These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


348 related items for PubMed ID: 36907664

  • 1. Depth-of-interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual-ended signal readout.
    Seo M, Park H, Lee S, Ko GB, Lee JS.
    Med Phys; 2023 Jul; 50(7):4112-4121. PubMed ID: 36907664
    [Abstract] [Full Text] [Related]

  • 2. A novel depth-of-interaction block detector for positron emission tomography using a dichotomous orthogonal symmetry decoding concept.
    Zhang Y, Yan H, Baghaei H, Wong WH.
    Phys Med Biol; 2016 Feb 21; 61(4):1608-33. PubMed ID: 26836144
    [Abstract] [Full Text] [Related]

  • 3. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs.
    Kuang Z, Sang Z, Wang X, Fu X, Ren N, Zhang X, Zheng Y, Yang Q, Hu Z, Du J, Liang D, Liu X, Zheng H, Yang Y.
    Med Phys; 2018 Feb 21; 45(2):613-621. PubMed ID: 29222959
    [Abstract] [Full Text] [Related]

  • 4. Crystal surface and reflector optimization for the SiPM-based dual-ended readout TOF-DOI PET detector.
    Kang HG, Yamaya T, Han YB, Song SH, Ko GB, Lee JS, Hong SJ.
    Biomed Phys Eng Express; 2020 Nov 04; 6(6):. PubMed ID: 34035192
    [Abstract] [Full Text] [Related]

  • 5. High resolution detectors for whole-body PET scanners by using dual-ended readout.
    Liu Z, Niu M, Kuang Z, Ren N, Wu S, Cong L, Wang X, Sang Z, Williams C, Yang Y.
    EJNMMI Phys; 2022 Apr 21; 9(1):29. PubMed ID: 35445890
    [Abstract] [Full Text] [Related]

  • 6. Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET.
    Yeom JY, Vinke R, Levin CS.
    Med Phys; 2014 Dec 21; 41(12):122501. PubMed ID: 25471979
    [Abstract] [Full Text] [Related]

  • 7. Depth-encoding using optical photon TOF in a prism-PET detector with tapered crystals.
    Zeng X, LaBella A, Wang Z, Li Y, Tan W, Goldan AH.
    Med Phys; 2024 Jun 21; 51(6):4044-4055. PubMed ID: 38682574
    [Abstract] [Full Text] [Related]

  • 8. Performance of long rectangular semi-monolithic scintillator PET detectors.
    Zhang X, Wang X, Ren N, Hu B, Ding B, Kuang Z, Wu S, Sang Z, Hu Z, Du J, Liang D, Liu X, Zheng H, Yang Y.
    Med Phys; 2019 Apr 21; 46(4):1608-1619. PubMed ID: 30723932
    [Abstract] [Full Text] [Related]

  • 9. High-resolution time-of-flight PET detector with 100 ps coincidence time resolution using a side-coupled phoswich configuration.
    Lee MS, Cates JW, Gonzalez-Montoro A, Levin CS.
    Phys Med Biol; 2021 Jun 09; 66(12):. PubMed ID: 34106089
    [Abstract] [Full Text] [Related]

  • 10. Pushing the limit of BGO-based dual-ended Cherenkov PET detectors through photon transit time correction.
    Yi M, Ko GB, Lee JS.
    Phys Med Biol; 2024 Jan 05; 69(2):. PubMed ID: 38091614
    [Abstract] [Full Text] [Related]

  • 11. An edge-readout, multilayer detector for positron emission tomography.
    Li X, Ruiz-Gonzalez M, Furenlid LR.
    Med Phys; 2018 Jun 05; 45(6):2425-2438. PubMed ID: 29635734
    [Abstract] [Full Text] [Related]

  • 12. SiPM signal readout for inter-crystal scatter event identification in PET detectors.
    Park H, Lee JS.
    Phys Med Biol; 2020 Oct 21; 65(20):205010. PubMed ID: 32702670
    [Abstract] [Full Text] [Related]

  • 13. A novel, SiPM-array-based, monolithic scintillator detector for PET.
    Schaart DR, van Dam HT, Seifert S, Vinke R, Dendooven P, Löhner H, Beekman FJ.
    Phys Med Biol; 2009 Jun 07; 54(11):3501-12. PubMed ID: 19443953
    [Abstract] [Full Text] [Related]

  • 14. A depth encoding PET detector using four-crystals-to-one-SiPM coupling and light-sharing window method.
    Zhang X, Xie S, Yang J, Weng F, Xu J, Huang Q, Peng Q.
    Med Phys; 2019 Aug 07; 46(8):3385-3398. PubMed ID: 31107969
    [Abstract] [Full Text] [Related]

  • 15. A depth-of-interaction encoding PET detector module with dual-ended readout using large-area silicon photomultiplier arrays.
    Du J, Bai X, Cherry SR.
    Phys Med Biol; 2018 Dec 14; 63(24):245019. PubMed ID: 30523925
    [Abstract] [Full Text] [Related]

  • 16. Experimental time resolution limits of modern SiPMs and TOF-PET detectors exploring different scintillators and Cherenkov emission.
    Gundacker S, Martinez Turtos R, Kratochwil N, Pots RH, Paganoni M, Lecoq P, Auffray E.
    Phys Med Biol; 2020 Jan 17; 65(2):025001. PubMed ID: 31851947
    [Abstract] [Full Text] [Related]

  • 17. Evaluation of dual-ended readout GAGG-based DOI-PET detectors with different surface treatments.
    Choghadi MA, Huang SC, Shimazoe K, Takahashi H.
    Med Phys; 2021 Jul 17; 48(7):3470-3478. PubMed ID: 33826779
    [Abstract] [Full Text] [Related]

  • 18. Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET.
    Cates JW, Choong WS, Brubaker E.
    Phys Med Biol; 2024 Feb 13; 69(4):. PubMed ID: 38252971
    [Abstract] [Full Text] [Related]

  • 19. A thick semi-monolithic scintillator detector for clinical PET scanners.
    Zhang C, Wang X, Sun M, Kuang Z, Zhang X, Ren N, Wu S, Sang Z, Sun T, Hu Z, Yang Y, Liu Z.
    Phys Med Biol; 2021 Mar 12; 66(6):065023. PubMed ID: 33709958
    [Abstract] [Full Text] [Related]

  • 20. Performance of a SiPM based semi-monolithic scintillator PET detector.
    Zhang X, Wang X, Ren N, Kuang Z, Deng X, Fu X, Wu S, Sang Z, Hu Z, Liang D, Liu X, Zheng H, Yang Y.
    Phys Med Biol; 2017 Sep 21; 62(19):7889-7904. PubMed ID: 28858853
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 18.