These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
115 related items for PubMed ID: 38380700
1. Improvements in Between-Vendor MRI Harmonization of Renal T2 Mapping using Stimulated Echo Compensation. Li H, Daniel AJ, Buchanan CE, Nery F, Morris DM, Li S, Huang Y, Sousa JA, Sourbron S, Mendichovszky IA, Thomas DL, Priest AN, Francis ST. J Magn Reson Imaging; 2024 Nov; 60(5):2144-2155. PubMed ID: 38380700 [Abstract] [Full Text] [Related]
7. Repeatability of magnetic resonance fingerprinting T1 and T2 estimates assessed using the ISMRM/NIST MRI system phantom. Jiang Y, Ma D, Keenan KE, Stupic KF, Gulani V, Griswold MA. Magn Reson Med; 2017 Oct; 78(4):1452-1457. PubMed ID: 27790751 [Abstract] [Full Text] [Related]
8. T2 mapping of the heart with a double-inversion radial fast spin-echo method with indirect echo compensation. Hagio T, Huang C, Abidov A, Singh J, Ainapurapu B, Squire S, Bruck D, Altbach MI. J Cardiovasc Magn Reson; 2015 Feb 25; 17(1):24. PubMed ID: 25889928 [Abstract] [Full Text] [Related]
9. Comprehensive Evaluation of B1+-corrected FISP-based Magnetic Resonance Fingerprinting: Accuracy, Repeatability and Reproducibility of T1 and T2 Relaxation Times for ISMRM/NIST System Phantom and Volunteers. Kato Y, Ichikawa K, Okudaira K, Taoka T, Kawaguchi H, Murata K, Maruyama K, Koerzdoerfer G, Pfeuffer J, Nittka M, Naganawa S. Magn Reson Med Sci; 2020 Aug 03; 19(3):168-175. PubMed ID: 31217366 [Abstract] [Full Text] [Related]
10. Whole brain quantitative T2 MRI across multiple scanners with dual echo FSE: applications to AD, MCI, and normal aging. Bauer CM, Jara H, Killiany R, Alzheimer's Disease Neuroimaging Initiative. Neuroimage; 2010 Aug 15; 52(2):508-14. PubMed ID: 20441797 [Abstract] [Full Text] [Related]
11. Temperature dependence, accuracy, and repeatability of T1 and T2 relaxation times for the ISMRM/NIST system phantom measured using MR fingerprinting. Statton BK, Smith J, Finnegan ME, Koerzdoerfer G, Quest RA, Grech-Sollars M. Magn Reson Med; 2022 Mar 15; 87(3):1446-1460. PubMed ID: 34752644 [Abstract] [Full Text] [Related]
12. T1, T2, and Fat Fraction Cardiac MR Fingerprinting: Preliminary Clinical Evaluation. Jaubert O, Cruz G, Bustin A, Hajhosseiny R, Nazir S, Schneider T, Koken P, Doneva M, Rueckert D, Masci PG, Botnar RM, Prieto C. J Magn Reson Imaging; 2021 Apr 15; 53(4):1253-1265. PubMed ID: 33124081 [Abstract] [Full Text] [Related]