 4607503 [No Abstract] [Full Text] [Related]
12. Determination of cardiac output in man by means of impedance plethysmography. Harley A, Greenfield JC. Aerosp Med; 1968 Mar 02; 39(3):248-52. PubMed ID: 4865723 [No Abstract] [Full Text] [Related]
13. [Measurement of cardiac output by localized thoracic electrical plethysmography]. Demange J, Pernod J, Haguenauer G, Colin J. Nouv Presse Med; 1972 Dec 16; 1(45):3067-9. PubMed ID: 4567696 [No Abstract] [Full Text] [Related]
14. Comparative evaluation of the thoracic impedance and isotope dilution methods for measuring cardiac output. Judy WV, Langley FM, McCowen KD, Stinnett DM, Baker LE, Johnson PC. Aerosp Med; 1969 May 16; 40(5):532-6. PubMed ID: 4890370 [No Abstract] [Full Text] [Related]
15. Noninvasive monitoring of cardiac output during exercise by inductance cardiography. Kaplan V, Bucklar GB, Bloch KE. Med Sci Sports Exerc; 2003 May 16; 35(5):747-52. PubMed ID: 12750583 [Abstract] [Full Text] [Related]
17. [Intraoperative monitoring with M-mode transesophageal echocardiography; monitoring of the cardiac function by aortic valve echograms]. Suzuki A, Uematsu H, Tanahashi T, Yamamoto M. Masui; 1987 Apr 16; 36(4):549-54. PubMed ID: 3302340 [No Abstract] [Full Text] [Related]
18. [Wider potentials for determining the circulating blood volume in clinical practice]. Shanin SS, Gubin VV. Vestn Khir Im I I Grek; 1985 Dec 16; 135(12):107-10. PubMed ID: 3914133 [Abstract] [Full Text] [Related]
19. [Comparative evaluation between the impedance method and the Fick method for determining cardiac minute volume]. Kotsev P, Grigorov M, Georgiev L, Daskalov I. Vutr Boles; 1980 Dec 16; 19(6):46-9. PubMed ID: 7210652 [Abstract] [Full Text] [Related]
20. [The use of rheography for assessing the adequacy of prolonged artificial ventilation of the lungs in patients undergoing surgery of pulmonary tuberculosis]. Nefedov VB, Dzhunusbekov AD, Tuleshova ES. Probl Tuberk; 1990 Dec 16; (8):34-7. PubMed ID: 2255694 [Abstract] [Full Text] [Related] Page: [Next] [New Search]