These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


197 related items for PubMed ID: 36763854

  • 1.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 2.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 3. An asymmetrical whole-body birdcage RF coil without RF shield for hyperpolarized 129 Xe lung MR imaging at 1.5 T.
    Puddu C, Rao M, Xu X, Deppe MH, Collier G, Maunder A, Chan HF, De Zanche N, Robb F, Wild JM.
    Magn Reson Med; 2021 Dec; 86(6):3373-3381. PubMed ID: 34268802
    [Abstract] [Full Text] [Related]

  • 4. Monopole antenna array design for 3 T and 7 T magnetic resonance imaging.
    Kausar ASMZ, Reutens DC, Weber E, Vegh V.
    PLoS One; 2019 Dec; 14(4):e0214637. PubMed ID: 30933999
    [Abstract] [Full Text] [Related]

  • 5. RF coil that minimizes electronic components while enhancing performance for rodent MRI at 7 Tesla.
    Vazquez F, Villareal A, Lazovic J, Martin R, Solis-Najera SE, Rodriguez AO.
    Biomed Phys Eng Express; 2024 Sep 03; 10(5):. PubMed ID: 39173647
    [Abstract] [Full Text] [Related]

  • 6. An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T.
    Kraff O, Bitz AK, Dammann P, Ladd SC, Ladd ME, Quick HH.
    Med Phys; 2010 Dec 03; 37(12):6368-76. PubMed ID: 21302794
    [Abstract] [Full Text] [Related]

  • 7. An essentially radiation-transparent body coil integrated with a patient rotation system for MR-guided particle therapy.
    Dietrich KA, Klüter S, Dinkel F, Echner G, Brons S, Orzada S, Debus J, Ladd ME, Platt T.
    Med Phys; 2024 Jun 03; 51(6):4028-4043. PubMed ID: 38656549
    [Abstract] [Full Text] [Related]

  • 8. ICE decoupling technique for RF coil array designs.
    Li Y, Xie Z, Pang Y, Vigneron D, Zhang X.
    Med Phys; 2011 Jul 03; 38(7):4086-93. PubMed ID: 21859008
    [Abstract] [Full Text] [Related]

  • 9. Study on the radiofrequency transparency of electrically floating and ground PET inserts in a 3 T clinical MRI system.
    Akram MSH, Obata T, Nishikido F, Yamaya T.
    Med Phys; 2022 May 03; 49(5):2965-2978. PubMed ID: 35271749
    [Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11. Comparison of RF body coils for MRI at 3  T: a simulation study using parallel transmission on various anatomical targets.
    Wu X, Zhang X, Tian J, Schmitter S, Hanna B, Strupp J, Pfeuffer J, Hamm M, Wang D, Nistler J, He B, Vaughan TJ, Ugurbil K, Van de Moortele PF.
    NMR Biomed; 2015 Oct 03; 28(10):1332-44. PubMed ID: 26332290
    [Abstract] [Full Text] [Related]

  • 12. A 16-Channel Dipole Antenna Array for Human Head Magnetic Resonance Imaging at 10.5 Tesla.
    Woo MK, DelaBarre L, Waks M, Radder J, Choi US, Lagore R, Ugurbil K, Adriany G.
    Sensors (Basel); 2021 Oct 30; 21(21):. PubMed ID: 34770558
    [Abstract] [Full Text] [Related]

  • 13. Comparison of birdcage and phase array coil using FDTD for the B(1) homogeneity in high field MRI.
    Seo JH, Heo HY, Han BH, Lee SY.
    Annu Int Conf IEEE Eng Med Biol Soc; 2007 Oct 30; 2007():3902-5. PubMed ID: 18002852
    [Abstract] [Full Text] [Related]

  • 14.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 15. Microstrip Transmission Line RF Coil for a PET/MRI Insert.
    Akram MSH, Obata T, Yamaya T.
    Magn Reson Med Sci; 2020 May 01; 19(2):147-153. PubMed ID: 31776297
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17. Numerical and Workbench Design of 2.35 T Double-Tuned (¹H/²³Na) Nested RF Birdcage Coils Suitable for Animal Size MRI.
    Fantasia M, Galante A, Maggiorelli F, Retico A, Fontana N, Monorchio A, Alecci M.
    IEEE Trans Med Imaging; 2020 Oct 01; 39(10):3175-3186. PubMed ID: 32310762
    [Abstract] [Full Text] [Related]

  • 18. Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging.
    Seo JH, Ryu Y, Chung JY.
    Sensors (Basel); 2022 Jun 03; 22(11):. PubMed ID: 35684895
    [Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 10.