These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
132 related items for PubMed ID: 35723048
1. Inversion-Recovery-Prepared Oscillating Gradient Sequence Improves Diffusion-Time Dependency Measurements in the Human Brain. Li H, Zu T, Hsu YC, Zhao Z, Liu R, Zheng T, Li Q, Sun Y, Liu D, Zhang J, Zhang Y, Wu D. J Magn Reson Imaging; 2023 Feb; 57(2):446-453. PubMed ID: 35723048 [Abstract] [Full Text] [Related]
2. Diffusion-prepared 3D gradient spin-echo sequence for improved oscillating gradient diffusion MRI. Wu D, Liu D, Hsu YC, Li H, Sun Y, Qin Q, Zhang Y. Magn Reson Med; 2021 Jan; 85(1):78-88. PubMed ID: 32643240 [Abstract] [Full Text] [Related]
3. Feasibility of oscillating and pulsed gradient diffusion MRI to assess neonatal hypoxia-ischemia on clinical systems. Gao F, Shen X, Zhang H, Ba R, Ma X, Lai C, Zhang J, Zhang Y, Wu D. J Cereb Blood Flow Metab; 2021 Jun; 41(6):1240-1250. PubMed ID: 32811261 [Abstract] [Full Text] [Related]
4. Histological and molecular classifications of pediatric glioma with time-dependent diffusion MRI-based microstructural mapping. Zhang H, Liu K, Ba R, Zhang Z, Zhang Y, Chen Y, Gu W, Shen Z, Shu Q, Fu J, Wu D. Neuro Oncol; 2023 Jun 02; 25(6):1146-1156. PubMed ID: 36617263 [Abstract] [Full Text] [Related]
8. Distortion-free imaging: A double encoding method (DIADEM) combined with multiband imaging for rapid distortion-free high-resolution diffusion imaging on a compact 3T with high-performance gradients. In MH, Tan ET, Trzasko JD, Shu Y, Kang D, Yarach U, Tao S, Gray EM, Huston J, Bernstein MA. J Magn Reson Imaging; 2020 Jan 02; 51(1):296-310. PubMed ID: 31111581 [Abstract] [Full Text] [Related]
9. Oscillating gradient diffusion MRI reveals unique microstructural information in normal and hypoxia-ischemia injured mouse brains. Wu D, Martin LJ, Northington FJ, Zhang J. Magn Reson Med; 2014 Nov 02; 72(5):1366-74. PubMed ID: 25168861 [Abstract] [Full Text] [Related]
10. Oscillating-gradient diffusion magnetic resonance imaging detects acute subcellular structural changes in the mouse forebrain after neonatal hypoxia-ischemia. Wu D, Martin LJ, Northington FJ, Zhang J. J Cereb Blood Flow Metab; 2019 Jul 02; 39(7):1336-1348. PubMed ID: 29436246 [Abstract] [Full Text] [Related]
11. Diffusion-time dependence of diffusional kurtosis in the mouse brain. Aggarwal M, Smith MD, Calabresi PA. Magn Reson Med; 2020 Sep 02; 84(3):1564-1578. PubMed ID: 32022313 [Abstract] [Full Text] [Related]
14. Time-dependent diffusion MRI to distinguish malignant from benign head and neck tumors. Iima M, Yamamoto A, Kataoka M, Yamada Y, Omori K, Feiweier T, Togashi K. J Magn Reson Imaging; 2019 Jul 02; 50(1):88-95. PubMed ID: 30578563 [Abstract] [Full Text] [Related]
15. Frequency-dependent diffusion kurtosis imaging in the human brain using an oscillating gradient spin echo sequence and a high-performance head-only gradient. Dai E, Zhu A, Yang GK, Quah K, Tan ET, Fiveland E, Foo TKF, McNab JA. Neuroimage; 2023 Oct 01; 279():120328. PubMed ID: 37586445 [Abstract] [Full Text] [Related]
16. Choroid plexus cysts analyzed using diffusion-weighted imaging with short diffusion-time. Maekawa T, Hori M, Murata K, Feiweier T, Andica C, Fukunaga I, Koshino S, Hagiwara A, Kamiya K, Kamagata K, Wada A, Abe O, Aoki S. Magn Reson Imaging; 2019 Apr 01; 57():323-327. PubMed ID: 30605722 [Abstract] [Full Text] [Related]
17. Imaging neurodegeneration in the mouse hippocampus after neonatal hypoxia-ischemia using oscillating gradient diffusion MRI. Aggarwal M, Burnsed J, Martin LJ, Northington FJ, Zhang J. Magn Reson Med; 2014 Sep 01; 72(3):829-40. PubMed ID: 24123409 [Abstract] [Full Text] [Related]
18. Probing mouse brain microstructure using oscillating gradient diffusion MRI. Aggarwal M, Jones MV, Calabresi PA, Mori S, Zhang J. Magn Reson Med; 2012 Jan 01; 67(1):98-109. PubMed ID: 21590726 [Abstract] [Full Text] [Related]
19. Comparison of pulsed and oscillating gradient diffusion-weighted MRI for characterizing hepatocellular nodules in liver cirrhosis: ex vivo study in a rat model. Wagner M, Doblas S, Poté N, Lambert SA, Ronot M, Garteiser P, Paradis V, Vilgrain V, Van Beers BE. J Magn Reson Imaging; 2020 Apr 01; 51(4):1065-1074. PubMed ID: 31507025 [Abstract] [Full Text] [Related]
20. Inversion-recovery echo-planar MR in adult brain neoplasia. Sheppard S, Davis PC, Kater G, Peterson JE. AJNR Am J Neuroradiol; 1998 Feb 01; 19(2):267-73. PubMed ID: 9504476 [Abstract] [Full Text] [Related] Page: [Next] [New Search]