These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
46. Changes in blood gas samples produced by a pneumatic tube system. Collinson PO, John CM, Gaze DC, Ferrigan LF, Cramp DG. J Clin Pathol; 2002 Feb; 55(2):105-7. PubMed ID: 11865003 [Abstract] [Full Text] [Related]
47. [Transport of blood gas samples: is the pneumatic tube system safe?]. Zanner R, Moser N, Blobner M, Luppa PB. Anaesthesist; 2006 Oct; 55(10):1099-104. PubMed ID: 16850326 [Abstract] [Full Text] [Related]
48. An episode of increased hemolysis due to a defective pneumatic air tube delivery system. Ellis G. Clin Biochem; 2009 Aug; 42(12):1265-9. PubMed ID: 19445913 [Abstract] [Full Text] [Related]
49. Pneumatic tube system transport and false hyperkalemia related to leukocytosis: a retrospective analysis. Grzych G, Roland E, Lezier D, Beauvais D, Maboudou P, Lippi G. Ann Biol Clin (Paris); 2019 Jun 01; 77(3):281-286. PubMed ID: 31115339 [Abstract] [Full Text] [Related]
51. Sample transport by pneumatic tube system alters results of multiple electrode aggregometry but not rotational thromboelastometry. Glas M, Mauer D, Kassas H, Volk T, Kreuer S. Platelets; 2013 Jun 01; 24(6):454-61. PubMed ID: 22931353 [Abstract] [Full Text] [Related]
52. Blood gas analysis: POCT versus central laboratory on samples sent by a pneumatic tube system. Zaman Z, Demedts M. Clin Chim Acta; 2001 May 01; 307(1-2):101-6. PubMed ID: 11369343 [Abstract] [Full Text] [Related]
53. The effects of transport by pneumatic tube system on urine analysis. Kosem A, Topcuoglu C, Sezer S, Demir E, Turhan T. Scand J Clin Lab Invest; 2021 Sep 01; 81(5):361-364. PubMed ID: 34346281 [Abstract] [Full Text] [Related]
54. Evaluation of a soft-handling computerized pneumatic tube specimen delivery system. Effects on analytical results and turnaround time. Keshgegian AA, Bull GE. Am J Clin Pathol; 1992 Apr 01; 97(4):535-40. PubMed ID: 1553919 [Abstract] [Full Text] [Related]
55. A paradigmatic case of haemolysis and pseudohyperkalemia in blood gas analysis. Salvagno GL, Demonte D, Lippi G. Biochem Med (Zagreb); 2019 Feb 15; 29(1):011003. PubMed ID: 30799980 [Abstract] [Full Text] [Related]
56. Pre-analytical effects of pneumatic tube system transport on routine haematology and coagulation tests, global coagulation assays and platelet function assays. Le Quellec S, Paris M, Nougier C, Sobas F, Rugeri L, Girard S, Bordet JC, Négrier C, Dargaud Y. Thromb Res; 2017 May 15; 153():7-13. PubMed ID: 28292729 [Abstract] [Full Text] [Related]
57. Hemolysis of blood specimens transported from ED to laboratory by pneumatic tube. Stair TO, Howell JM, Fitzgerald DJ, Bailey SC, Bastasch MD. Am J Emerg Med; 1995 Jul 15; 13(4):484. PubMed ID: 7605542 [No Abstract] [Full Text] [Related]
58. Pre-analytical effects of pneumatic tube transport on impedance platelet aggregometry. Bolliger D, Seeberger MD, Tanaka KA, Dell-Kuster S, Gregor M, Zenklusen U, Grapow M, Tsakiris DA, Filipovic M. Platelets; 2009 Nov 15; 20(7):458-65. PubMed ID: 19852683 [Abstract] [Full Text] [Related]
59. Evaluation of the BD Vacutainer(®) RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study. Kocijancic M, Cargonja J, Delic-Knezevic A. Biochem Med (Zagreb); 2014 Nov 15; 24(3):368-75. PubMed ID: 25351355 [Abstract] [Full Text] [Related]
60. Blood Sample Transportation by Pneumatic Transportation Systems: A Systematic Literature Review. Nybo M, Lund ME, Titlestad K, Maegaard CU. Clin Chem; 2018 May 15; 64(5):782-790. PubMed ID: 29222338 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]