These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
168 related items for PubMed ID: 37620182
1. Marginal fit and fracture resistance of polyetheretherketone, zirconia, and titanium implant-supported prosthesis frameworks for a partially edentulous arch after thermomechanical aging. Atsu S, Erol U. J Prosthet Dent; 2024 Feb; 131(2):273-280. PubMed ID: 37620182 [Abstract] [Full Text] [Related]
2. Effect of feldspathic porcelain layering on the marginal fit of zirconia and titanium complete-arch fixed implant-supported frameworks. Yilmaz B, Alshahrani FA, Kale E, Johnston WM. J Prosthet Dent; 2018 Jul; 120(1):71-78. PubMed ID: 29426786 [Abstract] [Full Text] [Related]
5. Effect of adhesive system, resin cement, heat-pressing technique, and thermomechanical aging on the adhesion between titanium base and a high-performance polymer. Yilmaz B, Gouveia D, Schimmel M, Lu WE, Özcan M, Abou-Ayash S. J Prosthet Dent; 2024 Mar; 131(3):468-474. PubMed ID: 35513915 [Abstract] [Full Text] [Related]
6. Fracture Resistance of Zirconia, Polyetheretherketone, and Polyetherketoneketone Implant Abutments After Aging. Türksayar AAD, Atsü SS. Int J Oral Maxillofac Implants; 2021 Mar; 36(2):332-340. PubMed ID: 33909724 [Abstract] [Full Text] [Related]
8. Randomized clinical trial of zirconia and polyetheretherketone implant abutments for single-tooth implant restorations: A 5-year evaluation. Ayyadanveettil P, Thavakkara V, Latha N, Pavanan M, Saraswathy A, Kuruniyan MS. J Prosthet Dent; 2022 Dec; 128(6):1275-1281. PubMed ID: 33933267 [Abstract] [Full Text] [Related]
9. Effect of framework material on the color of implant-supported complete-arch fixed dental prostheses. Yilmaz B, Alp G, Johnston WM. J Prosthet Dent; 2019 Jul; 122(1):69-75. PubMed ID: 30910280 [Abstract] [Full Text] [Related]
10. Failure analysis of high performance polymers and new generation cubic zirconia used for implant-supported fixed, cantilevered prostheses. Yilmaz B, Batak B, Seghi RR. Clin Implant Dent Relat Res; 2019 Dec; 21(6):1132-1139. PubMed ID: 31642185 [Abstract] [Full Text] [Related]
12. Effect of coping materials zirconia or polyetheretherketone with different techniques of fabrication on vertical marginal gap and fracture resistance of posterior crowns with composite veneering. Emam M, Metwally MF. BMC Oral Health; 2023 Aug 09; 23(1):546. PubMed ID: 37559037 [Abstract] [Full Text] [Related]
15. In vitro fit of CAD-CAM complete arch screw-retained titanium and zirconia implant prostheses fabricated on 4 implants. Al-Meraikhi H, Yilmaz B, McGlumphy E, Brantley W, Johnston WM. J Prosthet Dent; 2018 Mar 09; 119(3):409-416. PubMed ID: 28720339 [Abstract] [Full Text] [Related]
16. Fracture Resistance of Titanium, Zirconia, and Ceramic-Reinforced Polyetheretherketone Implant Abutments Supporting CAD/CAM Monolithic Lithium Disilicate Ceramic Crowns After Aging. Atsü SS, Aksan ME, Bulut AC. Int J Oral Maxillofac Implants; 2019 Mar 09; 34(3):622–630. PubMed ID: 30716141 [Abstract] [Full Text] [Related]
17. Fatigue and Stress Distribution Analyses of Ceramic-Reinforced PEEK Abutments Restored with Monolithic Zirconia Crowns as an Alternative to Conventional Esthetic Abutments. Akan E, Velioğlu E, Çömlekoğlu ME, Çömlekoğlu MD. Int J Oral Maxillofac Implants; 2022 Mar 09; 37(3):533-542. PubMed ID: 35727245 [Abstract] [Full Text] [Related]
18. Screw stability of CAD-CAM titanium and zirconia abutments on different implants: An in vitro study. Yilmaz B, Çakmak G, Batak B, Johnston WM. Clin Implant Dent Relat Res; 2021 Jun 09; 23(3):373-379. PubMed ID: 33938119 [Abstract] [Full Text] [Related]
19. Evaluation of the masking ability, marginal adaptation, and fracture resistance of screw-retained lithium disilicate implant-supported crowns cemented to titanium bases versus preparable abutments. Kordi AWM, Salman AI, Metwally NA, Khamis MM. BMC Oral Health; 2023 Aug 30; 23(1):613. PubMed ID: 37649061 [Abstract] [Full Text] [Related]
20. Fracture load of different veneered and implant-supported 4-UNIT cantilever PEEK fixed dental prostheses. Micovic Soldatovic D, Liebermann A, Huth KC, Stawarczyk B. J Mech Behav Biomed Mater; 2022 May 30; 129():105173. PubMed ID: 35286902 [Abstract] [Full Text] [Related] Page: [Next] [New Search]