These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
177 related items for PubMed ID: 37740783
1. Improved short-term outcomes for a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system compared to manual technique with fluoroscopic assistance. Buchan GBJ, Hecht CJ, Sculco PK, Chen JB, Kamath AF. Arch Orthop Trauma Surg; 2024 Jan; 144(1):501-508. PubMed ID: 37740783 [Abstract] [Full Text] [Related]
2. Use of a fluoroscopy-based robotic-assisted total hip arthroplasty system produced greater improvements in patient-reported outcomes at one year compared to manual, fluoroscopic-assisted technique. Buchan GBJ, Ong CB, Hecht Ii CJ, DeCook CA, Spencer-Gardner LS, Kamath AF. Arch Orthop Trauma Surg; 2024 Apr; 144(4):1843-1850. PubMed ID: 38400899 [Abstract] [Full Text] [Related]
3. Improved accuracy of a novel fluoroscopy-based robotically assisted THA system compared to manual THA. Buchan GBJ, Hecht CJ, Liu D, Mokete L, Kendoff D, Kamath AF. J Robot Surg; 2023 Oct; 17(5):2073-2079. PubMed ID: 37209355 [Abstract] [Full Text] [Related]
4. Fluoroscopy-based robotics in total hip arthroplasty mitigates laterality-based differences in acetabular cup placement when compared to the manual, fluoroscopic- assisted technique. Ong CB, Buchan GBJ, Hecht Ii CJ, Homma Y, Harmon DJ, Kendoff DO, Petterwood J, Kamath AF. Technol Health Care; 2024 Oct; 32(5):3693-3701. PubMed ID: 37980586 [Abstract] [Full Text] [Related]
5. Fluoroscopy-based robotic assistance for total hip arthroplasty improves acetabular cup placement accuracy for obese patients compared to the manual, fluoroscopic- assisted technique. Ong CB, Buchan GBJ, Hecht Ii CJ, Kendoff DO, Homma Y, Kamath AF. Technol Health Care; 2024 Oct; 32(5):3703-3712. PubMed ID: 37980587 [Abstract] [Full Text] [Related]
6. The Learning Curve From Converting From Fluoroscopic to Robotic-Assisted Direct Anterior Total Hip Arthroplasty. Masini MA, Sawaya KL, Harshberger A, Hameed D, Mont MA. Surg Technol Int; 2024 Jul 15; 44():311-319. PubMed ID: 38697134 [Abstract] [Full Text] [Related]
8. Improved perioperative narcotic usage patterns in patients undergoing robotic-assisted compared to manual total hip arthroplasty. Buchan GBJ, Bernhard Z, Hecht CJ, Davis GA, Pickering T, Kamath AF. Arthroplasty; 2023 Nov 04; 5(1):56. PubMed ID: 37924164 [Abstract] [Full Text] [Related]
9. Is there increased value in robotic arm-assisted total hip arthroplasty? : a nationwide outcomes, trends, and projections analysis of 4,699,894 cases. Emara AK, Zhou G, Klika AK, Koroukian SM, Schiltz NK, Higuera-Rueda CA, Molloy RM, Piuzzi NS. Bone Joint J; 2021 Sep 04; 103-B(9):1488-1496. PubMed ID: 34465149 [Abstract] [Full Text] [Related]
10. Improved accuracy and fewer outliers with a novel CT-free robotic THA system in matched-pair analysis with manual THA. Kamath AF, Durbhakula SM, Pickering T, Cafferky NL, Murray TG, Wind MA, Méthot S. J Robot Surg; 2022 Aug 04; 16(4):905-913. PubMed ID: 34709535 [Abstract] [Full Text] [Related]
12. The learning curve for a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system. Buchan GBJ, Hecht CJ, Lawrie CM, Sculco PK, Kamath AF. Int J Med Robot; 2023 Aug 04; 19(4):e2518. PubMed ID: 37058696 [Abstract] [Full Text] [Related]
13. Robotic-Assisted Total Hip Arthroplasty: Outcomes at Minimum Two-Year Follow-Up. Illgen RL, Bukowski BR, Abiola R, Anderson P, Chughtai M, Khlopas A, Mont MA. Surg Technol Int; 2017 Jul 25; 30():365-372. PubMed ID: 28537647 [Abstract] [Full Text] [Related]
15. Automated digital templating of component sizing is accurate in robotic total hip arthroplasty when compared to predicate software. Buchan GBJ, Hecht CJ, Rodriguez-Elizalde S, Kabata T, Kamath AF. Med Eng Phys; 2024 Feb 25; 124():104105. PubMed ID: 38418018 [Abstract] [Full Text] [Related]
16. Does acetabular robotic-assisted total hip arthroplasty with femoral navigation improve clinical outcomes at 1-year post-operative? A case-matched propensity score study comparing 98 robotic-assisted versus 98 manual implantation hip arthroplasties. Coulomb R, Cascales V, Haignere V, Bauzou F, Kouyoumdjian P. Orthop Traumatol Surg Res; 2023 Feb 25; 109(1):103477. PubMed ID: 36375721 [Abstract] [Full Text] [Related]
17. Length of Stay and Discharge Disposition After Total Hip Arthroplasty: A Large Multicenter Propensity Matched Comparison of Robotic-Assisted and Manual Techniques. Rajesh DA, Witvoet S, Coppolecchia A, Scholl L, Chen AF. J Arthroplasty; 2024 Sep 25; 39(9S1):S117-S123. PubMed ID: 38604284 [Abstract] [Full Text] [Related]
18. Short-term Clinical Outcomes of Robotic-Arm Assisted Total Hip Arthroplasty: A Pair-Matched Controlled Study. Perets I, Walsh JP, Mu BH, Mansor Y, Rosinsky PJ, Maldonado DR, Lall AC, Domb BG. Orthopedics; 2021 Sep 25; 44(2):e236-e242. PubMed ID: 33238012 [Abstract] [Full Text] [Related]
19. Robotic-assisted total hip arthroplasty utilizing a fluoroscopy-guided system resulted in improved intra-operative efficiency relative to a computerized tomography-based platform. Ong CB, Buchan GBJ, Hecht Ii CJ, Lawrie CM, DeCook CA, Sculco PK, Kamath AF. J Robot Surg; 2023 Dec 25; 17(6):2841-2847. PubMed ID: 37770721 [Abstract] [Full Text] [Related]
20. Cost-effectiveness of a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system: A Markov analysis. Ong CB, Buchan GBJ, Acuña AJ, Hecht CJ, Homma Y, Shah RP, Kamath AF. Int J Med Robot; 2023 Sep 30; ():e2582. PubMed ID: 37776329 [Abstract] [Full Text] [Related] Page: [Next] [New Search]