These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
145 related items for PubMed ID: 38621698
1. On-X aortic valve replacement patients treated with low-dose warfarin and low-dose aspirin. Oo AY, Loubani M, Gerdisch MW, Zacharias J, Tsang GM, Perchinsky MJ, Hagberg RC, Joseph M, Sathyamoorthy M. Eur J Cardiothorac Surg; 2024 May 03; 65(5):. PubMed ID: 38621698 [Abstract] [Full Text] [Related]
2. Reduced anticoagulation after mechanical aortic valve replacement: interim results from the prospective randomized on-X valve anticoagulation clinical trial randomized Food and Drug Administration investigational device exemption trial. Puskas J, Gerdisch M, Nichols D, Quinn R, Anderson C, Rhenman B, Fermin L, McGrath M, Kong B, Hughes C, Sethi G, Wait M, Martin T, Graeve A, PROACT Investigators. J Thorac Cardiovasc Surg; 2014 Apr 03; 147(4):1202-1210; discussion 1210-1. PubMed ID: 24512654 [Abstract] [Full Text] [Related]
3. Low-Dose vs Standard Warfarin After Mechanical Mitral Valve Replacement: A Randomized Trial. Chu MWA, Ruel M, Graeve A, Gerdisch MW, Damiano RJ, Smith RL, Keeling WB, Wait MA, Hagberg RC, Quinn RD, Sethi GK, Floridia R, Barreiro CJ, Pruitt AL, Accola KD, Dagenais F, Markowitz AH, Ye J, Sekela ME, Tsuda RY, Duncan DA, Swistel DG, Harville LE, DeRose JJ, Lehr EJ, Alexander JH, Puskas JD, PROACT Mitral Investigators. Ann Thorac Surg; 2023 Apr 03; 115(4):929-938. PubMed ID: 36610532 [Abstract] [Full Text] [Related]
4. D-dimer to guide the intensity of anticoagulation in Chinese patients after mechanical heart valve replacement: a randomized controlled trial. Zhang L, Zheng X, Long Y, Wu M, Chen Y, Yang J, Liu Z, Zhang Z. J Thromb Haemost; 2017 Oct 03; 15(10):1934-1941. PubMed ID: 28762606 [Abstract] [Full Text] [Related]
5. Anticoagulation and Antiplatelet Strategies After On-X Mechanical Aortic Valve Replacement. Puskas JD, Gerdisch M, Nichols D, Fermin L, Rhenman B, Kapoor D, Copeland J, Quinn R, Hughes GC, Azar H, McGrath M, Wait M, Kong B, Martin T, Douville EC, Meyer S, Ye J, Jamieson WRE, Landvater L, Hagberg R, Trotter T, Armitage J, Askew J, Accola K, Levy P, Duncan D, Yanagawa B, Ely J, Graeve A, PROACT Investigators. J Am Coll Cardiol; 2018 Jun 19; 71(24):2717-2726. PubMed ID: 29903344 [Abstract] [Full Text] [Related]
6. Antithrombotic therapy after bioprosthetic aortic valve implantation: Warfarin versus aspirin, a randomized controlled trial. Rafiq S, Steinbrüchel DA, Lilleør NB, Møller CH, Lund JT, Thiis JJ, Køber L, Olsen PS. Thromb Res; 2017 Feb 19; 150():104-110. PubMed ID: 27914653 [Abstract] [Full Text] [Related]
7. Aniticoagulation in patients following prosthetic heart valve replacement. Akhtar RP, Abid AR, Zafar H, Khan JS. Ann Thorac Cardiovasc Surg; 2009 Feb 19; 15(1):10-7. PubMed ID: 19262444 [Abstract] [Full Text] [Related]
8. Anticoagulation After Biological Aortic Valve Replacement: Is There An Optimal Regimen? Owais T, Rouman M, Breuer M, Hüter L, Fuchs J, Lauer B, Kuntze T. J Heart Valve Dis; 2016 Mar 19; 25(2):139-144. PubMed ID: 27989055 [Abstract] [Full Text] [Related]
9. Optimal INR level for warfarin therapy after mechanical mitral valve replacement. Kamthornthanakarn I, Krittayaphong R. BMC Cardiovasc Disord; 2019 Apr 25; 19(1):97. PubMed ID: 31023235 [Abstract] [Full Text] [Related]
10. Low-dose warfarin with a novel mechanical aortic valve: Interim registry results at 5-year follow-up. Gerdisch MW, Hagberg RC, Perchinsky MJ, Joseph M, Oo AY, Loubani M, Tsang GM, Zacharias J, Sathyamoorthy M. J Thorac Cardiovasc Surg; 2024 Apr 28. PubMed ID: 38688451 [Abstract] [Full Text] [Related]
11. Rationale and design of PROACT Xa: A randomized, multicenter, open-label, clinical trial to evaluate the efficacy and safety of apixaban versus warfarin in patients with a mechanical On-X Aortic Heart Valve. Jawitz OK, Wang TY, Lopes RD, Chavez A, Boyer B, Kim H, Anstrom KJ, Becker RC, Blackstone E, Ruel M, Thourani VH, Puskas JD, Gerdisch MW, Johnston D, Capps S, Alexander JH, Svensson LG. Am Heart J; 2020 Sep 28; 227():91-99. PubMed ID: 32693197 [Abstract] [Full Text] [Related]
12. Optimal Intensity of Warfarin Therapy in Patients With Mechanical Aortic Valves. Kido K, Ball J. J Pharm Pract; 2019 Feb 28; 32(1):93-98. PubMed ID: 28982306 [Abstract] [Full Text] [Related]
13. Safety and Use of Anticoagulation After Aortic Valve Replacement With Bioprostheses: A Meta-Analysis. Riaz H, Alansari SA, Khan MS, Riaz T, Raza S, Luni FK, Khan AR, Riaz IB, Krasuski RA. Circ Cardiovasc Qual Outcomes; 2016 May 28; 9(3):294-302. PubMed ID: 27166205 [Abstract] [Full Text] [Related]
14. Relationship of international normalized ratio to bleeding and thromboembolism rates in Taiwanese patients receiving vitamin K antagonist after mechanical valve replacement. Yu HY, Liu CH, Chen YS, Wang SS, Chu SH, Lin FY. J Formos Med Assoc; 2005 Apr 28; 104(4):236-43. PubMed ID: 15909060 [Abstract] [Full Text] [Related]
15. Early anticoagulation of bioprosthetic aortic valves in older patients: results from the Society of Thoracic Surgeons Adult Cardiac Surgery National Database. Brennan JM, Edwards FH, Zhao Y, O'Brien S, Booth ME, Dokholyan RS, Douglas PS, Peterson ED, DEcIDE AVR Research Team. J Am Coll Cardiol; 2012 Sep 11; 60(11):971-7. PubMed ID: 22921973 [Abstract] [Full Text] [Related]
16. Low-intensity oral anticoagulant plus low-dose aspirin during the first six months versus standard-intensity oral anticoagulant therapy after mechanical heart valve replacement: a pilot study of low-intensity warfarin and aspirin in cardiac prostheses (LIWACAP). Pengo V, Palareti G, Cucchini U, Molinatti M, Del Bono R, Baudo F, Ghirarduzzi A, Pegoraro C, Iliceto S, participating centers of Italian Federation of Anticoagulation Clinics (FCSA). Clin Appl Thromb Hemost; 2007 Jul 11; 13(3):241-8. PubMed ID: 17636186 [Abstract] [Full Text] [Related]
17. Patterns of anticoagulation following bioprosthetic valve implantation: observations from ANSWER. Brennan JM, Alexander KP, Wallace A, Hodges AB, Laschinger JC, Jones KW, O'Brien S, Webb LE, Dokholyan RS, Peterson ED. J Heart Valve Dis; 2012 Jan 11; 21(1):78-87. PubMed ID: 22474747 [Abstract] [Full Text] [Related]