These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
202 related items for PubMed ID: 35220611
1. Initial experiences of transapical beating-heart mitral valve repair with a novel artificial chordal implantation device. Wang S, Meng X, Hu S, Sievert H, Xie Y, Hu X, Sun Y, Luo Z, Zhou H, Zhang G, Pan X. J Card Surg; 2022 May; 37(5):1242-1249. PubMed ID: 35220611 [Abstract] [Full Text] [Related]
2. Off-pump transapical implantation of artificial chordae to correct mitral regurgitation: early results of a single-center experience. Rucinskas K, Janusauskas V, Zakarkaite D, Aidietiene S, Samalavicius R, Speziali G, Aidietis A. J Thorac Cardiovasc Surg; 2014 Jan; 147(1):95-9. PubMed ID: 24100100 [Abstract] [Full Text] [Related]
3. Off-pump transapical implantation of artificial neo-chordae to correct mitral regurgitation: the TACT Trial (Transapical Artificial Chordae Tendinae) proof of concept. Seeburger J, Rinaldi M, Nielsen SL, Salizzoni S, Lange R, Schoenburg M, Alfieri O, Borger MA, Mohr FW, Aidietis A. J Am Coll Cardiol; 2014 Mar 11; 63(9):914-9. PubMed ID: 24076529 [Abstract] [Full Text] [Related]
4. Transapical off-pump mitral valve repair. First experience with the NeoChord system in Poland (report of two cases). Wróbel K, Kurnicka K, Zygier M, Dyk W, Wojdyga R, Zieliński D, Jarzębska M, Juraszyński Z, Lichodziejewska B, Pruszczyk P, Biederman A, Speziali G, Kasten U. Kardiol Pol; 2017 Mar 11; 75(1):7-12. PubMed ID: 27714712 [Abstract] [Full Text] [Related]
5. Good 5-Year Durability of Transapical Beating Heart Off-Pump Mitral Valve Repair With Neochordae. Kiefer P, Meier S, Noack T, Borger MA, Ender J, Hoyer A, Mohr FW, Seeburger J. Ann Thorac Surg; 2018 Aug 11; 106(2):440-445. PubMed ID: 29729267 [Abstract] [Full Text] [Related]
6. Anesthetic Management and Procedural Outcomes of Patients Undergoing Off-Pump Transapical Implantation of Artificial Chordae to Correct Mitral Regurgitation: Case Series of 76 Patients. Samalavicius RS, Norkiene I, Drasutiene A, Lipnevicius A, Janusauskas V, Urbonas K, Zakarkaite D, Aidietis A, Rucinskas K. Anesth Analg; 2018 Mar 11; 126(3):776-784. PubMed ID: 29283917 [Abstract] [Full Text] [Related]
7. Transapical Beating-Heart Mitral Valve Repair Using a Novel Artificial Chordae Implantation System. Wang S, Meng X, Luo Z, Pan X. Ann Thorac Surg; 2018 Nov 11; 106(5):e265-e267. PubMed ID: 29890145 [Abstract] [Full Text] [Related]
9. Artificial chordae in the setting of complex mitral valve repair: early outcomes using the folding leaflet technique. García Fuster R, Martín E, Paredes F, Mena A, Cánovas S, Gil O, Hornero F, Martínez J. Interact Cardiovasc Thorac Surg; 2014 May 11; 18(5):586-95. PubMed ID: 24525854 [Abstract] [Full Text] [Related]
18. A 25-year study of chordal replacement with expanded polytetrafluoroethylene in mitral valve repair†. Hata H, Fujita T, Shimahara Y, Sato S, Ishibashi-Ueda H, Kobayashi J. Interact Cardiovasc Thorac Surg; 2015 Apr 11; 20(4):463-8; discussion 468. PubMed ID: 25547921 [Abstract] [Full Text] [Related]
19. Feasibility of anterior mitral leaflet flail repair with transapical beating-heart neochord implantation. Colli A, Manzan E, Zucchetta F, Sarais C, Pittarello D, Gerosa G. JACC Cardiovasc Interv; 2014 Nov 11; 7(11):1320-1. PubMed ID: 25326735 [No Abstract] [Full Text] [Related]