These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


301 related items for PubMed ID: 3782875

  • 1. [Continuous wave Doppler echocardiographic assessment of prosthetic aortic valves].
    Kisanuki A, Tei C, Arikawa K, Otsuji Y, Kawazoe Y, Natsugoe K, Tanaka H, Morishita Y, Taira A.
    J Cardiogr; 1986 Mar; 16(1):121-32. PubMed ID: 3782875
    [Abstract] [Full Text] [Related]

  • 2. [Continuous wave Doppler assessment of prosthetic valves in the mitral position: comparison of the St. Jude medical mechanical valve and the porcine xenograft valve].
    Kisanuki A, Tei C, Arikawa K, Natsugoe K, Otsuji Y, Kawazoe Y, Tanaka H, Morishita Y, Maruko M, Taira A.
    J Cardiogr; 1985 Dec; 15(4):1119-27. PubMed ID: 3841894
    [Abstract] [Full Text] [Related]

  • 3. [Doppler echocardiography in assessing mechanical and biological heart valve prostheses].
    Minardi G, Di Segni M, Boccardi L, Ferrari O, Giovannini E.
    G Ital Cardiol; 1988 Feb; 18(2):121-34. PubMed ID: 3410201
    [Abstract] [Full Text] [Related]

  • 4. [Doppler echocardiographic measurement of flow velocity in cases with a Björk-Shiley aortic prosthesis and diagnosis of prosthetic valve dysfunction].
    Miyazawa S, Matsui M, Sasaki T, Takakura H, Miyamoto N, Kuwata M, Arai T.
    Nihon Kyobu Geka Gakkai Zasshi; 1990 Jun; 38(6):953-9. PubMed ID: 2398291
    [Abstract] [Full Text] [Related]

  • 5. [Doppler evaluation of porcine mitral valve dysfunction].
    Nakamura K, Matsumura K, Satomi G, Sakai K, Ishizuka N, Mori K, Shiina T, Kikuchi N, Hirosawa K, Takao A.
    J Cardiogr; 1986 Dec; 16(4):929-39. PubMed ID: 3429909
    [Abstract] [Full Text] [Related]

  • 6. [Noninvasive determination of the orifice area of aortic valve prostheses using Doppler echocardiography].
    Dennig K, Rudolph W.
    Herz; 1986 Dec; 11(6):341-5. PubMed ID: 3817727
    [Abstract] [Full Text] [Related]

  • 7. Rest and exercise hemodynamics following aortic valve replacement. A comparison between 19 and 21 mm Ionescu-Shiley pericardial and Carpentier-Edwards porcine valves.
    Bove EL, Marvasti MA, Potts JL, Reger MJ, Zamora JL, Eich RH, Parker FB.
    J Thorac Cardiovasc Surg; 1985 Nov; 90(5):750-5. PubMed ID: 4058047
    [Abstract] [Full Text] [Related]

  • 8. Normal and abnormal prosthetic valve function as assessed by Doppler echocardiography.
    Panidis IP, Ross J, Mintz GS.
    J Am Coll Cardiol; 1986 Aug; 8(2):317-26. PubMed ID: 2942593
    [Abstract] [Full Text] [Related]

  • 9. [Non-invasive determination of pressure gradients of heart valve prostheses using Doppler ultrasound].
    Hoffmann A, Amann FW, Grädel E, Burckhardt D.
    Schweiz Med Wochenschr; 1982 Nov 06; 112(45):1600-3. PubMed ID: 7156956
    [Abstract] [Full Text] [Related]

  • 10. Early Doppler-echocardiography evaluation of 597 prosthetic aortic valves.
    Minardi G, Pino PG, Manzara CC, Pulignano G, Viceconte GN, Stefanini GG, Gaudio C, Musumeci F.
    J Cardiovasc Med (Hagerstown); 2010 Apr 06; 11(4):229-33. PubMed ID: 20090552
    [Abstract] [Full Text] [Related]

  • 11. Doppler ultrasound examination of prosthetic function and ventricular blood flow after mitral valve replacement.
    Omoto R, Matsumura M, Asano H, Kyo S, Takamoto S, Yokote Y, Wong M.
    Herz; 1986 Dec 06; 11(6):346-50. PubMed ID: 2950039
    [Abstract] [Full Text] [Related]

  • 12. Comparison of magnetic resonance imaging and Laser Doppler Anemometry velocity measurements downstream of replacement heart valves: implications for in vivo assessment of prosthetic valve function.
    Fontaine AA, Heinrich RS, Walker PG, Pedersen EM, Scheidegger MB, Boesiger P, Walton SP, Yoganathan AP.
    J Heart Valve Dis; 1996 Jan 06; 5(1):66-73. PubMed ID: 8834728
    [Abstract] [Full Text] [Related]

  • 13. [Intracardiac flow dynamic alterations with a prosthetic mitral valve studied by pulsed Doppler technique].
    Kitabatake A, Tanouchi J, Asao M, Mishima M, Ishihara K, Masuyama T, Inoue M, Abe H, Matsuo H, Morita H.
    J Cardiogr; 1985 Jun 06; 15(2):469-82. PubMed ID: 4093627
    [Abstract] [Full Text] [Related]

  • 14. [Flow patterns of a normally functioning monocuspid aortic prosthesis evaluated using Doppler echocardiography].
    Bernardes L, Abreu J, Matos P, Ramos JM, Quininha J, Salomão S.
    Rev Port Cardiol; 1989 Mar 06; 8(3):191-5. PubMed ID: 2631841
    [Abstract] [Full Text] [Related]

  • 15. [Continuous wave Doppler echocardiographic assessment of aortic stenosis and aortic regurgitation].
    Tei C, Kisanuki A, Arikawa K, Otsuji Y, Arima S, Kashima T, Tanaka H, Kushitani M, Shah PM.
    J Cardiogr; 1985 Mar 06; 15(1):111-21. PubMed ID: 4067338
    [Abstract] [Full Text] [Related]

  • 16. Aortic prosthetic valve design and size: relation to Doppler echocardiographic findings and pressure recovery- an in vitro study.
    Bech-Hanssen O, Caidahl K, Wallentin I, Brandberg J, Wranne B, Ask P.
    J Am Soc Echocardiogr; 2000 Jan 06; 13(1):39-50. PubMed ID: 10625830
    [Abstract] [Full Text] [Related]

  • 17. [Doppler echocardiographic assessment of prosthetic heart valve function].
    Fan CM.
    Zhonghua Wai Ke Za Zhi; 1993 Oct 06; 31(10):630-2. PubMed ID: 8033679
    [Abstract] [Full Text] [Related]

  • 18. Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus.
    Wagner IM, Eichinger WB, Bleiziffer S, Botzenhardt F, Gebauer I, Guenzinger R, Bauernschmitt R, Lange R.
    J Thorac Cardiovasc Surg; 2007 May 06; 133(5):1234-41. PubMed ID: 17467435
    [Abstract] [Full Text] [Related]

  • 19. [Usefulness of magnetic resonance imaging for managing patients with prosthetic carbon valve in the mitral position].
    Koito H, Imai Y, Suzuki J, Ohkubo N, Nakamura C, Takahashi H, Iwasaka T, Inada M.
    J Cardiol; 1997 Nov 06; 30(5):251-63. PubMed ID: 9395956
    [Abstract] [Full Text] [Related]

  • 20. [Rest and exercise performance of allografts, Bicer valves and St. Jude Medical valves in the aortic position].
    Hasegawa J, Kitamura S, Kawachi K, Kawata T, Niwaya K, Kameda Y, Mizuguchi K, Kobayashi S, Yoshida Y.
    Nihon Kyobu Geka Gakkai Zasshi; 1995 Aug 06; 43(8):1132-7. PubMed ID: 7594847
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 16.