These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
114 related items for PubMed ID: 39244478
1. Correlation, agreement and concordance of cardiac output estimated by transthoracic ultrasound and transesophageal Doppler with pulmonary artery thermodilution in anesthetized cats. Pypendop BH, Rivas VN, Bueno MC, Chohan AS, Barter LS, Stern JA. Vet Anaesth Analg; 2024; 51(6):641-649. PubMed ID: 39244478 [Abstract] [Full Text] [Related]
2. Comparison of pulmonary artery and transpulmonary thermodilution cardiac output measurements in unsedated newborn calves. Kutter AP, Jud Schefer RS, Bircher B, Bleul U, Bettschart-Wolfensberger R. Vet Anaesth Analg; 2015 Nov; 42(6):614-22. PubMed ID: 25689575 [Abstract] [Full Text] [Related]
3. Evaluation of agreement and trending ability between transpulmonary thermodilution and calibrated pulse contour and pulse power cardiac output monitoring methods against pulmonary artery thermodilution in anesthetized dogs. Kutter AP, Bettschart-Wolfensberger R, Romagnoli N, Bektas RN. J Vet Emerg Crit Care (San Antonio); 2016 Jul; 26(4):531-40. PubMed ID: 26754858 [Abstract] [Full Text] [Related]
7. Agreement of cardiac output measurements by esophageal Doppler and transesophageal echocardiography with intermittent pulmonary artery thermodilution during pharmacologic manipulation of hemodynamics in anesthetized dogs. Paranjape VV, Pereira FLG, Menciotti G, Saksena S, Guerrero NH, Pereira CHR. Am J Vet Res; 2023 Aug 01; 84(8):. PubMed ID: 37385599 [Abstract] [Full Text] [Related]
8. Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting. Missant C, Rex S, Wouters PF. Eur J Anaesthesiol; 2008 Mar 01; 25(3):243-8. PubMed ID: 17996125 [Abstract] [Full Text] [Related]
10. Cardiac output estimation using multi-beat analysis of the radial arterial blood pressure waveform: a method comparison study in patients having off-pump coronary artery bypass surgery using intermittent pulmonary artery thermodilution as the reference method. Saugel B, Heeschen J, Hapfelmeier A, Romagnoli S, Greiwe G. J Clin Monit Comput; 2020 Aug 01; 34(4):649-654. PubMed ID: 31456072 [Abstract] [Full Text] [Related]
12. Cardiac output estimation by multi-beat analysis of the radial arterial blood pressure waveform versus intermittent pulmonary artery thermodilution: a method comparison study in patients treated in the intensive care unit after off-pump coronary artery bypass surgery. Greiwe G, Peters V, Hapfelmeier A, Romagnoli S, Kubik M, Saugel B. J Clin Monit Comput; 2020 Aug 01; 34(4):643-648. PubMed ID: 31456071 [Abstract] [Full Text] [Related]
13. Evaluation of an oesophageal Doppler device for monitoring cardiac output in anaesthetised healthy normotensive dogs. Canfrán S, Cediel R, Sández I, Caro-Vadillo A, Gómez de Segura IA. J Small Anim Pract; 2015 Jul 01; 56(7):450-5. PubMed ID: 25913545 [Abstract] [Full Text] [Related]
15. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution. Graeser K, Zemtsovski M, Kofoed KF, Winther-Jensen M, Nilsson JC, Kjaergaard J, Møller-Sørensen H. Anesth Analg; 2018 Aug 01; 127(2):399-407. PubMed ID: 29324489 [Abstract] [Full Text] [Related]
16. Measurements of cardiac output obtained with transesophageal echocardiography and pulmonary artery thermodilution are not interchangeable. Møller-Sørensen H, Graeser K, Hansen KL, Zemtsovski M, Sander EM, Nilsson JC. Acta Anaesthesiol Scand; 2014 Jan 01; 58(1):80-8. PubMed ID: 24192143 [Abstract] [Full Text] [Related]
17. [Comparison of cardiac output measurement in critical patients using transesophageal Doppler or thermodilution: a preliminary report]. Andresen M, Henríquez M, Mercado M, Farías G, Castillo C, Benítez C, Dougnac A. Rev Med Chil; 2005 Jul 01; 133(7):761-6. PubMed ID: 16341381 [Abstract] [Full Text] [Related]
18. Comparison between two methods for cardiac output measurement in propofol-anesthetized dogs: thermodilution and Doppler. Lopes PC, Sousa MG, Camacho AA, Carareto R, Nishimori CT, Santos PS, Nunes N. Vet Anaesth Analg; 2010 Sep 01; 37(5):401-8. PubMed ID: 20712606 [Abstract] [Full Text] [Related]
19. The influence of acute pulmonary hypertension on cardiac output measurements: calibrated pulse contour analysis, transpulmonary and pulmonary artery thermodilution against a modified Fick method in an animal model. Kutter APN, Mosing M, Hartnack S, Raszplewicz J, Renggli M, Mauch JY, Hofer CK. Anesth Analg; 2015 Jul 01; 121(1):99-107. PubMed ID: 25742632 [Abstract] [Full Text] [Related]
20. Clinical monitoring of cardiac output assessed by transoesophageal echocardiography in anaesthetised dogs: a comparison with the thermodilution technique. Mantovani MM, Fantoni DT, Gimenes AM, de Castro JR, Flor PB, Ida KK, Schwartz DS. BMC Vet Res; 2017 Nov 09; 13(1):325. PubMed ID: 29121915 [Abstract] [Full Text] [Related] Page: [Next] [New Search]