These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
163 related items for PubMed ID: 36575023
1. Development of a Novel Positive Pressure Protective Suit for a Biosafety Level 4 Laboratory in Japan. Shichinohe S, Sakurai Y, Hayasaka D, Yamada E, Shinohara K, Kurosaki Y, Nakajima K. Jpn J Infect Dis; 2023 Mar 24; 76(2):162-166. PubMed ID: 36575023 [Abstract] [Full Text] [Related]
2. [Development of a positive pressure protective suit for BSL-4 laboratory]. Shichinohe S. Uirusu; 2022 Mar 24; 72(2):131-138. PubMed ID: 38220157 [Abstract] [Full Text] [Related]
3. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 1. Biosafety Level 4 Suit Laboratory Suite Entry and Exit Procedures. Janosko K, Holbrook MR, Adams R, Barr J, Bollinger L, Newton JT, Ntiforo C, Coe L, Wada J, Pusl D, Jahrling PB, Kuhn JH, Lackemeyer MG. J Vis Exp; 2016 Oct 03; (116):. PubMed ID: 27768063 [Abstract] [Full Text] [Related]
4. Maintaining differential pressure gradients does not increase safety inside modern BSL-4 laboratories. Kurth A, Weber U, Reichenbacher D. Front Bioeng Biotechnol; 2022 Oct 03; 10():953675. PubMed ID: 36110311 [Abstract] [Full Text] [Related]
5. Efficacy Testing of Personal Protective Filters on Biosafety Level 4 Positive Pressure Suits. Fey G, Leung A, Landry L, Lightly G, Kasloff S, Cutts T, Krishnan J. Appl Biosaf; 2021 Jun 01; 26(2):66-70. PubMed ID: 36034692 [Abstract] [Full Text] [Related]
6. Evaluation of the operator protection factors offered by positive pressure air suits against airborne microbiological challenge. Steward JA, Lever MS. Viruses; 2012 Aug 01; 4(8):1202-11. PubMed ID: 23012620 [Abstract] [Full Text] [Related]
7. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 2. General Practices. Mazur S, Holbrook MR, Burdette T, Joselyn N, Barr J, Pusl D, Bollinger L, Coe L, Jahrling PB, Lackemeyer MG, Wada J, Kuhn JH, Janosko K. J Vis Exp; 2016 Oct 03; (116):. PubMed ID: 27768081 [Abstract] [Full Text] [Related]
8. Smart Card Decontamination in a High-Containment Laboratory. Gabbert LR, Smith JD, Neilan JG, Ferman GS, Rasmussen MV. Health Secur; 2018 Oct 03; 16(4):244-251. PubMed ID: 30096256 [Abstract] [Full Text] [Related]
9. Establishment of Biosafety Level-3 (BSL-3) laboratory: important criteria to consider while designing, constructing, commissioning & operating the facility in Indian setting. Mourya DT, Yadav PD, Majumdar TD, Chauhan DS, Katoch VM. Indian J Med Res; 2014 Aug 03; 140(2):171-83. PubMed ID: 25297350 [Abstract] [Full Text] [Related]
10. [Developing a Biosafety Level 4 Laboratory user training program]. Nanbo A, Urata S, Tsuda Y. Uirusu; 2022 Aug 03; 72(2):125-130. PubMed ID: 38220156 [Abstract] [Full Text] [Related]
11. Assessment of biorisk management systems in high containment laboratories, 18 countries in Europe, 2016 and 2017. Appelt S, Jacob D, Rohleder AM, Bråve A, Szekely Björndal Å, Di Caro A, Grunow R, Joint Action EMERGE laboratory networkThe EMERGE partners are acknowledged at the end of the article.. Euro Surveill; 2020 Sep 03; 25(36):. PubMed ID: 32914748 [Abstract] [Full Text] [Related]
12. Practical biosafety in the tuberculosis laboratory: containment at the source is what truly counts. van Soolingen D, Wisselink HJ, Lumb R, Anthony R, van der Zanden A, Gilpin C. Int J Tuberc Lung Dis; 2014 Aug 03; 18(8):885-9. PubMed ID: 25199000 [Abstract] [Full Text] [Related]
13. Standard practice for cell sorting in a BSL-3 facility. Perfetto SP, Ambrozak DR, Nguyen R, Roederer M, Koup RA, Holmes KL. Methods Mol Biol; 2011 Aug 03; 699():449-69. PubMed ID: 21116997 [Abstract] [Full Text] [Related]
14. Biorisk Management for SARS-CoV-2 Research in a Biosafety Level-3 Core Facility. Joseph T, Phyu S, Se-Thoe SY, Chu JJH. Methods Mol Biol; 2022 Aug 03; 2452():441-464. PubMed ID: 35554920 [Abstract] [Full Text] [Related]
15. Certification & validation of biosafety level-2 & biosafety level-3 laboratories in Indian settings & common issues. Mourya DT, Yadav PD, Khare A, Khan AH. Indian J Med Res; 2017 Oct 03; 146(4):459-467. PubMed ID: 29434059 [Abstract] [Full Text] [Related]
16. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 3. Aerobiology. Bohannon JK, Janosko K, Holbrook MR, Barr J, Pusl D, Bollinger L, Coe L, Hensley LE, Jahrling PB, Wada J, Kuhn JH, Lackemeyer MG. J Vis Exp; 2016 Oct 03; (116):. PubMed ID: 27768036 [Abstract] [Full Text] [Related]
17. Biosafety Level 4 Laboratory User Training Program, China. Xia H, Huang Y, Ma H, Liu B, Xie W, Song D, Yuan Z. Emerg Infect Dis; 2019 May 03; 25(5):. PubMed ID: 31002302 [Abstract] [Full Text] [Related]
18. Guidelines for Biosafety Training Programs for Workers Assigned to BSL-3 Research Laboratories. Homer LC, Alderman TS, Blair HA, Brocard AS, Broussard EE, Ellis RP, Frerotte J, Low EW, McCarthy TR, McCormick JM, Newton JM, Rogers FC, Schlimgen R, Stabenow JM, Stedman D, Warfield C, Ntiforo CA, Whetstone CT, Zimmerman D, Barkley E. Biosecur Bioterror; 2013 Mar 03; 11(1):10-9. PubMed ID: 23477631 [Abstract] [Full Text] [Related]
19. Biosafety level 3 laboratory for autopsies of patients with severe acute respiratory syndrome: principles, practices, and prospects. Li L, Gu J, Shi X, Gong E, Li X, Shao H, Shi X, Jiang H, Gao X, Cheng D, Guo L, Wang H, Shi X, Wang P, Zhang Q, Shen B. Clin Infect Dis; 2005 Sep 15; 41(6):815-21. PubMed ID: 16107979 [Abstract] [Full Text] [Related]
20. The hidden face of academic researches on classified highly pathogenic microorganisms. Devaux CA. Infect Genet Evol; 2015 Jan 15; 29():26-34. PubMed ID: 25445654 [Abstract] [Full Text] [Related] Page: [Next] [New Search]