These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
147 related items for PubMed ID: 3702181
1. [Clinical application of left ventricular assist device]. Sakamoto T, Arai H, Khim BC, Suzuki A, Imachi H, Fujimasa I, Atsumi K. Kyobu Geka; 1986 Mar; 39(3):213-9. PubMed ID: 3702181 [No Abstract] [Full Text] [Related]
2. [Post-myocardial infarction ventricular aneurysm and intractable ventricular tachycardia supported by left ventricular assist device: a case report]. Ueno K, Konishi T, Fukata M, Okura K, Furukawa H, Shiba Y, Yumoto K, Tamaki T, Nogami A, Kato K. J Cardiol; 2004 May; 43(5):231-5. PubMed ID: 15188610 [Abstract] [Full Text] [Related]
3. [Limitation of IABP and application of ventricular assist device in treatment of profound heart failure]. Nakatani T, Takano H, Kumon K, Fujita T. Kyobu Geka; 1986 Mar; 39(3):192-7. PubMed ID: 3702178 [No Abstract] [Full Text] [Related]
4. [Intraaortic balloon pumping--current status of IABP and artificial heart in Japan]. Okada M, Nakamura K. Kyobu Geka; 1986 Mar; 39(3):172-81. PubMed ID: 3517438 [No Abstract] [Full Text] [Related]
5. [Percutaneous insertion of a left ventricular assist device for cardiogenic shock in a patient with a myocardial infarction]. Ottervanger JP, de Feijter P, Gardien M, Serruys PW. Ned Tijdschr Geneeskd; 2003 Jan 25; 147(4):164-6. PubMed ID: 12635549 [Abstract] [Full Text] [Related]
6. [A case report of clinical application of left ventricular assist device for a profound left ventricular heart failure after open heart surgery]. Nishiwaki N, Nishizawa J, Matsumoto M, Konishi Y, Kobayashi T, Watanabe R, Nishimura K. Nihon Geka Hokan; 1988 Sep 01; 57(5):413-20. PubMed ID: 3266955 [No Abstract] [Full Text] [Related]
7. [A case of critical postoperative myocardial infarction successfully resuscitated by combination of IABP and r-heart bypass assist]. Miyata Y, Ishihara T, Ohmiya T, Tamaki S, Tajima K, Maseki T, Sugimura S. Kyobu Geka; 1983 Feb 01; 36(2):115-8. PubMed ID: 6601735 [No Abstract] [Full Text] [Related]
8. [A case of acute right ventricular infarction and life-saving right ventricular assistance following emergency coronary revascularization and resection of a left ventricular aneurysm--discussion of indication and proper assist flow volume]. Fukuchi T, Ohkawa Y, Koike S, Kubo K, Murase K. Nihon Kyobu Geka Gakkai Zasshi; 1992 Sep 01; 40(9):1767-72. PubMed ID: 1402198 [Abstract] [Full Text] [Related]
9. Successful use of left ventricular assist device for primary graft failure after heart transplantation. Hooper TL, Odom NJ, Fetherston GJ, Waterhouse P, Hilton CJ, Dark JH. J Heart Transplant; 1988 Sep 01; 7(5):385-7. PubMed ID: 3058909 [Abstract] [Full Text] [Related]
10. [Care and mechanical cardiac support for severe heart failure associating acute myocardial infarction and open heart surgery]. Nihon Kyobu Geka Gakkai Zasshi; 1992 May 01; 40(5):698-713. PubMed ID: 1629648 [No Abstract] [Full Text] [Related]
11. Control of postinfarction ventricular irritability with the intraaortic balloon pump. Hanson EC, Levine FH, Kay HR, Leinbach RC, Gold HK, Daggett WM, Austen WG, Buckley MJ. Circulation; 1980 Aug 01; 62(2 Pt 2):I130-7. PubMed ID: 7397988 [No Abstract] [Full Text] [Related]
12. [Left ventricular assist devices in the catheterisation laboratory]. Boughalem K, Teiger E. Ann Cardiol Angeiol (Paris); 2007 Dec 01; 56(6):257-62. PubMed ID: 17988644 [Abstract] [Full Text] [Related]
13. [Experimental study in intraaortic balloon pumping and left ventricular assist device for left ventricular failure, individually and in combination; influence on coronary sinus flow and renal artery flow]. Orime Y. Nihon Kyobu Geka Gakkai Zasshi; 1986 Jun 01; 34(6):829-38. PubMed ID: 3760626 [No Abstract] [Full Text] [Related]
14. Right ventricular failure after repair of left ventricular aneurysm. Parr GV, Pierce WS, Rosenberg G, Waldhausen JA. J Thorac Cardiovasc Surg; 1980 Jul 01; 80(1):79-84. PubMed ID: 7382537 [No Abstract] [Full Text] [Related]
15. Phonocardiographic study of sounds produced by a circulatory assist device: report of a patient with a ruptured ventricular system. Clements SD, Whitaker A, Logue RB, Hurst JW. Arch Intern Med; 1977 Nov 01; 137(11):1619-20. PubMed ID: 921452 [Abstract] [Full Text] [Related]
16. [The use of an intra-aortic balloon in cardiac surgery: with reference to two cases (author's transl)]. Soyer R, Eisenmann B, de Riberolles C, Haas C, Diamant-Berger F, Letac B, Leroux G, Touchot B. Ann Chir Thorac Cardiovasc; 1975 Jan 01; 14(1):17-9. PubMed ID: 1122111 [No Abstract] [Full Text] [Related]
17. Pulmonary artery balloon counterpulsation for acute right ventricular failure. Miller DC, Moreno-Cabral RJ, Stinson EB, Shinn JA, Shumway NE. J Thorac Cardiovasc Surg; 1980 Nov 01; 80(5):760-3. PubMed ID: 7431972 [Abstract] [Full Text] [Related]
18. [Treatment of mechanical complications of recent myocardial infarction by intra-aortic counter-pressure and surgery (author's transl)]. Bourdarias JP, Bardet J, Kahn JC, Huret JF, Sanchez A, Benfarhat M. Ann Chir Thorac Cardiovasc; 1976 Oct 01; 30(9):245-51. PubMed ID: 999190 [No Abstract] [Full Text] [Related]
19. [An application of assisted circulation to extracorporeal circulation. Assisted circulation after the release of aortic cross clamping]. Yasuura K, Okamoto H, Yasuma F, Hirose S, Kondo T, Ogawa Y, Seki A. Kyobu Geka; 1984 Feb 01; 37(2):115-9. PubMed ID: 6716732 [No Abstract] [Full Text] [Related]
20. Eleven years' experience with the Pierce-Donachy ventricular assist device. Pennington DG, McBride LR, Miller LW, Swartz MT. J Heart Lung Transplant; 1994 Feb 01; 13(5):803-10. PubMed ID: 7803421 [Abstract] [Full Text] [Related] Page: [Next] [New Search]