These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
253 related items for PubMed ID: 3898973
1. A comparison of the measurement of sodium and potassium by flame photometry and ion-selective electrode. Worth HG. Ann Clin Biochem; 1985 Jul; 22 ( Pt 4)():343-50. PubMed ID: 3898973 [Abstract] [Full Text] [Related]
2. Measurements of sodium and potassium in newborns and prematures by ion-selective electrodes and flame photometry: influence of lipid and protein content of blood. Kau N, Günther M, Fahnenstich H, Kowalewski S, Bartmann P. Acta Anaesthesiol Scand Suppl; 1995 Jul; 107():107-11. PubMed ID: 8599260 [Abstract] [Full Text] [Related]
3. [Comparison of ion-selective electrodes and flame photometry for the determination of serum Na+ and K+ for clinical purposes (author's transl)]. Preusse CJ, Fuchs C. J Clin Chem Clin Biochem; 1979 Oct; 17(10):639-45. PubMed ID: 501292 [Abstract] [Full Text] [Related]
4. [Evaluation of enzymatic methods for the determination of plasma sodium and potassium using the Hitachi 747 analytic system]. Pei P, Cigler C, Vonderschmitt DJ. Schweiz Med Wochenschr; 1991 Dec 14; 121(50):1883-6. PubMed ID: 1759149 [Abstract] [Full Text] [Related]
5. Interference from heparin in commercial heparinised tubes in the measurement of plasma sodium by ion selective electrode: a note of caution. Mann SW, Green A. Ann Clin Biochem; 1986 May 14; 23 ( Pt 3)():355-6. PubMed ID: 3789645 [No Abstract] [Full Text] [Related]
6. A comparison of reference method values for sodium, potassium and chloride with method-dependent assigned values. Külpmann WR, Lagemann J, Sander R, Maibaum P. J Clin Chem Clin Biochem; 1985 Dec 14; 23(12):865-74. PubMed ID: 3831226 [Abstract] [Full Text] [Related]
10. Effect of moderate hypercholesterolemia on recognition of hypernatremia using indirect measurements of serum sodium and potassium concentrations. Naskalski JW, Solnica B, Gernand W. Clin Lab; 2007 Dec 14; 53(7-8):441-7. PubMed ID: 17821948 [Abstract] [Full Text] [Related]
12. Errors due to heparin in the estimation of plasma sodium and potassium concentrations. Shek CC, Swaminathan R. Intensive Care Med; 1985 Dec 14; 11(6):309-11. PubMed ID: 4086706 [Abstract] [Full Text] [Related]
13. Recommendation for measuring and reporting chloride by ISEs in undiluted serum, plasma or blood. Rayana MC, Burnett RW, Covington AK, D'Orazio P, Fogh-Andersen N, Jacobs E, Kataky R, Külpmann WR, Kuwa K, Larsson L, Lewenstam A, Maas AH, Mager G, Naskalski JW, Okorodudu AO, Ritter C, St John A, International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). Clin Chem Lab Med; 2006 Dec 14; 44(3):346-52. PubMed ID: 16519610 [Abstract] [Full Text] [Related]
16. Sodium and potassium measurements: direct potentiometry and flame photometry. MacDonald NF, Williams PZ, Burton JI, Batsakis JG. Am J Clin Pathol; 1981 Oct 14; 76(4 Suppl):575-7. PubMed ID: 7282643 [Abstract] [Full Text] [Related]
17. Clinical evaluation of sodium ion selective field effect transistors for whole blood assay. Thompson JM, Smith SC, Cramb R, Hutton P. Ann Clin Biochem; 1994 Jan 14; 31 ( Pt 1)():12-7. PubMed ID: 8154847 [Abstract] [Full Text] [Related]