These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
224 related items for PubMed ID: 3948397
1. Bilirubin interference with determination of uric acid, cholesterol, and triglycerides in commercial peroxidase-coupled assays, and the effect of ferrocyanide. Spain MA, Wu AH. Clin Chem; 1986 Mar; 32(3):518-21. PubMed ID: 3948397 [Abstract] [Full Text] [Related]
2. Single-cuvet sequential determination of triglyceride and cholesterol. Zoppi F. Clin Chem; 1985 Dec; 31(12):2036-9. PubMed ID: 4064295 [Abstract] [Full Text] [Related]
3. The application of a sensitive uricase-peroxidase couple reaction to a centrifugal fast analyser for the determination of uric acid. Artiss JD, Entwistle WM. Clin Chim Acta; 1981 Nov 11; 116(3):301-9. PubMed ID: 7296893 [Abstract] [Full Text] [Related]
4. Bovine blood serum as a substitute for human serum for quality control of the determination of cholesterol and triglyceride. Moinuddin M, Witter RF, Quist KD. Clin Chim Acta; 1972 Mar 11; 37():123-30. PubMed ID: 5022075 [No Abstract] [Full Text] [Related]
5. Empirical relations as interference correctives in multichannel analyzers. Bokelund H. Clin Chim Acta; 1975 Apr 02; 60(1):7-13. PubMed ID: 1126032 [Abstract] [Full Text] [Related]
6. Dipyrone interference on several common biochemical tests. Gascón N, Otal C, Martínez-Brú C, Mercé J, Cortés M, Arcelus R, Queraltó JM, Sánchez JM, González-Sastre F. Clin Chem; 1993 Jun 02; 39(6):1033-6. PubMed ID: 8504533 [Abstract] [Full Text] [Related]
7. Interference with the enzymic measurement of cholesterol in serum by use of five reagent kits. Pesce MA, Bodourian SH. Clin Chem; 1977 Jun 02; 23(4):757-60. PubMed ID: 844175 [Abstract] [Full Text] [Related]
8. Enzymic serum cholesterol measurement with a basic autoanalyzer and Du Pont aca method. Fingerhut B. Clin Chem; 1978 Sep 02; 24(9):1624-7. PubMed ID: 688628 [Abstract] [Full Text] [Related]
9. Elimination of the "chromogen oxidase" activity of bilirubin oxidase added to obviate bilirubin interference in hydrogen peroxide/peroxidase detecting systems. Maguire GA. Clin Chem; 1985 Dec 02; 31(12):2007-8. PubMed ID: 2998643 [Abstract] [Full Text] [Related]
10. Effects of serum bilirubin on determination of uric acid by the uricase-peroxidase coupled reaction. Aoki Y, Ihara H, Nakamura H, Aoki T, Yoshida M. Clin Chem; 1992 Jul 02; 38(7):1350-2. PubMed ID: 1320471 [Abstract] [Full Text] [Related]
11. User-defined serum aspartate and alanine aminotransferase, cholesterol, triglycerides, urea, and uric acid for the Beckman synchron CX 4/5 using Ames Sera-Pak reagents. Lolekha PH, Nitipaichit P. J Clin Lab Anal; 1992 Jul 02; 6(5):245-56. PubMed ID: 1403344 [Abstract] [Full Text] [Related]
12. Determination of uric acid with uricase and peroxidase. Sanders GT, Pasman AJ, Hoek FJ. Clin Chim Acta; 1980 Feb 28; 101(2-3):299-303. PubMed ID: 7357749 [Abstract] [Full Text] [Related]
13. A method for the sequential colorimetric determination of serum triglycerides and cholesterol. Sharma A, Artiss JD, Zak B. Clin Biochem; 1987 Jun 28; 20(3):167-72. PubMed ID: 3652437 [Abstract] [Full Text] [Related]
14. Effect of bilirubin on uricase-peroxidase coupled reactions. Implications for urate measurement in clinical samples and external quality assessment schemes. Hullin DA, McGrane MT. Ann Clin Biochem; 1991 Jan 28; 28 ( Pt 1)():98-100. PubMed ID: 2024944 [Abstract] [Full Text] [Related]
15. [Emerson-Trinder reaction: study of various chromogens and analyses of the principle interferences (author's transl)]. Fossati P, Prencipe L. Quad Sclavo Diagn; 1978 Jun 28; 14(2):164-77. PubMed ID: 751094 [Abstract] [Full Text] [Related]
16. Interference by analgesic and antirheumatic drugs in 25 common laboratory assays. Jelić-Ivanović Z, Majkić-Singh N, Spasić S, Todorović P, Zivanov-Stakić D. J Clin Chem Clin Biochem; 1985 May 28; 23(5):287-92. PubMed ID: 3874926 [Abstract] [Full Text] [Related]
17. Effects of bilirubin on detection of hydrogen peroxide by use of peroxidase. Witte DL, Brown LF, Feld RD. Clin Chem; 1978 Oct 28; 24(10):1778-82. PubMed ID: 699289 [Abstract] [Full Text] [Related]
18. Spectrophotometry of carnitine in biological fluids and tissue with a Cobas Bio centrifugal analyzer. Cederblad G, Harper P, Lindgren K. Clin Chem; 1986 Feb 28; 32(2):342-6. PubMed ID: 3943195 [Abstract] [Full Text] [Related]
19. Therapeutic concentrations of hydroxocobalamin interferes with several spectrophotometric assays on the Beckman Coulter DxC and AU680 chemistry analyzers. Ranjitkar P, Greene DN. Clin Chim Acta; 2015 Oct 23; 450():110-4. PubMed ID: 26232160 [Abstract] [Full Text] [Related]
20. The influence of bilirubin, haemolysis and turbidity on 20 analytical tests performed on automatic analysers. Results of an interlaboratory study. Grafmeyer D, Bondon M, Manchon M, Levillain P. Eur J Clin Chem Clin Biochem; 1995 Jan 23; 33(1):31-52. PubMed ID: 7756439 [Abstract] [Full Text] [Related] Page: [Next] [New Search]