These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Commissioning and quality assurance for VMAT delivery systems: An efficient time-resolved system using real-time EPID imaging. Zwan BJ, Barnes MP, Hindmarsh J, Lim SB, Lovelock DM, Fuangrod T, O'Connor DJ, Keall PJ, Greer PB. Med Phys; 2017 Aug; 44(8):3909-3922. PubMed ID: 28564208 [Abstract] [Full Text] [Related]
4. Monitoring daily MLC positional errors using trajectory log files and EPID measurements for IMRT and VMAT deliveries. Agnew A, Agnew CE, Grattan MW, Hounsell AR, McGarry CK. Phys Med Biol; 2014 May 07; 59(9):N49-63. PubMed ID: 24732210 [Abstract] [Full Text] [Related]
5. Daily QA of linear accelerators using only EPID and OBI. Sun B, Goddu SM, Yaddanapudi S, Noel C, Li H, Cai B, Kavanaugh J, Mutic S. Med Phys; 2015 Oct 07; 42(10):5584-94. PubMed ID: 26429233 [Abstract] [Full Text] [Related]
6. Is a weekly qualitative picket fence test sufficient? A proposed alternate EPID-based weekly MLC QA program. Kalavagunta C, Xu H, Zhang B, Mossahebi S, MacFarlane M, Jiang K, Lee SW, Chen S, Sawant A, Gopal A, Yi B. J Appl Clin Med Phys; 2022 Aug 07; 23(8):e13699. PubMed ID: 35856943 [Abstract] [Full Text] [Related]
10. Evaluation of QA software system analysis for the static picket fence test. Boudet J, Aubignac L, Beneux A, Mazoyer F, Bessieres I. J Appl Clin Med Phys; 2022 Jul 07; 23(7):e13618. PubMed ID: 35570379 [Abstract] [Full Text] [Related]
11. Automating linear accelerator quality assurance. Eckhause T, Al-Hallaq H, Ritter T, DeMarco J, Farrey K, Pawlicki T, Kim GY, Popple R, Sharma V, Perez M, Park S, Booth JT, Thorwarth R, Moran JM. Med Phys; 2015 Oct 07; 42(10):6074-83. PubMed ID: 26429282 [Abstract] [Full Text] [Related]
12. Sensitivity study of an automated system for daily patient QA using EPID exit dose images. Zhuang AH, Olch AJ. J Appl Clin Med Phys; 2018 May 07; 19(3):114-124. PubMed ID: 29508529 [Abstract] [Full Text] [Related]
13. A novel technique for VMAT QA with EPID in cine mode on a Varian TrueBeam linac. Liu B, Adamson J, Rodrigues A, Zhou F, Yin FF, Wu Q. Phys Med Biol; 2013 Oct 07; 58(19):6683-700. PubMed ID: 24018655 [Abstract] [Full Text] [Related]
14. A tool for patient-specific prediction of delivery discrepancies in machine parameters using trajectory log files. Chuang KC, Giles W, Adamson J. Med Phys; 2021 Mar 07; 48(3):978-990. PubMed ID: 33332618 [Abstract] [Full Text] [Related]
15. Automatic detection of MLC relative position errors for VMAT using the EPID-based picket fence test. Christophides D, Davies A, Fleckney M. Phys Med Biol; 2016 Dec 07; 61(23):8340-8359. PubMed ID: 27811392 [Abstract] [Full Text] [Related]
16. EPID sensitivity to delivery errors for pre-treatment verification of lung SBRT VMAT plans. Alharthi T, Arumugam S, Vial P, Holloway L, Thwaites D. Phys Med; 2019 Mar 07; 59():37-46. PubMed ID: 30928064 [Abstract] [Full Text] [Related]
17. An error detection method for real-time EPID-based treatment delivery quality assurance. Alves VGL, Ahmed M, Aliotta E, Choi W, Siebers JV. Med Phys; 2021 Feb 07; 48(2):569-578. PubMed ID: 33314247 [Abstract] [Full Text] [Related]
19. Evaluation of the Impact of the Linac MLC and Gantry Sag in volumetric modulated arc therapy. Milan T, Grogan G, Ebert MA, Rowshanfarzad P. Med Phys; 2019 May 07; 46(5):1984-1994. PubMed ID: 30870581 [Abstract] [Full Text] [Related]