These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
124 related items for PubMed ID: 35443592
21. Anti-doping analytes in serum: A comparison of SST and SST-II Advance blood collection tubes. Miller GD, Cox HD, Nair V, Eichner D. Drug Test Anal; 2019 Jul; 11(7):931-936. PubMed ID: 30901507 [Abstract] [Full Text] [Related]
24. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube. Arslan FD, Karakoyun I, Basok BI, Aksit MZ, Baysoy A, Ozturk YK, Guclu YA, Duman C. Biochem Med (Zagreb); 2017 Oct 15; 27(3):030706. PubMed ID: 28900369 [Abstract] [Full Text] [Related]
28. Test results comparison and sample stability study: is the BD Barricor tube a suitable replacement for the BD RST tube? Mandić S, Mandić D, Lukić I, Rolić T, Horvat V, Lukić M, Osvald S, Šerić V. Biochem Med (Zagreb); 2020 Oct 15; 30(3):030704. PubMed ID: 33071555 [Abstract] [Full Text] [Related]
29. Evaluation of the BD Vacutainer PST II blood collection tube for special chemistry analytes. Chance J, Berube J, Vandersmissen M, Blanckaert N. Clin Chem Lab Med; 2009 Oct 15; 47(3):358-61. PubMed ID: 19676149 [Abstract] [Full Text] [Related]
30. Biochemical, immunochemical and serology analytes validation of the lithium heparin BD Barricor blood collection tube on a highly automated Roche COBAS8000 instrument. Ferrari D, Strollo M, Vidali M, Motta A, Pontillo M, Locatelli M. Acta Biomed; 2020 Mar 19; 91(1):47-55. PubMed ID: 32191654 [Abstract] [Full Text] [Related]
31. Influence of blood collection systems on the prothrombin time and international sensitivity index determined with human and rabbit thromboplastin reagents. van den Besselaar AM, Hoekstra MM, Witteveen E, Didden JH, van der Meer FJ. Am J Clin Pathol; 2007 May 19; 127(5):724-9. PubMed ID: 17439830 [Abstract] [Full Text] [Related]
32. Recentrifugation of Lithium Heparin Gel Separator Tubes up to 8 h after Blood Collection Has No Relevant Influence on the Stability of 30 Routine Biochemical Analytes. van Balveren JA, Gemen EFA, Kusters R. J Appl Lab Med; 2019 Mar 19; 3(5):864-869. PubMed ID: 31639761 [Abstract] [Full Text] [Related]
33. Comparison of plastic vs. glass evacuated serum-separator (SST) blood-drawing tubes for common clinical chemistry determinations. Hill BM, Laessig RH, Koch DD, Hassemer DJ. Clin Chem; 1992 Aug 19; 38(8 Pt 1):1474-8. PubMed ID: 1643717 [Abstract] [Full Text] [Related]
35. Comparison of Improvacuter™ tubes with BD Vacutainer™ tubes for various hormones in the aspects of stability and influence of gel separators. Zungun C, Yılmaz FM, Boru EG, Topcuoglu C. Clin Chem Lab Med; 2015 Feb 19; 53(2):231-8. PubMed ID: 25153600 [Abstract] [Full Text] [Related]
36. Comparison of the effect of gel used in two different serum separator tubes for thyroid function tests. Ercan M, Fırat Oğuz E, Akbulut ED, Yilmaz M, Turhan T. J Clin Lab Anal; 2018 Jul 19; 32(6):e22427. PubMed ID: 29512190 [Abstract] [Full Text] [Related]
37. Evaluation of serum and rapid serum separator collection tubes for therapeutic drug assays. Garza KY, Carter J, Mercer A, Jarrar P, Martin J, Daughtry S, Mahomes A, Knezevic CE. Clin Biochem; 2023 May 19; 115():81-85. PubMed ID: 36027943 [Abstract] [Full Text] [Related]
38. Test results comparison: is the S-Monovette® Lithium-Heparin Gel+ a suitable replacement for the S-Monovette® Lithium-Heparin Gel on Alinity Abbott®? Ghali S, Etienne C, Bérénice O, Romy G. Clin Chem Lab Med; 2023 Jul 26; 61(8):e148-e151. PubMed ID: 36848494 [No Abstract] [Full Text] [Related]