These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
120 related items for PubMed ID: 37831823
1. Precision Doppler shift measurements with a frequency comb calibrated laser heterodyne radiometer. Cole RK, Fredrick C, Nguyen NH, Diddams SA. Opt Lett; 2023 Oct 15; 48(20):5185-5188. PubMed ID: 37831823 [Abstract] [Full Text] [Related]
3. Simultaneous detection of multi-component greenhouse gases based on an all-fibered near-infrared single-channel frequency-division multiplexing wavelength-modulated laser heterodyne radiometer. Sun C, He X, Zhang K, Bai J, Liu X. Spectrochim Acta A Mol Biomol Spectrosc; 2023 May 15; 293():122434. PubMed ID: 36773419 [Abstract] [Full Text] [Related]
4. High-resolution oxygen-corrected laser heterodyne radiometer (LHR) for stratospheric and tropospheric wind field detection. Li J, Xue Z, Shen F, Wang G, Liu K, Chen W, Gao X, Tan T. Opt Express; 2023 Feb 27; 31(5):7850-7862. PubMed ID: 36859908 [Abstract] [Full Text] [Related]
6. [Study on the Technology of the 4.4 μm Mid-Infrared Laser Heterodyne Spectrum]. Tan T, Cao ZS, Wang GS, Wang L, Liu K, Huang YB, Chen Wei-dong, Gao WM. Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Jun 27; 35(6):1516-9. PubMed ID: 26601358 [Abstract] [Full Text] [Related]
7. Laser heterodyne spectroradiometer assisted by self-calibrated wavelength modulation spectroscopy for atmospheric CO2 column absorption measurements. Deng H, Li M, He Y, Xu Z, Yao L, Chen B, Yang C, Kan R. Spectrochim Acta A Mol Biomol Spectrosc; 2020 Apr 05; 230():118071. PubMed ID: 31958604 [Abstract] [Full Text] [Related]
8. Performance Characterization of a Fully Transportable Mid-Infrared Laser Heterodyne Radiometer (LHR). Shen F, Hu X, Lu J, Xue Z, Li J, Tan T, Cao Z, Gao X, Chen W. Sensors (Basel); 2023 Jan 14; 23(2):. PubMed ID: 36679777 [Abstract] [Full Text] [Related]
10. Coherent multi-heterodyne spectroscopy using acousto-optic frequency combs. Durán V, Schnébelin C, Guillet de Chatellus H. Opt Express; 2018 May 28; 26(11):13800-13809. PubMed ID: 29877427 [Abstract] [Full Text] [Related]
11. Development of a laser heterodyne spectroradiometer for high-resolution measurements of CO2, CH4, H2O and O2 in the atmospheric column. Deng H, Yang C, Xu Z, Li M, Huang A, Yao L, Hu M, Chen B, He Y, Kan R, Liu J. Opt Express; 2021 Jan 18; 29(2):2003-2013. PubMed ID: 33726402 [Abstract] [Full Text] [Related]
12. Comb-calibrated frequency-modulated continuous-wave ladar for absolute distance measurements. Baumann E, Giorgetta FR, Coddington I, Sinclair LC, Knabe K, Swann WC, Newbury NR. Opt Lett; 2013 Jun 15; 38(12):2026-8. PubMed ID: 23938965 [Abstract] [Full Text] [Related]
19. A portable miniaturized laser heterodyne radiometer (mini‑LHR) for remote measurements of column CH4 and CO2. Wilson EL, DiGregorio AJ, Villanueva G, Grunberg CE, Souders Z, Miletti KM, Menendez A, Grunberg MH, Floyd MAM, Bleacher JE, Euskirchen ES, Edgar C, Caldwell BJ, Shiro B, Binsted K. Appl Phys B; 2019 Oct 21; 125(211):. PubMed ID: 31920221 [Abstract] [Full Text] [Related]
20. Mid-infrared laser heterodyne radiometer (LHR) based on a 3.53 μm room-temperature interband cascade laser. Wang J, Wang G, Tan T, Zhu G, Sun C, Cao Z, Chen W, Gao X. Opt Express; 2019 Apr 01; 27(7):9610-9619. PubMed ID: 31045110 [Abstract] [Full Text] [Related] Page: [Next] [New Search]