These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
111 related items for PubMed ID: 37019687
1. Analytical performance evaluation of two automated urine sediment analysers using two levels of commercially available quality control material. Hokamp JA, Freeman K, Harr KE. J Small Anim Pract; 2023 Jul; 64(7):442-451. PubMed ID: 37019687 [Abstract] [Full Text] [Related]
2. Analytical performance evaluation of two automated urine chemistry analysers using two levels of commercially available quality control material. Hokamp JA, Freeman K, Harr KE. J Small Anim Pract; 2023 Jul; 64(7):452-462. PubMed ID: 37129019 [Abstract] [Full Text] [Related]
3. Comparison of IDEXX SediVue Dx® urine sediment analyzer to manual microscopy for detection of casts in canine urine. Vasilatis DM, Cowgill LD, Farace G, Peterson S, Yerramilli M, Owens SD. J Vet Intern Med; 2021 May; 35(3):1439-1447. PubMed ID: 33760275 [Abstract] [Full Text] [Related]
4. Accuracy of the IDEXX SediVue Dx analyzer for quantifying RBC and WBC indices in the urine sediments of cats and dogs compared with manual microscopic evaluations. Blanco AE, Heseltine JC, Hernandez AM, Bilbrough GEA, DeNicola DB, Myrick C, Edwards S, Hammond JM, Myers AN, Nabity MB. Vet Clin Pathol; 2022 Dec; 51(4):470-479. PubMed ID: 35596524 [Abstract] [Full Text] [Related]
6. Comparison of the Anvajo Vet Fluidlab 1 urine sediment analyzer to manual microscopy and Idexx SediVue analysis for analysis of urine samples from cats and dogs. Seigner S, Bogedale K, Dorsch R, Zablotski Y, Weber K. J Vet Diagn Invest; 2022 Nov; 34(6):944-954. PubMed ID: 36113155 [Abstract] [Full Text] [Related]
12. Escherichia coli spheroplasts in a Croatian patient misclassified by two urine sediment analysers as erythrocytes: case report. Nikler A, Radišić Biljak V, Čičak H, Marić N, Bejuk D, Poloni JAT, Simundic AM. Biochem Med (Zagreb); 2019 Oct 15; 29(3):030801. PubMed ID: 31624465 [Abstract] [Full Text] [Related]
14. Urine sediment examination: a comparison between the manual method and the iQ200 automated urine microscopy analyzer. Lamchiagdhase P, Preechaborisutkul K, Lomsomboon P, Srisuchart P, Tantiniti P, Khan-u-Ra N, Preechaborisutkul B. Clin Chim Acta; 2005 Aug 15; 358(1-2):167-74. PubMed ID: 16018883 [Abstract] [Full Text] [Related]
15. Evaluation of the Atellica® UAS 800: a new member of the automated urine sediment analyzer family. Aper SJA, Gijzen K, Luimstra JJ, van der Valk JTMH, Russcher A, Koçer RG, Liesting EC, Jacobs LHJ, Lentjes EGWM, Demir AY. Scand J Clin Lab Invest; 2021 Nov 15; 81(7):585-592. PubMed ID: 34686074 [Abstract] [Full Text] [Related]