21. Transcutaneous versus Total Serum Bilirubin Measurements in Preterm Infants. Jegathesan T, Campbell DM, Ray JG, Shah V, Berger H, Hayeems RZ, Sgro M, NeoHBC. Neonatology; 2021; 118(4):443-453. PubMed ID: 34139689 [Abstract] [Full Text] [Related]
22. Patched Skin Bilirubin Assay to Monitor Neonates Born Extremely Preterm Undergoing Phototherapy. De Luca D, Dell'Orto V. J Pediatr; 2017 Sep; 188():122-127. PubMed ID: 28662949 [Abstract] [Full Text] [Related]
23. Transcutaneous bilirubin measured on protected skin during phototherapy in term and preterm neonates. İşleyen F, Çelik İH, Demirel N, Erçel NÖ, Işık DU, Baş AY. Early Hum Dev; 2023 Oct; 185():105858. PubMed ID: 37722208 [Abstract] [Full Text] [Related]
24. Differences Between Transcutaneous and Serum Bilirubin Measurements in Black African Neonates. Olusanya BO, Imosemi DO, Emokpae AA. Pediatrics; 2016 Sep; 138(3):. PubMed ID: 27577578 [Abstract] [Full Text] [Related]
26. Correlation between transcutaneous and serum bilirubin in preterm infants before, during, and after phototherapy. Cucuy M, Juster-Reicher A, Flidel O, Shinwell E. J Matern Fetal Neonatal Med; 2018 May 10; 31(10):1323-1326. PubMed ID: 28372516 [Abstract] [Full Text] [Related]
34. A new transcutaneous bilirubinometer, BiliCheck, used in the neonatal intensive care unit and the maternity ward. Ebbesen F, Rasmussen LM, Wimberley PD. Acta Paediatr; 2002 May 10; 91(2):203-11. PubMed ID: 11952010 [Abstract] [Full Text] [Related]
35. The Impact of Phototherapy on the Accuracy of Transcutaneous Bilirubin Measurements in Neonates: Optimal Measurement Site and Timing. Ho SR, Lin YC, Chen CN. Diagnostics (Basel); 2021 Sep 20; 11(9):. PubMed ID: 34574069 [Abstract] [Full Text] [Related]
37. The accuracy of transcutaneous bilirubinometer measurements to identify the hyperbilirubinemia in outpatient newborn population. Ercan Ş, Özgün G. Clin Biochem; 2018 May 20; 55():69-74. PubMed ID: 29601801 [Abstract] [Full Text] [Related]
39. Discrepancies between transcutaneous and serum bilirubin measurements. Taylor JA, Burgos AE, Flaherman V, Chung EK, Simpson EA, Goyal NK, Von Kohorn I, Dhepyasuwan N, Better Outcomes through Research for Newborns Network. Pediatrics; 2015 Feb 20; 135(2):224-31. PubMed ID: 25601981 [Abstract] [Full Text] [Related]